• Title/Summary/Keyword: Cell impedance analysis

Search Result 158, Processing Time 0.028 seconds

A Frequency-dependent Single Cell Impedance Analysis Chip for Applications to Cancer Cell and Normal Cell Discrimination (주파수에 따른 단일세포의 임피던스 분석칩 및 암세포와 정상세포의 구별에의 적용)

  • Chang, YoonHee;Kim, Min-Ji;Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1671-1674
    • /
    • 2014
  • This paper presents a frequency-dependent cell impedance analysis chip for use in cancer and normal cell discrimination. The previous cell impedance analysis chips for flowing cells cannot allow enough time for cell-to-electrode contact to monitor frequency-dependent impedance response. Another type of the previous cell impedance analysis chips for the cells clamped by membranes need complex sample control for making stable cell-to-electrode contact. We present a new impedance analysis chip using the microchamber array, on which a PDMS cover is placed to make stable cell-to-electrode contact for the individual cell trapped in each microchamber; thus achieving frequency-dependent single-cell impedance analysis without complex sample control. Compared to the normal cells, the magnitude of NHBE cells is $60.07{\sim}97.41k{\Omega}$ higher than A549 cells in the frequency range of 95.6 kHz~2MHz and the phase of NHBE is $3.96^{\circ}{\sim}20.8^{\circ}$ higher than A549 cells in the frequency range of 4.37 kHz~2MHz, respectively. It is demonstrated experimentally that the impedance analysis chip performs frequency-dependent cell impedance analysis by making stable cell-to-electrode contact with simple sample control; thereby applicable to the normal cell and cancer cell discrimination.

Computer simulation to determine system parameters of the square-wave adapted fast impedance analyzer for the electrode - electrolyte interface analysis (구형파를 이용한 전극계면 분석용 고속 임피던스 분석기의 설계변수 확정을 위한 컴퓨터 시뮬레이션)

  • Kim Gi-Ryon;Kim Gwang-Nyeon;Shim Yoon-Bo;Jeon Gye-Rok;Jung Dong-Keun
    • Journal of the Korea Society for Simulation
    • /
    • v.14 no.2
    • /
    • pp.45-55
    • /
    • 2005
  • There are electric double layer capacitance, polarization resistance and solution resistance in the interface between electrode and solution. Electrode process could be evaluated by the electrical impedance analysis. The necessities of the electrochemical cell analysis with high speed impedance analyzer are followings: minimization of the effects of electric stimulation on electrochemical cell and the concentration of reactive materials, and optimization of impedance signal resolution. This paper represents the design criteria for the selection and stimulation to develop fast impedance analyzer prototype for a electrochemical cell. It was suggested that the design of 470k sample/s sampling rate, 13 bit ABC resolution, and 140ms recording time is required for high speed impedance analysis system in frequency range between dc and 10kHz.

  • PDF

A study on design of optimal structure of TEM cell for the characteristic impedance matching and analysis of the electric field distribution (특성 임피던스 정합을 위한 TEM CELL의 최적 구조 설계와 전계 분포 해석에 관한 연구)

  • 정성영;이중근
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.99-110
    • /
    • 1996
  • In this paper, the analysis o fthe electric field distribution for TEM cell which is matched iwth 50 is performed, and the relations of variables for characteristic impedance are derived. Quasi-static approximations are used to calculate the fiedl strength of the internal field of TEM cell. The results of the improved method for analysis of the electric field is compared with that of R.J. Spigel. and the improved method for characteristic impedance and the results of numerical analysis are shown.

  • PDF

Performance Analysis of Polymer Electrolyte Membrane Fuel Cell by AC Impedance Measurement (교류 임피던스 측정법을 이용한 고분자 전해질 연료전지의 성능특성 분석)

  • Seo, Sang-Hern;Lee, Chang-Sik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.4
    • /
    • pp.283-290
    • /
    • 2009
  • This study focuses on the performance characteristics of polymer electrolyte membrane fuel cell (PEMFC) using the AC impedance technique. The experiment was carried out to investigate the optimal operating conditions of PEMFC such as cell temperature, flow rate, humidified temperature and back-pressure. The fuel cell performance was analyzed by DC electronic-loader with constant voltage mode and expressed by voltage-current density. Additionally, AC impedance was measured to analysis of ohmic and activation loss and expressed by Nyquist plot. The results showed that the cell performance increased with increase of cell temperature, air flow rate, humidified temperature and backpressure. Also, the activation loss decreased as the increase of cell temperature, air flow rate, humidified temperature and backpressure.

Development of EIS Evaluation Method about PEMFC 1kW STACK (가정용 연료전지 스택의 EIS 평가 기법 개발)

  • Park, Chaneom;Han, Woonki;Jung, Jinsu;Ko, Wonsik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.100.1-100.1
    • /
    • 2011
  • Electrochemical impedance spectroscopy(EIS) are using widely as a useful technique mainly in the field of electrochemical for the analysis of electrode reactions or characteristics of the composites. The response analysis of the systems technique provides comprehensive informations about the characteristic and structure of complex and internal reaction. The EIS is the method to measure impedance of the measurement target classified by the frequency, it select the equivalent impedance model to give same response from the result and it calculate the parameter. Therefore, the chemical reaction inside the fuel cell is to modeling to electrical impedance. And as repeating the same experiment in each of the operating point, we can get each different parameter. As a result, we can establish the equivalent impedance model in each operating point. Therefore, if we use these models, we can evaluate the fuel cell without the internal design parameter of the fuel cell as required in existing modeling. The EIS is used typically technique for distinguish status of fuel cell called SOH(State Of Health). When the fuel cell is degradation, Efficiency and health of the fuel cell is reduced because internal impedance is increase. As usage of these principles, we can evaluate state of fuel cell through the impedance analysis of fuel cells. In this study, we are presents EIS distinction system and algorithm for residential fuel cell systems. At the time of the fuel cell installation in the fields, the EIS system and proposed algorithm will be able to apply as technique for efficiency and performance evaluation about fuel cell system.

  • PDF

Analysis of the Electrical Properties of Solar Cell According to Variation of the Frequency (주파수 변화에 따른 태양전지 전기적 특성 분석)

  • Kim, Seong-Geol;Hong, Chang-Woo;Lee, Kyung-Sup
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.5
    • /
    • pp.372-376
    • /
    • 2012
  • This study focused on the performance characteristics of solar cell using the impedance technique. We measured an impedance according to frequency from 1 Hz until 1 MHz. It could know that the impedance was decreased according to the frequency increases in solar cell. The impedance of single crystal solar cell was 0.61 ${\Omega}$ at 1 Hz, and kept almost settled value to $1{\times}10^2$ Hz. However, the impedance of polycrystal solar cell was $7{\times}10^3{\Omega}$ at 1 Hz.

Performance Analysis of Single Crystal Solar Cell by Impedance Measurement (임피던스 측정법을 이용한 단결정태양전지의 성능 특성 분석)

  • Jung, You-Ra;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.202-202
    • /
    • 2010
  • This study focused on the characteristics of single crystal solar cell using the impedance technique. In this experiment, the impedance was measured according to frequency's from 1mHz until 2MHz. The solar cell is R-L-C series circuit. Capacitance reactance was changed according to changing from low frequency to high frequency. It could know that the impedance was changed according to the frequency increases in solar cell.

  • PDF

A Review of Ac-impedance Models for the Analysis of the Oxygen Reduction Reaction on the Porous Cathode Electrode for Solid Oxide Fuel Cell

  • Kim, Ju-Sik;Pyun, Su-Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.2
    • /
    • pp.106-114
    • /
    • 2005
  • This article covers the theoretical ac-impedance models for the analysis of oxygen reduction on the porous cathode electrode f3r solid oxide fuel cell (SOFC). Firstly, ac-impedance models were explained on the basis of the mechanism of oxygen reduction, which were classified into the rate-determining steps; (i) adsorption of oxygen atom on the electrode surface, (ii) diffusion of adsorbed oxygen atom along the electrode surface towards the three-phase (electrode/electrolyte/gas) boundaries, (iii) surface diffusion of adsorbed oxygen atom m ixed with the adsorption reaction of oxygen atom on the electrode surface and (iv) diffusion of oxygen vacancy through the electrode coupled with the charge transfer reaction at the electrode/gas interface. In each section for ac-impedance model, the representative impedance plots and the interpretation of important parameters attributed to the oxygen reduction reaction were explained. Finally, we discussed in detail the applications of the proposed theoretical ac-impedance models to the real electrode of SOFC system.

The Characteristic Impedance and the Electric Field Uniformity of a GTEM Cell (GTEM cell의 특성 임피던스와 전계 균일도)

  • 이애경;양기곤
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.3
    • /
    • pp.523-532
    • /
    • 1994
  • A knowledge of the accurate characteristic impedance of a GTEM cell is very useful to design it. This paper discusses the characteristic impedance of a GTEM cell applicable to both susceptibility and emission measurements, considering opening angle of it. The over-RGM for analysis is described : this numerical method is operated with respect to the spherical coordinate system. Some results are compared with others and the validity of this analysis is estabished. The characteristic impedances of a GTEM cell with the variation of geometrical constructions on cross section are presented ; the effect of the opening angle on the characteristic impedance is show. Finally, the electirc field uniformities on a cross section of a GTEM cell are considered for various opening angles.

  • PDF

Impedance characteristics of AgO-Zn cell at various State of Charge (AgO-Zn 전지의 충전상태에 따른 임피던스 특성)

  • Yoon, Youn-Saup;Kim, Byung-Kuan;An, Sang-Yong;Kim, Eung-Jin;Lee, Jun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.52-57
    • /
    • 2008
  • In the present study, impedance characteristics for AgO-Zn cell at various State-of-Charge (SoC) has been studied. The impedance measurements of AgO-Zn cell at various SoC were made over the frequency range from 100kHz to 10mHz with an amplitude 5mV. The impedance parameters have been evaluated by the analysis of the data using an equivalent circuit and a Non-linear least squares (NLLS) fitting method. The total resistances reflects the SoC of the cell. This indicates that the total resistance is important parameter for predicting SoC of AgO-Zn cell.