• 제목/요약/키워드: Cement replacement

검색결과 777건 처리시간 0.029초

고로슬래그 미분말 대체율에 따른 콘크리트의 공학적 특성에 관한 실험적 연구 (An Experimental Study on the Engineering Properties of Concrete According to the Replacement Ratio of Blast-Furnace Slag)

  • 송민섭;장재봉;김갑수;윤종기;김재환;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.5-8
    • /
    • 2003
  • As a part of efforts to obtain high quality and economical of efficiency of concrete, blast-furnace slag has been utilized by means of cement replacement. Therefore superior performance can be ensured, environmental pollution can be prevented and economical advantage can be obtained with utilization by cement replacement. But the studies on the blast-furnace slag are not systematic and reasonable. So, it was planed that basic data in regard to technique of manufacturing and economic improvement of concrete is showed with experimental comparison and investigation of engineering properties of concrete utilizing blast-furnace, industry by-product, as cement replacement in this study.

  • PDF

결합재 종류 및 치환율 변화가 순환잔골재 사용 고로슬래그 모르타르의 품질에 미치는 영향 (Effect of Binder Types and Replacement ratio on the Properties of Blast Slag Mortar Using the Recycled Fine Aggregates)

  • 풍해동;박경택;백대현;김대건;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.77-78
    • /
    • 2011
  • This study is analysis of effect of binder types and replacement ratio on the properties of blast furnace slag mortar using the recycled fine aggregates. The results of the study were was follows. Compressive strength was increased according to an increase in replacement ratio of fine particle cement and gypsum. Absorption was reduced according to an increase in replacement ratio of fine particle cement and recycled aggregate fine powder.

  • PDF

고로슬래그 미분말 모르터에 시멘트 및 순환잔골재 치환율 변화에 따른 품질특성 (Effect of Partial Replacement with Cement and Recycled Fine Aggregate on Properties of Blast Furance Slag-Based Mortar)

  • 김영희;펑해동;손호정;이향재;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.215-216
    • /
    • 2011
  • This study investigates the effect of partial replacement with cement on the properties of blast furnace slag-based mortar. Recycled fine aggregate with various contents was used to activate the hydration of blast furnace slag in the mortar and compared its effect on strength development. Results showed that increasing cement and recycled fine aggregate increased the strength of mortar specimens. However, this study found that the mortar made with partial replacement of river sand with recycled fine aggregate of 20% developed a similar strength to the strength that cement with 10% can achieved.

  • PDF

Application of zeolite/kaolin combination for replacement of partial cement clinker to manufacture environmentally sustainable cement in Oman

  • Abdul-Wahab, Sabah A.;Hassan, Edris M.;Al-Jabri, Khalifa S.;Yetilmezsoy, Kaan
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.246-253
    • /
    • 2019
  • This study was conducted to explore the optimum proportion of zeolite and zeolite-kaolin as additives to cement clinker and gypsum samples, while maintaining the strength properties of produced environmentally sustainable cements. According to the British standard method, zeolite was added to cement clinker in proportions of 5-12% and 10-12% by weight, respectively, in the preparation of samples of zeolite-containing cement and zeolite-kaolin-based cement. Kaolin was used as a second additive as 10-20% of the total weight. The compressive strength tests were performed on base cement samples according to a standard procedure given in ASTM C109 Compressive Strength of Hydraulic Cement. These values were compared with those of the reference sample and the Omani allowable limits. The results indicated that the best compressive strength values were obtained with 88% cement clinker, 5% gypsum, and 7% zeolite for the zeolite-containing cement. Quantities of 70% cement clinker, 5% gypsum, 10% zeolite, and 15% kaolin gave the best results for zeolite-kaolin-based cement, resulting in a substitution of than 25% cement clinker. The study concluded that the partial cement clinker replacement using zeolite/kaolin combination may have a great influence on the reduction of $CO_2$ emission and energy saving in cement manufacturing.

Contribution of local materials and the recycling of slate in the constitution of hydraulic concrete pavements

  • Tedjeddine Bendisari;Lynda A. Chaabane;Feriel Tires;Assma L. Mazouzi;Wissam Y. Bouayed;Abderrahman Lalimi;Kadid Moufek
    • Advances in materials Research
    • /
    • 제12권4호
    • /
    • pp.287-308
    • /
    • 2023
  • The main objective of this article is to highlight the progress made in the development of new materials that have been gradually used by humans until today. Of course, this progress must be associated with other parameters in order to guarantee sustainable development. For this, today, it has become urgent to reduce the consumption of cement by resorting to its partial or total replacement by other similar materials in order to reduce CO2 emissions in our environment. This should certainly help to develop greener building materials. In this study, it was decided to proceed with the partial or total replacement of Portland cement type CEM II/B-L-42.5N by slate and lime that had not undergone any previous transformation. The results obtained revealed that the mortar whose substitution compared to the replacement of cement (100%) cement and sand (0/4) confers better kinetics than those of the series composed of(100%) cement and fraction rubble (0/1).

플라이애쉬를 대량 사용한 고강도 콘크리트에 관한 실험적 연구 (The Experimental Study on High Strength Concrete of High Volume Fly-Ash)

  • 이동하;서동훈;전판근;백민수;임남기;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.275-280
    • /
    • 2002
  • To study of high volume fly -ash concrete replace cement and fine aggregate together. Proportion consideration economy cost and performance improve replacement high volume fly-ash. Experimentation study of high-strength which cement about fly-ash replacement maximum 50%Flash concrete tested slump, air contest, setting and Hardening concrete tested day of age 1, 3, 7, 28, 91 compression strength in underwater curing. Purpose of study is consultation materials in field that variety of fly ash replacement concrete mix proportion comparison and valuation.

  • PDF

메타카올린 치환에 따른 알칼리-실리카 반응 팽창 저감효과 (The Effect of Meta-Kaolin Replacement on Alkali-Silica Reaction)

  • 전쌍순;이효민;진치섭;황진연
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.360-363
    • /
    • 2004
  • The effectiveness of Meta-Kaolin to prevent detrimental expansion due to alkali-silica reaction was investigated through the ASTM C 1260 method. Reactive aggregate used is a metamorphic rock. The replacement proportions of portland cement by Meta-Kaolin were 0, 5, 10, 15, 25 and 35 percent, respectively. The results indicate that 25 percent replacement of portland cement by Meta-Kaolin seems to be most effective to reduce alkali-silica reaction expansion under this experimental conditions.

  • PDF

Influence of Chemical Activators on Cement-Fly ash Paste and Strength Development of Concrete

  • Song, Jong-Taek;Yun, Sung-Dae;Kim, Jae-Young;Lee, Chin-Yong
    • The Korean Journal of Ceramics
    • /
    • 제6권2호
    • /
    • pp.103-106
    • /
    • 2000
  • The effects of replacement level, curing method and chemical admixtures were investigated in the cement-fly ash paste. The strength of cement-fly ash paste is lower than that of controlled cement paste only and the differences increase with replacement level. However, in steam curing, strength of cement-fly ash pastes is improved, especially, at early ages. In order to improve early strength, the use of $Na_2SO_4$in cement-fly ash paste increases the quality of concrete. In addition, improvement of strength of concrete including 30% of fly ash can be obtained and achieves the highest strength compared to other concrete mixtures.

  • PDF

분체의 종류에 따른 고유동 콘크리트의 품질성능에 관한 연구 (A study on the quality performances of the high flowing concrete for binder types)

  • 권영호;이현호;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.567-572
    • /
    • 2002
  • This research investigates experimentally an effect on the quality performances of the high flowing concrete according to binder types. The purpose of this study is to determine the optimum mix proportion of the high flowing concrete having good flowability, viscosity and no-segregation. For this purpose, two types using belite cement+lime stone powder(LSP) and furnace slag cement+lime stone powder are selected and tested by design factors including water cement ratio, fine and coarse aggregate volume ratio. As test results of this study, the optimum mix proportion for binder types is as followings. 1) One type based belite cement ; water cement ratio $51^{\circ}C$, fine aggregate volume ratio $43^{\circ}C$ and coarse aggregate volume ratio $53^{\circ}C$, replacement ratio of LSP $42.7^{\circ}C$. 2) Another type based slag cement : water cement ratio $41^{\circ}C$, fine aggregate volume ratio $47^{\circ}C$ and coarse aggregate volume ratio $53^{\circ}C$, replacement ratio of LSP $13.5^{\circ}C$.

  • PDF

Cementing Efficiency of Fly-ash in Mortar Matrix According to Binder-Water Ratio and Fly-ash Replacement Ratio

  • Cho, Hong-Bum;Jee, Nam-Yong
    • 한국건축시공학회지
    • /
    • 제12권2호
    • /
    • pp.194-202
    • /
    • 2012
  • This paper predicts the cementing efficiency of fly-ash(FA) based on mortar test considering binder-water ratio and FA replacement ratio as experimental variables. The cementing efficiency prediction model proposed by statistical analysis enables us to estimate the value according to the binder-water ratio and FA replacement ratio of matrix. When FA replacement ratio is the same, the lower the binder-water ratio, the higher the estimated cementing efficiency. There are significant differences in the values according to binder-water ratio at FA replacement ratios of 15% or less, but there are almost no differences when FA replacement ratio is more than 15%. As the binder-water ratio increases, the variations in the values according to FA replacement ratio are great at FA replacement ratios of 15% or less. As the FA replacement ratios increase, the values increase for FA replacement ratios of 15% or less, but decrease for more than 15%. The values range from -0.71 to 1.24 at binder-water ratio of 1.67-2.86 and FA replacement ratio of 0-70%. The RMSE of the 28-day compressive strength predicted by modified water-cement ratio is 2.2 MPa. The values can be trusted, as there is good agreement between predicted strength and experimental strength.