• Title/Summary/Keyword: Cell measurement

Search Result 1,599, Processing Time 0.023 seconds

Study on Development of the Isolation Resistance Measurement System for Hydrogen Fuel Cell Vehicle (수소연료전지자동차용 절연저항 측정시스템 개발에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Moon, Hyun-Wook;Kim, Hyang-Kon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1068-1072
    • /
    • 2011
  • Hydrogen Fuel Cell Vehicle(HFCV) is system that uses electrical energy of fuel cell stack to main power source, which is different system with other vehicles that use high-voltage, large-current. Isolation performance of this system which is connected with electrical fire and electrical shock is important point. Isolation resistance of electric installation is divided according to working voltage, it follows criterion more than $100{\Omega}$/VDC (or $500{\Omega}$/VAC) about system operation voltage in a hydrogen fuel cell vehicle. Although measurement of isolation resistance in a hydrogen fuel cell vehicle is two methods, it uses mainly measurement by megger. However, the present isolation resistance measurement system that is optimized to use in electrical facilities is unsuitable for isolation performance estimation of a hydrogen fuel cell vehicle because of limit of maximum short current and difference of measurement resolution. Therefore, this research developed the isolation resistance measurement system so that may be suitable in isolation performance estimation of a hydrogen fuel cell vehicle, verified isolation performance about known resistance by performance verification of laboratory level about developed system, and executed performance verification through comparing results of developed system by performance verification of vehicle level with ones of existing megger. Developed system is judged to aid estimation and upgrade of isolation performance in a hydrogen fuel cell vehicle hereafter.

Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones (다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서)

  • Lee Dong Woo;Yi Soyeon;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

A Development of the Recoil Rod Pull Force Measurement System Using the Load Cell with Sleeve (슬리브관을 갖는 로드셀을 이용한 주퇴봉 당김력 계측시스템 개발)

  • Choi, Ju-Ho;Hong, Sung-Soo;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.2
    • /
    • pp.152-159
    • /
    • 2001
  • This paper presents a development of the recoil rod pull force measurement system suing the load cell with a sleeve normally available in the recoil system test. The commercial load cell cannot be used in the test of recoil system floating the breach contact point freely in the air. The load cell is designed and manufactured to meet the recoil system test condition. Theoretical analysis and experimental results show that the accuracy of the developed measurement system is within $\pm$0.5%. We notice that the measurement technique proposed in this paper is accurate and useful in the recoil rod pull force measurement of the recoil system.

  • PDF

Three-Dimensional Fluid Flow Analysis of Photoacoustic Spectroscopy Cell for Measurement of Automotive Exhaust Gas (자동차 배출가스 측정을 위한 Photoacoustic Spectroscopy Cell의 3차원 유동장 해석)

  • 김현철;박종호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.111-118
    • /
    • 2003
  • Recently, environmental damage to urban area becomes serious problem due to the exhaust emissions by increasing the number of vehicle. Especially, exhaust emission from diesel vehicles are blown to be harmful to human health and environment. Photoacoustic Spectroscopy system is very useful technology for simultaneous and continuous measurement of the various components of the automotive exhaust gas. In this study, in order to reduce emission gases from automobile, we tried to develop the measurement system of Photoacoustic Spectroscopy. To improve performance of high sensitive Photoacoustic Spectroscopy system for automotive exhaust emissions, the shape of Photoacoustic Spectroscopy cell was optimized to use the flow analysis. And Exhaust emission data of the 1,500cc gasoline engine was fixed the working fluid. The characteristics of fluid flow for cell were analyzed by various conditions in detail.

Non-invasive Methods for Determination of Cellular Growth in Podophyllum hexandrum Suspension Cultures

  • Chattopadhyay, Saurabh;Bisaria, V.S.;Scheper, T.;Srivastava, A.K.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.6
    • /
    • pp.331-334
    • /
    • 2002
  • Culture conductivity and on-line NADH fluorescence were used to measure cellular growth in plant cell suspension cultures of Podophyllum hexandrum. An inverse correlation between dry cell weight and medium conductivity was observed during shake flask cultivation. A linear relationship between dry cell weight and culture NADH fluorescence was obtained during the exponential phase of batch cultivation In a bioreactor under the pH stat (pH 6) conditions. It was observed that conductivity measurement were suitable for biomass characterisation under highly dynamic uncontrolled shake flask cultivation conditions. However, if the acid/alkali feeding is done for pH control the conductivity measurement could not be applied. On the other hand the NADH fluorescence measurement allowed online-in situ biomass monitoring of rather heterogenous plant cell suspension cultures in bioreactor even under the most desirable pH stat conditions.

Application of Rotating Polarizer Method to Low LC Cell Gap Measurement

  • Kim, Chang-Son;Lee, Gi-Dong;Yoon, Tae-Hoon;Kim, Jae-Chang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.199-200
    • /
    • 2000
  • Measurement of low cell gap and retardation by using a rotating polarizer method was proposed. For more precise calculation and measurement, we applied a retardation film that has large retardation value of $1\;{\mu}m$ to measurement system. From experiments, we proved that cell gap and retardation could be measured even though the values of those are so small.

  • PDF

Development of Fuel Economy Measurement Method for Hydrogen Fuel Cell Vehicles (수소연료전지자동차 연료소비율 측정방법에 대한 연구)

  • Lim, Jong-Soon;Choi, Young-Tae;Yong, Gee-Joong;Kwon, Hae-Boung;Lee, Hyun-Woo;Maeng, Jeong-Yoel
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.636-639
    • /
    • 2009
  • Fuel consumption measurement of Hydrogen fuel cell vehicle is considerably different form internal combustion engine vehicle such as carbon balance method. A practical method of fuel Consumption measurement has been developed for Hydrogen fuel cell vehicles. There are three method of hydrogen fuel consumption testing, gravimetric, PVT(Pressure, Volume and temperature), and Coriolis mass flow, all of which necessitate physical measurements of the fuel supply. The purpose of this research is to measure the fuel consumption of hydrogen fuel cell vehicles on chassis-dynamometer and to give information when the research is intended to develop method to measure hydrogen fuel consumption.

  • PDF

Uncertainty Analysis and Compensation of the Cell for Permittivity Measurement of Solid Materials (고체재료의 유전율 측정용 Cell의 불확도 분석과 보상)

  • Kim, Han-Jun;Yu, Kwang-Min;Kang, Jeon-Hong;Han, Sang-Ok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.53-56
    • /
    • 2008
  • The commercial parallel plate electrodes system with guard-ring electrode have been widely used for measurement of dielectric constants of solid materials. And the specification of the electrodes system is about 1 % of measurement uncertainty. This measurement uncertainty is only estimated the error come from mechanical measurements such as the area of the electrodes and the gap between the electrodes except the error come from the air gap between the electrodes and dielectric specimen. Because it is impossible to measure the air gap. This study analyze the total measurement uncertainties of the commercial dielectric constant test cell using 3 kinds of Standard Reference Materials. As a results, the total measurement uncertainty is much bigger than 1 % and the most of the uncertainty can be reduced by compensation of the error values evaluated in this study.

Reliability Evaluation of Miniaturized Measurement Cell of Effective Thermal Conductivity for Hydrogen Storage Materials (소형 수소저장물질 유효열전도도 측정장치의 신뢰성 평가)

  • LEE, YOUNG HYO;IM, YEON HO
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.5
    • /
    • pp.431-437
    • /
    • 2015
  • Recently, a miniaturized measurement cell of effective thermal conductivity was developed to evaulate the heat transfer characteristics of hydrogen stroage material in the initial step of its development. In this work, the realiablity issues which can occur from this miniaturization of measurement cell were studied in detail by both experiments and numerical simulation of heat transfer. $LaNi_5$ as a reference was used for the reliability evaluation of the miniaturized measurement cell. Numerical simulations of heat transfer for this measurement system were verified through comparison with the experimental data. Under these reliablity studies, we discuss how to overcome the inherent drawbacks of this miniaturized system in order to achieve the high reliability.

Effects of PCB Patterns on EMI Measurement in TEM Cell and Proposal of PCB Design Guidelines (TEM 셀에서 PCB 패턴이 EMI 측정에 미치는 영향 및 PCB 설계 가이드라인 제시)

  • Choi, Minkyoung;Shin, Youngsan;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.272-275
    • /
    • 2017
  • Recently, semiconductor integration density enormously increases and its interconnection width is significantly narrowed, which leads to EMI (electromagnetic interference) problems on chip level. Chip manufacturer exploits TEM cell (transverse electromagnetic cell) to measure EMI on chip level, which requires PCB (printed circuit board) for measurement purpose. However, it is often neglected to consider that PCB patterns and other factors can affect on EMI measurement. In this paper, several test patterns are designed for different PCB design variables, and effects of PCB patterns on EMI measurement in TEM cell are analyzed. Based on these analyses, PCB design guidelines are also proposed to minimize the effects on EMI measurements.