• Title/Summary/Keyword: Center Position

Search Result 3,340, Processing Time 0.041 seconds

A Comparative Study of the Effects of Proprioceptive Neuromuscular Facilitation and Taping Interventions on Balance Ability, Joint Position Sense, and Ankle Joint Strength (발목관절 근력과 관절위치감각, 그리고 균형능력에 미치는 고유수용성 신경근 촉진법 중재와 테이핑 중재 비교연구)

  • Kim, Jwa-jun;Park, Se-Yeon
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.51-58
    • /
    • 2018
  • Purpose: The aim of the present study was to investigate the effects of proprioceptive neuromuscular facilitation (PNF) and taping interventions on balance ability, joint position sense, and ankle joint strength. Methods: Thirty subjects who had experienced an ankle sprain within the previous 3 months participated in this study. The subjects were randomly assigned to a PNF group (n=15) or a taping group (n=15). Before and after the interventions, ankle dorsi-flexion and plantar-flexion strength, joint position error, and total center of pressure movements in one leg while in a standing position were measured. Results: Regardless of the group allocation, ankle dorsi-flexion and plantar-flexion strength significantly improved after the interventions (p<0.05). Compared to preintervention measurements, joint position errors were significantly reduced postintervention (p<0.05). The PNF intervention significantly decreased the total lateral movement of the center of pressure in the one leg standing condition (p<0.05). Conclusion: Both PNF and taping interventions improved joint position sense and ankle joint strength. In common with the findings of a previous study, the PNF intervention improved balance ability. Further study is required to investigate the effects of various PNF and taping interventions on ankle performance in subjects with chronic ankle sprains.

Wafer Position Sensing and Control in the Clean Tube System (클린 튜브 시스템에서 웨이퍼의 위치 인식 및 정지 제어)

  • Kim, Yu-Jin;Shin, Dong-Hun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.11
    • /
    • pp.1095-1101
    • /
    • 2006
  • The clean tube system was developed as a means of transferring air-floated wafers inside a closed tube filled with super clean air. This paper presents a wafer position sensing method in the clean tube system, where the photo proximity sensors are used. The first presented method uses the two positions sensed lately in order to compute the wafer center position. The next method uses the latest sensed position and the next latest position compensated with the information of the wafer velocity. The third method uses the kalman filter, which enable us to use all the previous sensing information. The simulation results are compared to show results of the presented method. In addition, the paper presents a control method to stop the wafer at the center of the unit in the clean tube system. The experimental clean tube system worked successfully with the applying the both presented methods of sensing and control.

MULTI-SENSOR DATA FUSION FOR FUTURE TELEMATICS APPLICATION

  • Kim, Seong-Baek;Lee, Seung-Yong;Choi, Ji-Hoon;Choi, Kyung-Ho;Jang, Byung-Tae
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.4
    • /
    • pp.359-364
    • /
    • 2003
  • In this paper, we present multi-sensor data fusion for telematics application. Successful telematics can be realized through the integration of navigation and spatial information. The well-determined acquisition of vehicle's position plays a vital role in application service. The development of GPS is used to provide the navigation data, but the performance is limited in areas where poor satellite visibility environment exists. Hence, multi-sensor fusion including IMU (Inertial Measurement Unit), GPS(Global Positioning System), and DMI (Distance Measurement Indicator) is required to provide the vehicle's position to service provider and driver behind the wheel. The multi-sensor fusion is implemented via algorithm based on Kalman filtering technique. Navigation accuracy can be enhanced using this filtering approach. For the verification of fusion approach, land vehicle test was performed and the results were discussed. Results showed that the horizontal position errors were suppressed around 1 meter level accuracy under simulated non-GPS availability environment. Under normal GPS environment, the horizontal position errors were under 40㎝ in curve trajectory and 27㎝ in linear trajectory, which are definitely depending on vehicular dynamics.

A Numerical Study of the Combustion Characteristics in a MILD Combustor with the Change of the Fuel and Air Nozzle Position and Air Mass Flow Rate (연료 및 공기 노즐 위치와 공기 유량 변화에 따른 MILD 연소 특성에 관한 해석적 연구)

  • Kim, Tae-Kwon;Shim, Sung-Hoon;Chang, Huyk-Sang;Ha, Ji-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.325-331
    • /
    • 2011
  • A numerical analysis of reactive flow in a MILD(Moderate and Intense Low oxygen Dilution) combustor is accomplished to elucidate the characteristics of combustion phenomena in the furnace with the change of fuel and air nozzle position and air mass flow rate. For the case with the fuel nozzle located near center position of combustor, the reaction zone started at the fuel nozzle and had inclined shape toward combustor wall when the air mass flow rate was relatively smaller. On the other hand, the end of reaction zone moved toward center of combustor from combustor wall when the air flow rate was relatively larger. For the case with the air nozzle located near center position of combustor, the reaction zone started at the fuel nozzle and had inclined shape toward combustor wall when the air mass flow rate was relatively small, which was similar as the previous case with smaller air mass flow rate. On the other hand, the end of reaction zone moved toward combustor wall when the air flow rate was relatively larger. The maximum temperature increased as the air mass flow rate increasing for both cases, and the concentration of thermal NOx increased also from the previous reason of temperature characteristics. The concentration of NOx for the case with the air nozzle located near center position of combustor was considerably smaller than that for the case with the fuel nozzle located near center position of combustor. From the present study, the case with the air nozzle located near center position of combustor and theoretical air flow rate was the most effective condition for the NOx reduction and perfect combustion.

Initial Pole Position Estimation of Surface PM-LSM

  • Kim, Tae-Woong;Junichi Watanabe;Sumitoshi Sonoda;Junji Hirai
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • The elimination of a pole sensor is desirable due to the low-cost requirement, the compactness, and the applied drives. This paper proposes the algorithm for the initial pole-position estimation of a surface permanent magnet linear synchronous motor (PM-LSM), which is carried out under the closed loop control without a pole sensor and is insensitive to the motor parameters. This algorithm is based on the principle that the initial pole position (IPP) is estimated by the trigonometric function of the two reference currents. The effectiveness of the proposed algorithm is confirmed by testing a surface PM-LSM with large disturbance, which result shows that IPP is well estimated within a satisfied moving-distance and a shorter estimation taken-time even if large disturbance such as cogging and friction is existed.

  • PDF

Autonomous Sensor Center Position Calibration with Linear Laser-Vision Sensor

  • Jeong, Jeong-Woo;Kang, Hee-Jun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • A linear laser-vision sensor called ‘Perception TriCam Contour' is mounted on an industrial robot and often used for various application of the robot such as the position correction and the inspection of a part. In this paper, a sensor center position calibration is presented for the most accurate use of the robot-Perceptron system. The obtained algorithm is suitable for on-site calibration in an industrial application environment. The calibration algorithm requires the joint sensor readings, and the Perceptron sensor measurements on a specially devised jig which is essential for this calibration process. The algorithm is implemented on the Hyundai 7602 AP robot, and Perceptron's measurement accuracy is increased up to less than 1.4mm.

Merit of Zone III Resuscitative Endovascular Occlusion of the Aorta under Real-Time Fluoroscopy in Hybrid ER: A Case of REBOA in Traumatic Cardiac Arrest

  • Lee, Sung Do;Chung, Seungwoo;Ki, Young Jun;Seo, Sang Hyun;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • v.33 no.3
    • /
    • pp.191-194
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a novel technique to maintain proximal arterial pressure. It is important to locate the balloon catheter correctly in performing REBOA but it is inaccurate to check the catheter position by external measurement. Even if the position of the catheter is initially confirmed by X-ray, it is difficult to determine the location of the catheter that changes according to various situations. We performed REBOA under real-time fluoroscopy and could maintain the catheter in correct position under various situations.

Displacement-Type Web Position Control of Cold Mills Using QFT (QFT를 이용한 냉간 압연시스템의 변위유도형 웹 위치제어)

  • Jeong, Jae-Hyo;Kim, Jong-Sik;Park, Jeon-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.147-155
    • /
    • 2001
  • A new displacement type web position control system for cold mills using QFT is presented. The control system features an inner-outer cascaded system in which the inner loop provides the position tracking control of the hydraulic system and the outer loop provides the position regulation control of the web. By the sensitivity analysis and computer simulation, it is verified that the proposed control system has better robust stability and performance than the conventional control system.

  • PDF

DEVELOPMENT OF POSITION-SENSITIVE PROTON RECOIL TELESCOPE (PSPRT)

  • Miura, Takako;Baba, Mamoru;Kawata, Naoki;Sanami, Toshiya
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.161-165
    • /
    • 2001
  • We have developed a position-sensitive proton recoil telescope (PSPRT) which employs a position-sensitive photomultiplier (PS-PMT) and a scintillator for both a radiator and a proton-detector. This system is expected to achieve high energy resolution under a large solid angle, because it enables to obtain the information not only on the proton energy but also the recoil angle from the position data for both detectors. The response of the PSPRT for 14.1 MeV mono-energetic neutrons was measured, and the PSPRT proved to be operating as expected.

  • PDF

The Respiratory and Hemodynamic Effect of Prone Position in Patients with ARDS (급성호흡부전증후군에서 Prone Position의 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Koh, Youn-Suck;Jung, Bok-Hyun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1105-1113
    • /
    • 1997
  • Background : Prone position improves oxygenation in some patients with ARDS. According to some authors, prone position can also improve the deteriorated hemodynamics induced by PEEP. But these respiratory and hemodynamic effects of prone position has not yet been fully established. Methods : Twentythree consequtive patients with ARDS(M : F= 11 : 12, $62.1{\pm}20.8yrs$) were the subjects for this study. ABGA, static compliance of the respiratory system, mean arterial pressure and pulse rate were obtained in supine position and at 5min, 0.5h and 2h of prone position. Positive respiratory response was defined as 20mmHg or more increase in $PaO_2/FIO_2$ within 2h of prone position. Early of late respiratory responses were defined if the positive response was observed within of after 3 day of ARDS onset, respectively. Positive hemodynamic response was defined as 10mmHg or more increase in mean arterial pressure at 5min of prone position. Results : Fifteen patients (65%) showed positive respiratory response. In the respiratory responders, $PaO_2$ was $69.8{\pm}17.6mmHg$ in supine position, $83.2{\pm}22.6mmHg$ in prone position 0.5h, $96.8{\pm}22.7mmHg$ in prone position 2h(p<0.001), and $PaO_2/FIO_2$ was $108{\pm}41mmHg$, $137{\pm}57mmHg$, $158{\pm}50mmHg$, respectively(p=0.001). Age, sex, cause of ARDS, supine $PaO_2$ and $PaO_2/FIO_2$ were not different between the respiratory responders and the nonresponders. The respiratory responders, however, showed higher mean arterial pressure than the nonresponders($91.1{\pm}13.1mmHg$ vs. $76.0{\pm}18.7mmHg$, p=0.035), and tendency of higher survival rate(9/15 vs. 2/8, p=0.074). Static compliance of the respiratory system was decreased in prone position 0.5h($28.4{\pm}7.9ml/cm$ $H_2O$ vs. $23.8{\pm}7.6ml/cm$ $H_2O$, p=0.007). The overall rate of early response(n=23) and late response(n=11) were similar(14/23 vs. 7/11, p>0.05). But patient without early response showed late response only in 25%(1/4), while patient with early response showed late response in 85.7%(6/7)(p=0.072). Five patients(22%) showed positive hemodynamic response, two of them being respiratory nonresponders. There were no differences in the baseline mean arterial pressure or the level of PEEP applied in supine between the hemodynamic responders and the hemodynamic nonresponders. Conclusions : Prone position either improved oxygenation or increased arterial pressure in significant proportion of patients with ARDS. And the respiratory response to prone position was thought to be determined in the early stage of ARDS.

  • PDF