• Title/Summary/Keyword: Cell measurement

Search Result 1,599, Processing Time 0.034 seconds

Evaluation on the Usefulness of Filter in Sentinel Lymphoscintigraphy Using $^{99m}Tc$-Phytate (Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가)

  • Jeong, Yeong-Hwan;Seo, Han-Kyung;Shim, Cheol-Min;Lim, Seong-Dong;Han, Dong-Hyeon;Park, Yung-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2010
  • Purpose: The aim of this study was to investigate distribution of particle size in phytate kit and compare filtered method with non-filtered method using 200 nm filter for sentinel lymphoscintigraphy (SLS). Materials and Methods: Five phytate kit of having the same available period was measured by particle size analyzer. For in-vivo experiment, $^{99m}Tc$-phytate was injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired at 1hour after injection. Region of interest (ROI) was drawn in inguinal and background area for analysis. RAW 264.7 cells (Murine macrophage cell) were prepared for measurement of celluar uptake as a representative of macrophages. Paired t-test was performed using SPSS (SPSS Inc, USA) for statistical analysis. Results: The size of most particle in Techne phytate kit was distributed in 130~650 nm(90.5 %). In-vivo study, the ROI analysis showed similar result between filtered and non-filtered sample, and the numerical value of count/pixel were $58.3{\pm}5.97$ and $60.2{\pm}4.88$. In-vitro study, cellular uptake study also showed no difference between filtered and non-filtered sample by gamma counting. Conclusion: The present study demonstrates that there was no meaning of 200 nm filtered method for SLS using $^{99m}Tc$-phytate.

  • PDF

Changes of Serum Troponin-T Concentrations in Patients with Open Heart Surgery (개심술환자에 있어 혈청 Troponin-T 농도의 변화에 관한 연구)

  • 박동욱;최석철;김윤규;박종원;조관현
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.125-133
    • /
    • 1998
  • This study was designed to identify the efficiency of serum troponin-T(s-TnT) level as a diagnostic indicator for the perioperative myocardial damage with open heart surgery(OHS) and to compare with the conventional myocardial enzyme tests such as isoenzyme fraction of creatine kinase(% CK-MB) and isoenzyme ratio of lactate dehydrogenase(LDH1/LDH2 ratio). The study was performed on 30 adult patients who underwent OHS from Jan. 1996 to June 1996 at Inje University Pusan Paik Hospital, and they were divided into two groups accor- ding to aortic clamping time(ACT) duration : group I(ACT<60 minutes, n=15); group II (ACT>60 minutes, n=15). S-TnT, % CK-MB, and LDH1/LDH2 ratio were measured in serial blood samples from all subjected patients. The results were obtained as follows. 1. In both groups, s-TnT concentrations increased gradually during OHS and elevated significantly at CPB-10(p<0.001). The peak level was noticed at POD 1 in group I(1.10 $\pm$0.19 ng/ml), whereas, at CPB-off in group II(1.88$\pm$0.42 ng/ml). The elevated levels remained until POD 7 in both groups. 2. %CK-MB was risen significantly with the initiation of operations(p<0.001) and the peak levels were noticed at CPB-off in both groups(7.14$\pm$0.86% in group I, 10.69$\pm$1.27% in group II). Thereafter, these levels returned to normal values at POD 3. 3. There were no significant changes in the values of LDH1/LDH2 ratio during and after OHS compared with the control levels(p>0.05). 4. The serial changes of s-TnT were relatively well correlated with those of changes of % CK-MB(r=0.64, p<0.05). 5. The serial s-TnT levels were significantly higher in group II than group I from B-ACR to POD 1(p<0.05), suggesting that duration of aortic clamping time was a major factor concerned with perioperative myocardial injury. In conclusion, measurement of s-TnT is a very useful indicator in assessing the myocardial cell damage and therefore it is expected that serial checking and evaluation of the s-TnT is very available for identification of the perioperative myocardial damage and for postoperative cares in patients with OHS.

  • PDF

The role of porous graphite plate for high quality SiC crystal growth by PVT method (고품질 4H-SiC 단결정 성장을 위한 다공성 흑연 판의 역할)

  • Lee, Hee-Jun;Lee, Hee-Tae;Shin, Hee-Won;Park, Mi-Seon;Jang, Yeon-Suk;Lee, Won-Jae;Yeo, Im-Gyu;Eun, Tai-Hee;Kim, Jang-Yul;Chun, Myoung-Chul;Lee, Si-Hyun;Kim, Jung-Gon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.2
    • /
    • pp.51-55
    • /
    • 2015
  • The present research is focused on the effect of porous graphite what is influenced on the 4H-SiC crystal growth by PVT method. We expect that it produces more C-rich and a change of temperature gradient for polytype stability of 4H-SiC crystal as adding the porous graphite in the growth cell. The SiC seeds and high purity SiC source materials were placed on opposite side in a sealed graphite crucible which was surrounded by graphite insulator. The growth temperature was around $2100{\sim}2300^{\circ}C$ and the growth pressure was 10~30 Torr of an argon pressure with 5~15 % nitrogen. 2 inch $4^{\circ}$ off-axis 4H-SiC with C-face (000-1) was used as a seed material. The porous graphite plate was inserted on SiC powder source to produce a more C-rich for polytype stability of 4H-SiC crystal and uniform radial temperature gradient. While in case of the conventional crucible, various polytypes such as 6H-, 15R-SiC were observed on SiC wafers, only 4H-SiC polytype was observed on SiC wafers prepared in porous graphite inserted crucible. The defect level such as MP and EP density of SiC crystal grown in the conventional crucible was observed to be higher than that of porous graphite inserted crucible. The better crystal quality of SiC grown using porous graphite plate was also confirmed by rocking curve measurement and Raman spectra analysis.

Anti-Arthritic Effect of Radiation Mutant Perilla frutescens var. crispa and Atractylodes macrophala koidz. (방사선 육종 차조기와 백출 복합추출물의 항관절염 효과)

  • Park, Mi Hee;Kim, Chul Jin;Lee, Jin Young;Keum, Chang Yeop;Kim, In Seon;Jin, Chang Hyun;Ji, Joong-Gu;Kim, Sung-kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.102-113
    • /
    • 2020
  • In this study, anti-arthritic effect of the mixed extract of radiation mutant Perilla frutescens var. crispa and Atractylodes macrophala koidz was investigated. Cell viability was determined by MTT assay in RAW 264.7 cells. The anti-inflammatory effect of mixed extracts was determined through measurement of the levels of reactive oxygen species (ROS) and nitric oxide (NO), release of inflammatory cytokines and expression of NF-κB, COX-2 and iNOS in LPS-induced RAW 264.7 cells after treatment of mixed extracts (5, 10, 25 ㎍/㎖). We showed that the mixed extracts was not toxic in the dose of 5, 10, 25 ug/ml, and significantly inhibited production of nitric oxide and ROS, cytokines including IL-1β, IL-6, TNF-α, and inflammatory proteins including NF-κB, COX-2 and iNOS in LPS-induced RAW 264.7 cells. Moreover, the mixed extract inhibited the type II collagen induced arthritis in DBA mice in the dose of 66.5 and 133mg/kg/day. Therefore, we suggest that mixed extract of radiation mutant Perilla frutescens var. crispa and Atractylodes macrophala koidz can be developed as a raw material for health functional food and therapeutics to treat the inflammatory arthritis.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Homologous and Heterologous Antibody Response of the Patients with Aspergillosis Against Young Mycelia of Aspergilli by Fluorescence Antibody Reaction (형광항체반응을 이용한 Aspergillus 증 환자의 균사표면항원에 대한 항체반응 양상에 관한 연구)

  • Moon, Hi-Joo;Kwon, Hyuk-Han
    • The Korean Journal of Mycology
    • /
    • v.17 no.2
    • /
    • pp.82-90
    • /
    • 1989
  • Detection of antibody against pathogenic fungi in serum specimens of the patients with pulmonary tuberculosis or other lung diseases has been carried out(male) using the indirect fluorescence antibody technique and immunodiffusion tests. Immunodiffusion tests revealed that 104(36.5%) out of 285 patients examined showed a positive precipitin reaction against one or more of fungal antigens. The majority of ID positive patients 64(61.5%) reacted with Aspergillus fumigatus antigen and 49(47.1%) patients reacted with Candida albicans antigen ID positive reaction to A. fumigatus was found little more frequently among male patients, while Candida albicans reactors were found more frequently among female patients. Age distribution of ID positive reactors was high(49.1-43.3%) in age group of 40-59 years, but least or none in age group of less than 30 years. Age of fungal mycelium used as antigen did not effect sensitivity of the indirect flubrescence (IF) technique in detecting antibody to A. fumigatus. Antibody class against A. fumigatus that showed highest titer was IgG and thus FITC labeled anti-IgG immunoglobulin shoul be preferable. As relatively large amount of cell wall components of Aspergilli shared antigenically, a considerable cross-reaction was observed among A. fumigatus, A. flavus and A. niger, but not much with C. albicans. While (IF) has much better sensitivity when compared with ID, relative specificity of the latter procedure cannot to be overried, so that they could be batter used together in order to obtain quantitative measurement of antibody with relative specificity.

  • PDF

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

The Changes of Serum Level of Tumor Necrosis Factor-Alpha, Gamma-Interferon and Soluble-Intercellular Adhesion Molecule-1 Relating to the Progression and Treatment of Patients with Pulmonary Tuberculosis (폐결핵의 진행정도 및 치료에 따른 혈청내 Tumor Necrosis Factor-Alpha, Gamma-Interferon 및 Soluble-Intercellular Adhesion Molecule-1의 변화)

  • Kim, Myung-Hoon;Ahn, Joong-Hyun;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.6
    • /
    • pp.1167-1177
    • /
    • 1998
  • Background : Pulmonary tuberculosis is one of the diseases characterized granuloma formation which was controlled by cellular immune reactions. In the process of granulomatous changes, activated alveolar macrophages and T lymphocytes secrete many cytokines including interleukin-1 (IL-1), tumor necrosis factor-alpha(TNF-$\alpha$), interferon-gamma(IFN-$\gamma$) which mediate inflammatory reactions. Intercelluar adhesion molecule-1(ICAM-1) also known to major role player in inflammatory processes, and increased cellular expressions when endothelial cell was stimulated by IL-1, TNF and IFN. Method : To evaluate relationships among cellular immune reactions and clinical stages, pulmonary tuberculosis patients were classified into three groups according to their clinical stages including minimal, moderate and far advanced tuberculosis. TNF-$\alpha$ IFN-$\gamma$, sICAM-1 (soluble form of ICAM-1) were measured at the time of diagnosis and after 6-months anti-tuberculosis medications by radioimmuno assay or enzyme linked immunosolvent assay. Result : TNF-$\alpha$, IFN-$\gamma$, sICAM-1 were significantly increased in moderate and far advanced pulmonary tuberculosis patients but no meaningful changes in minimal staged patients. 6-months anti-tuberculosis medications reduced serum sICAM-1 levels significantly, related to clinical improvement but no significant changes were found in the serum levels of TNF-$\alpha$ and IFN-$\gamma$. In the point of correlations. positive ones revealed between TNF-$\alpha$ and sICAM-1, also between IFN-$\gamma$ and sICAM-1 but no correlation between TNF-$\alpha$ and IFN-$\gamma$. Conclusion : Measurement of serum sICAM-1 could be useful parameter to evaluate the severity of pulmonary tuberculosis and to monitor disease activities during anti-tuberculosis medications.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Experimental and clinical studies with impedance audiometry; the increase in air volume in the middle ear air system and the pneumatization of human temporal bones (측두골의 함기도와 중이강의 용적이 고막 임피던스에 미치는 영향에 관한 연구)

  • 민양기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.4.4-5
    • /
    • 1977
  • The vibratory energy introduced into the external ear canal is changed by the mechanical factors of eardrum itself, the motility of ossicles, and the air cushion of tympanic cavity and the like. This study was designed to investigate the volume of middle ear cavity and mastoid air cell system as a factor of determining the accoustic impedance of middle ear system. The author studied how the increase in air volume of middle ear cavity effects on the acoustic impedance of middle ear system with dogs' ears and researched the correlation between the degree of pneumatization of temporal bones and the acoustic impedance of middle ear system by comparing the radiological findings of pneumatization (Law's and Towne's projection) with the acoustic impedance measurements with Madsen ZO 70. The result is as follows: 1 The tympanometric findings in control state revealed the curves of type A, and did not change in its configuration by the increase in the air volume of dogs middle ear system. 2. The static compliance of middle ear revealed a distinct and linear increase in proportion to the increase in air volume of middle ear system; the rate of increase was $0.05{\pm}0.02$ cc of static compliance per cc of air volume. 3. Authenticated in the above result and the tendency to increase in static compliance in proportion to the increase in the degree of pneumatization of temporal bones, there was significant regression equation between the degree of pneumatization of temporal bones (x variable) and the static compliance of middle ear system; $y=0.19x{\pm}0.16{\pm}0.05$ It is suggested that the difference in volume of middle ear system plays an important role in the change of the static compliance of middle ear, and the author concludes that the measurement of static compliance of middle ear has clinical value as diagnostic means of evaluating the degree of pneumatization of temporal bones along with some radiological examination.

  • PDF