• Title/Summary/Keyword: Center Error

Search Result 2,542, Processing Time 0.032 seconds

A study on improvement of misdiagnosis rate in aortic regurgitation disease by physically correcting EF in 2D echo cardiography (대동맥판 역류질환 진단시 이면성심초음파 박출계수의 보정을 통한 오진율 개선에 관한 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2142-2147
    • /
    • 2012
  • This study is aimed at decreasing wrong diagnosis with corrected EF(Ejection Fraction) of 2D echo cardiography by analysing the physical time-resolution difference between Cine MRI and 2D echo cardiography and applying the corrected EF in 2D echocardiography. From February 2010 to December 2011, among the 110 patients who had undergone both 2D echo cardiography and cine MRI only 37 patient were selected suffering aortic valve regurgitation. ED, ES and SV were measured and EF was calculated in each system while normal ranges of Cine MRI and 2D echocardiography were compared to evauate misdiagnosis rate. The correlation of physical time resolution between 2D echocardiography and MRI was evaluated and the differences were corrected with linear regression coefficient which is derived from linear regression analysis. Blandt-Altman plot was used to evaluate the reliability of corrected 2D echo cardiography EF and compare the error among measured values. The values were compared with MRI normal range and misdiagnosis rate was measured again. As a result, misdiagnosis rates of physical time resolution were measured to be 32.4%(12people) before the correction of EF and 18.9%(7people) after the correction. Also, EF confirmed in Blandt-Altman plot were almost the same with MRI EF. In conclusion, when diagnosing aortic regurgitation disease, simply using 2D echocardiography can easily raise the misdiagnosis rates, therefore considering the MRI machine's physical merits, correcting the time resolution difference is important by calculating time resolution wrong diagnosis would decrease and it is considered to be useful in clinical circumstances.

Three Crystal Structures of Dehydrated Partially $Co^{2+}-Exchanged$ Zeolite A Treated with Potassium Vapor (부분적으로 코발트 이온으로 치환한 제올라이트 A를 진공 탈수한 후 칼륨 증기로 반응시킨 3개의 결정구조)

  • Jeong Mi Suk;Jang Se Bok
    • Korean Journal of Crystallography
    • /
    • v.15 no.2
    • /
    • pp.59-68
    • /
    • 2004
  • Three crystal structures of dehydrated partially $Co^{2+}-exchanged$ zeolite A treated with 0.6 Torr of K at $300^{\circ}C$ (for 12 hrs, 6 hrs, and 2 hrs) vapor have been determined by single-crystal X-ray diffraction techniques in the cubic space group Pm3m at 21(1)$^{\circ}C(a=12.181(1)\;{\AA},\;a=12.184(1)\;{\AA},\;and\;a=12.215(1)\;{\AA})\;respectively)$. Their structures were refined to the final error indices, R(weight) of 0.090 with 10 reflections, 0.091 with 82 reflections, and 0.090 with 80 reflections, respectively, for which $1>\sigma(I)$. In each structure, all four $Co^{2+}$ and four $Na^+$ ions to be reduced by K atoms. The cobalt and sodium atoms produced are no longer found in the zeolite. K species are found at five different crystallographic sites: three $K^+$ ions lie at the planes of 8-rings, filling that position, ca. 11.5 K^+$ ions lie on threefold axes, ca. 4.0 in the large cavity and ca. 4.0 in the sodalite cavity, and ca. 0.5 $K^+$ ion is found near a 4-ring. ca. three $K^0$ atoms are found deep into the large cavity on threefold axes. In these structures, crystallographic results show that cationic tetrahedral $K_4$ (and/or triangular $K_3$) clusters have formed in the sodalites of zeolite A. The $K_4$ and/or $K_3$ clusters coordinate trigonally to three oxygens of a six-oxygen ring. The partially reduced ions of these clusters interact primarily with oxygen atoms of the zeolite structure rather than with each other. ca. 14.5K species are found per unit cell, more than the twelve $K^+$ ions needed to balance the anionic charge of zeolite framework, indicating that sorption of $K^0$ has occurred. The three $K^0$ atoms in the large cavity are closely associated with three out of four $K^+$ ions in the large cavity to form $K_7^{4+}$ clusters. The $K_7^{4+}$ cluster not interacts primarily with framework oxygens.

Statistical Errors in Papers Published in the Journal of the Korean Society for Therapeutic Radiology and Oncology (대한방사선종양학회지 게재 논문의 통계적 오류 현황)

  • Park, Hee-Chul;Choi, Doo-Ho;Ahn, Song-Vogue;Kang, Jin-Oh;Kim, Eun-Seog;Park, Won;Ahn, Seung-Do;Yang, Dae-Sik;Yun, Hyong-Geun;Chung, Eun-Ji;Chie, Eui-Kyu;Pyo, Hong-Ryull;Hong, Se-Mie
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.289-294
    • /
    • 2008
  • Purpose: To improve the quality of the statistical analysis of papers published in the Journal of the Korean Society for Therapeutic Radiology and Oncology (JKOSTRO) by evaluating commonly encountered errors. Materials and Methods: Papers published in the JKOSTRO from January 2006 to December 2007 were reviewed for methodological and statistical validity using a modified version of Ahn's checklist. A statistician reviewed individual papers and evaluated the list items in the checklist for each paper. To avoid the potential assessment error by the statistician who lacks expertise in the field of radiation oncology; the editorial board of the JKOSTRO reviewed each checklist for individual articles. A frequency analysis of the list items was performed using SAS (version 9.0, SAS Institute, NC, USA) software. Results: A total of 73 papers including 5 case reports and 68 original articles were reviewed. Inferential statistics was used in 46 papers. The most commonly adopted statistical methodology was a survival analysis (58.7%). Only 19% of papers were free of statistical errors. Errors of omission were encountered in 34 (50.0%) papers. Errors of commission were encountered in 35 (51.5%) papers. Twenty-one papers (30.9%) had both errors of omission and commission. Conclusion: A variety of statistical errors were encountered in papers published in the JKOSTRO. The current study suggests that a more thorough review of the statistical analysis is needed for manuscripts submitted in the JKOSTRO.

A Real-Time Head Tracking Algorithm Using Mean-Shift Color Convergence and Shape Based Refinement (Mean-Shift의 색 수렴성과 모양 기반의 재조정을 이용한 실시간 머리 추적 알고리즘)

  • Jeong Dong-Gil;Kang Dong-Goo;Yang Yu Kyung;Ra Jong Beom
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • In this paper, we propose a two-stage head tracking algorithm adequate for real-time active camera system having pan-tilt-zoom functions. In the color convergence stage, we first assume that the shape of a head is an ellipse and its model color histogram is acquired in advance. Then, the min-shift method is applied to roughly estimate a target position by examining the histogram similarity of the model and a candidate ellipse. To reflect the temporal change of object color and enhance the reliability of mean-shift based tracking, the target histogram obtained in the previous frame is considered to update the model histogram. In the updating process, to alleviate error-accumulation due to outliers in the target ellipse of the previous frame, the target histogram in the previous frame is obtained within an ellipse adaptively shrunken on the basis of the model histogram. In addition, to enhance tracking reliability further, we set the initial position closer to the true position by compensating the global motion, which is rapidly estimated on the basis of two 1-D projection datasets. In the subsequent stage, we refine the position and size of the ellipse obtained in the first stage by using shape information. Here, we define a robust shape-similarity function based on the gradient direction. Extensive experimental results proved that the proposed algorithm performs head hacking well, even when a person moves fast, the head size changes drastically, or the background has many clusters and distracting colors. Also, the propose algorithm can perform tracking with the processing speed of about 30 fps on a standard PC.

Name Review, and Production Method of Pyeongjeongmo, Housed by the National Palace Museum of Korea (국립고궁박물관 소장 평정모(平頂帽)의 명칭 검토와 제작방법)

  • Lee, Eun-Joo;Jin, Duk-Soon;Lee, Jeong-Min
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.2
    • /
    • pp.4-21
    • /
    • 2018
  • This paper reviewed the legitimacy of the name of those sixteen pieces of hat artifacts known in Korean as pyeongjeongmo and currently housed by the National Palace Museum. This was undertaken in order to rectify the error of calling them pyeongjeongmo. Also, the paper suggested pyeongjeongmo's production method to apply representation of the artifacts or production of Joseon officials' hats as representation of ritual costumes in the royal court. The name pyeongjeongmo originated from pyeongjeonggeon. Gyeongguk Daejeon recorded that noksas wore yugak-pyeongjeonggeon and seoris wore mugak-pyeongjeonggeon, but the pyeongjeongmo artifacts housed in the National Palace Museum have been found irrelevant to those pyeongjeonggeons put on by both noksas and seoris. Rather, they has been confirmed as corresponding to dugeon or jogeon worn by byeolgams or suboks who served at the palace of the crown prince or princess. Through the investigation of the artifacts, the researchers could find out the tailoring and sewing methods, the finished look, and the folding manner of pyeongjeonggeon. Although the structure of pyeongjeonggeon was generally consistent, the frontal look was slightly different depending on the folding manner, resulting in three distinguished types of pyeongjeonggeon. Regardless, the pyeongjeongmo was made with one piece of fabric by a flat tailoring and folding method to create a three-dimensional hat. The finished shape appeared low in the front and high in the back side structure. The head girth was 55~59 cm, and the height was 19.4~21.5 cm. To make it with one piece of fabric, the head girth part was tailored in the same direction as the strands. Based on the artifact Changdeok 23820, this paper has also suggested a finished reproduction through the processes of preparing the materials, mounting, making the center ornaments, sewing and folding. The tailoring was completed with black silk fabric which was cut in a unique shape designed in advance, and hemp fabric which was mounted to the former. The top part of the head was finished with black threads, and the center line at the back was fixed with decolored cotton threads by blanket stitches with 3.5~4 cm intervals. Bamboo strands were inserted in the inside of the front-folded part, which then was fixed by patterned stitches with white cotton thread. At the back, a small bamboo clasp was attached so that one can lock it to the headband and prevent it from falling off.

Development of a Retrieval Algorithm for Adjustment of Satellite-viewed Cloudiness (위성관측운량 보정을 위한 알고리즘의 개발)

  • Son, Jiyoung;Lee, Yoon-Kyoung;Choi, Yong-Sang;Ok, Jung;Kim, Hye-Sil
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.415-431
    • /
    • 2019
  • The satellite-viewed cloudiness, a ratio of cloudy pixels to total pixels ($C_{sat,\;prev}$), inevitably differs from the "ground-viewed" cloudiness ($C_{grd}$) due to different viewpoints. Here we develop an algorithm to retrieve the satellite-viewed, but adjusted cloudiness to $C_{grd} (C_{sat,\;adj})$. The key process of the algorithm is to convert the cloudiness projected on the plane surface into the cloudiness on the celestial hemisphere from the observer. For this conversion, the supplementary satellite retrievals such as cloud detection and cloud top pressure are used as they provide locations of cloudy pixels and cloud base height information, respectively. The algorithm is tested for Himawari-8 level 1B data. The $C_{sat,\;adj}$ and $C_{sat,\;prev}$ are retrieved and validated with $C_{grd}$ of SYNOP station over Korea (22 stations) and China (724 stations) during only daytime for the first seven days of every month from July 2016 to June 2017. As results, the mean error of $C_{sat,\;adj}$ (0.61) is less that than that of $C_{sat,\;prev}$ (1.01). The percent of detection for 'Cloudy' scenario of $C_{sat,\;adj}$ (73%) is higher than that of $C_{sat,\;prev}$ (60%) The percent of correction, the accuracy, of $C_{sat,\;adj}$ is 61%, while that of $C_{sat,\;prev}$ is 55% for all seasons. For the December-January-February period when cloudy pixels are readily overestimated, the proportion of correction of $C_{sat,\;adj$ is 60%, while that of $C_{sat,\;prev}$ is 56%. Therefore, we conclude that the present algorithm can effectively get the satellite cloudiness near to the ground-viewed cloudiness.

Estimation of Stem Taper Equations and Stem Volume Table for Phyllostachys pubescens Mazel in South Korea (맹종죽의 수간곡선식 및 수간재적표 추정)

  • Eun-Ji, Bae;Yeong-Mo, Son;Jin-Taek, Kang
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.4
    • /
    • pp.622-629
    • /
    • 2022
  • The study aim was to derive a stem taper equation for Phyllostachys pubescens, a type of bamboo in South Korea, and to develop a stem volume table. To derive the stem taper equation, three stem taper models (Max & Burkhart, Kozak, and Lee) were used. Since bamboo stalks are hollow because of its woody characteristics, the outer and inner diameters of the tree were calculated, and connecting them enabled estimating the tree curves. The results of the three equations for estimating the outer and inner diameters led to selection of the Kozak model for determining the optimal stem taper because it had the highest fitness index and lowest error and bias. We used the Kozak model to estimate the diameter of Phyllostachys pubescens by stem height, which proved optimal, and drew the stem curve. After checking the residual degree in the stem taper equation, all residuals were distributed around "0", which proved the suitability of the equation. To calculate the stem volume of Phyllostachys pubescens, a rotating cube was created by rotating the stem curve with the outer diameter at 360°, and the volume was calculated by applying Smalian's method. The volume of Phyllostachys pubescens was calculated by deducting the inner diameter calculated volume from the outer diameter calculated volume. The volume of Phyllostachys pubescens was only 20~30% of the volume of Larix kaempferi, which is a general species. However, considering the current trees/ha of Phyllostachys pubescens and the amount of bamboo shoots generated every year, the individual tree volume was predicted to be small, but the volume/ha was not very different or perhaps more. The significance of this study is the stem taper equation and stem volume table for Phyllostachys pubescens developed for the first time in South Korea. The results are expected to be used as basic data for bamboo trading that is in increasing public and industrial demand and carbon absorption estimation.

Rice Yield Estimation Using Sentinel-2 Satellite Imagery, Rainfall and Soil Data (Sentinel-2 위성영상과 강우 및 토양자료를 활용한 벼 수량 추정)

  • KIM, Kyoung-Seop;CHOUNG, Yun-Jae;JUN, Byong-Woon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.1
    • /
    • pp.133-149
    • /
    • 2022
  • Existing domestic studies on estimating rice yield were mainly implemented at the level of cities and counties in the entire nation using MODIS satellite images with low spatial resolution. Unlike previous studies, this study tried to estimate rice yield at the level of eup-myon-dong in Gimje-si, Jeollabuk-do using Sentinel-2 satellite images with medium spatial resolution, rainfall and soil data, and then to evaluate its accuracy. Five vegetation indices such as NDVI, LAI, EVI2, MCARI1 and MCARI2 derived from Sentinel-2 images of August 1, 2018 for Gimje-si, Jeollabuk-do, rainfall and paddy soil-type data were aggregated by the level of eup-myon-dong and then rice yield was estimated with gamma generalized linear model, an expanded variant of multi-variate regression analysis to solve the non-normality problem of dependent variable. In the rice yield model finally developed, EVI2, rainfall days in September, and saline soils ratio were used as significant independent variables. The coefficient of determination representing the model fit was 0.68 and the RMSE for showing the model accuracy was 62.29kg/10a. This model estimated the total rice production in Gimje-si in 2018 to be 96,914.6M/T, which was very close to 94,470.3M/T the actual amount specified in the Statistical Yearbook with an error of 0.46%. Also, the rice production per unit area of Gimje-si was amounted to 552kg/10a, which was almost consistent with 550kg/10a of the statistical data. This result is similar to that of the previous studies and it demonstrated that the rice yield can be estimated using Sentinel-2 satellite images at the level of cities and counties or smaller districts in Korea.

Morphological Characteristics, and Coefficient of Variation, Heritability and Genetic Advance of Major Cultivars of Spray Chrysanthemum (주요 스프레이 국화 품종의 형태적 특성과 변이계수, 유전율 및 유전자 전이율)

  • Shim, Sung-Im;Lim, Ki-Byung;Kim, Chang-Kil;Chung, Mi-Young;Kim, Kyung-Min;Chung, Jae-Dong
    • Horticultural Science & Technology
    • /
    • v.34 no.2
    • /
    • pp.269-281
    • /
    • 2016
  • The statistical analyses of coefficient of variation, heritability, and genetic advance were carried out to identify differences in morphological characteristics, such as the stem and inflorescence length, of 10 major commercial cultivars of spray chrysanthemum (Chrysanthemum morifolium). For morphological characteristics, stem lengths ranged from 46.4 cm to 54.9 cm, the maximum diameter of stem was 5.6 to 8.5 mm, the hardness of the stem was 0.17 to $0.70kg{\cdot}m^{-2}$, the fresh weight of stem was 7.5 to 17.5 g, the dry weight of the stem was 1.6 to 3.3 g, the ratio of dry weight/fresh weight of stem was 15.9% to 23.1%. Also, the number of leaves on the stem was 8.4 to 12.2, the stem leaf area was 17.8 to $37.8m^2$, the fresh weight stem leaves was 5.3 to 18.6 g, the dry weight was 0.5 to 1.4 g and the ratio of dry weight /fresh weight of stem leaves was 7.6% to 11.5%. The inflorescence length ranged from 10.1 to 18.6 cm, the fresh weight of inflorescence was 7.3 to 26.7 g, the dry weight of inflorescence was 1.2 to 2.8 g, the ratio of dry weight /fresh weight of inflorescence was 10.4% to 17.1%. For flower, the diameter of the flower center was 8.2 to 13.3 mm, the petal width was 5.7 to 14.0 mm, the petal length was 12.9 to 33.1 mm, and the petal thickness was 157.8 to $354.4{\mu}m$. The mean values of each character in each cultivar were very different, and DMRT and LSD values based on morphological characteristics among 10 cultivars were highly significant. For variability and genetic parameters, the lowest CV (coefficient of variation), PCV (phenotypic coefficient of variation), and GCV (genotypic coefficient of variation) were 4.79% to 5.15% in stem length, and the highest variations were 62.97% to 65.21% in leaf area. ECV (error or environmental coefficient of variation) was the lowest for leaf area (1.71%) and it was the highest for leaf dry weight (19.30%). Heritability also significantly differed among the characteristics, ranging from 68.69% to 99.67%, the lowest value was shown in ratio of dry weight /fresh weight of stem and the highest value was for leaf area of stem. The value for genetic advance was the lowest in hardness of stem at 0.30 and the highest in leaf thickness at 156.65. The lowest genetic advance as percentage of mean of stem hardness was 9.17%, while the highest percentage of stem length was 134.27%. Thus the characters which had the highest values indicated above show the influence of additive gene action and may provide useful resources for selection programs for agronomic improvement.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF