• Title/Summary/Keyword: Ceiling Height

Search Result 98, Processing Time 0.021 seconds

The effect of a slat ceiling on the acoustics of a small performance space (슬랫천장이 소규모실의 음향에 미치는 영향)

  • Oh, Yedam;Lee, Hyojin;Jeong, Daeup
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.363-368
    • /
    • 2018
  • Recently a slat type ceiling is widely used in various spaces, such as music performance spaces and concourse of airport and a general reception area of a building. However, it is hard to find a proper design guideline or material useful in designing such spaces, due to the lack of relevant researches on the effect of a slat ceiling on room acoustics. The present work investigated the effect of a slat type ceiling using a physical scale model method. A 1/20 scale model of a small shoe-box type music performance hall was built and a slat ceiling with different configurations was installed. 6 cases of different ceiling configurations were considered with the combination of 2 slat ceiling height cases and 3 distance cases between slats. The effect of a slat ceiling on the acoustics of a room was evaluated by measuring reverberance($T_{30}$), intelligibility and clarity($D_{50}$ and $C_{80}$), and loudness(G and $G_{80}$).

A Study on the Environmental Design of the classroom in Elementary Schools with Particular Reference to Natural Lighting and Sound Insulation Performance (채광 및 차음성능을 고려한 초등학교 교실의 환경계획적 연구)

  • Son, Chang-Hwan;Choi, Young-Jun;Lee, Kyung-Hoi
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 1997
  • The total evaluation of educational environment is needed with the rapid growth of the number of students. Especially it is very important to evaluate the physical environment of the classroom in elementary schools where the students spend their whole school life. This study aims to evaluate the daylighting and sound insulation performance of the classroom in elementary school, considering factors such as ceiling height and Wi/Wa (Window/Wall) ratio and then to plan the classroom. Analytic results of the daylighting and sound insulation performance show that the optimum Wi/Wa ratio is $35{\sim}45%$. Reduction of the ceiling height from 3.3m has little influence on the distribution of the indoor daylight factor and sound insulation performance

  • PDF

A Correlation Study for the Prediction of the Maximum Heat Release Rate in Closed-Compartments of Various Configurations (다양한 형상의 밀폐된 구획에서 최대 열발생률 예측을 위한 상관식 검토)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.16-23
    • /
    • 2018
  • In a closed-compartment with various configurations, the correlation that can predict the maximum heat release rate (HRR) with the changes in internal volume and fire growth rate was investigated numerically. The volume of the compartment was controlled by varying the length ratio based on the bottom surface shape of the ISO 9705 fire room, where the ceiling height was fixed to 2.4 m. As a main result, the effect of a change in ceiling height on the maximum HRR was examined by a comparison with a previous study that considered the change in ceiling height. In addition, a more generalized correlation equation was proposed that could predict the maximum HRR in closed-compartments regardless of the changes in ceiling height. This correlation had an average error of 7% and a maximum error of 19% for various fire growth rates when compared with the numerical results. Finally, the applicability of the proposed correlation to representative fire compartments applied to the domestic performance-based design (PBD) was examined. These results are expected to provide useful information on predicting the maximum HRR caused by flashover in closed-compartments as well as the input information required in a fire simulation.

Effect of Working Posture on the Productivity and Perceived Discomfort while Drilling on the Ceiling

  • Yoon, Tae-Lim;Yoon, Jangwhon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.549-555
    • /
    • 2013
  • Objective: The purpose of this study was to compare the performance of drilling on the ceiling in three different postures (standing, standing on the ladder and supine on the height adjusted board) and the subjective responses of perceived discomfort after the drilling. Background: Overhead work has been identified as a major occupational risk factor and has been a main research subject. Method: Ten young participants drilled 20 holes at the pre-marked places on the ceiling in three different postures. The drilling duration, resting and drilling heart rate were measured. The levels of perceived discomfort at neck, shoulder, elbow, hand and overall body were asked at the end of each task. Results: The working posture affected the heart rate after the drilling. Perceived discomfort in the neck decreased significantly in supine compared to drilling on the ladder. Conclusion: The results of this study suggest that drilling in supine can be an alternative way to reduce the drilling heart rate and the level of perceived discomfort in the neck without sacrificing the productivity. Application: The results of this study would be considered when drilling on the ceiling is required in construction workers.

Age Estimation by Radiological Measuring Pulp Chamber of Mandibular First Molar in Korean Adults

  • Jeon, Hye-Mi;Kim, Jin-Hwa;Heo, Jun-Young;Ok, Soo-Min;Jeong, Sung-Hee;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.4
    • /
    • pp.146-154
    • /
    • 2015
  • Purpose: The purpose of present study was to develop a method for assessing the chronological age of Korean adults based on the relationship between age and size of pulp cavity using dental radiographs of mandibular first molars. Methods: A total of 325 dental radiographs of Korean adults with known age and gender were selected for the study (199 males and 126 females) which were taken in the period between January 2009 and June 2014 at the Pusan National University Dental Hospital. The measurements were carried out on both orthopantomographs (OPGs) and intraoral periapical radiographs of mandibular first molar and the following ratios were calculated: pulp chamber floor height ratio (F/L), pulp chamber ceiling height ratio (R/L), and pulp chamber depth ratio (D/L). Results: The ratios of measurements on intraoral periapical images of mandible first molar generally produce more reliable data than the measurements on OPGs. The pulp chamber floor height ratio and pulp chamber thickness ratio showed significant correlation with age, whereas the pulp chamber ceiling height ratios showed weak correlation with age. It was found that the best correlations between the ratios and age were found for pulp chamber thickness ratios (r=-0.731 to -0.751). The multiple regression models were derived using 3 ratios that were significantly correlated with age. The determination coefficients ($R^2$) of the models ranged from 0.556 to 0.596. Conclusions: Our results indicate that the pulp chamber thickness and pulp chamber floor height in mandibular first molar are an age-dependent variable in adults which can be used to estimate age with reasonable accuracy. The higher image quality of dental radiographs will probably narrow the age estimation error and improve dental age estimation.

Study on Influence of Air Flow of Ceiling Type Air Conditioner on Fire Detector Response (천장형에어컨 기류가 화재감지기 작동에 미치는 영향 분석)

  • Choi, Moon-Soo;Lee, Keun-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.40-45
    • /
    • 2018
  • This paper is an analysis of the influence of ceiling air conditioner airflow on fire detector response. In order to analyze the response characteristics of fire detector while forming air flow of a ceiling-type air conditioner, fire tests were carried out in accordance with ISO standard. This experiment was carried out in a fire test site of 10 m (width) ${\times}$ 7 m (length) ${\times}$ 4 m (height). As a result of the experiment, the response of fire detector shows a normal pattern that is delayed as the distance from the fire source is increased in the absence of the air conditioner, but it is confirmed that the pattern is not maintained in the strong air flow. When the air flow of air conditioner was strong, the response time was increased by 121% in the smoke detector and by 39% in the heat detector. In the case of ceiling type air conditioners, it is considered that the number of fire detectors should be increased, or a detector with high sensitivity should be installed for early detection of fire.

Morphological Measurements of Anatomic Landmarks in Human Mandibular Molar Pulp Chambers - An in vivo Study

  • Lokade, Joyti;Rawlani, Shivlal;Baheti, Rakhi (Chandak);Roy, Shelly;Chandak, Manoj;Lohe, Vidya
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Exact knowledge of the location and dimension of the pulp chamber help to maintain the pulp healthy during operative procedure and also reduces the risk of perforation of pulp chamber during root canal treatment. This in-vivo study was carried out to measure critical morphology of pulp chamber of mandibular molar using intra-oral periapical radiograph. Materials and Methods: Mandibular molar teeth of 56 patients were evaluated. The mandibular molar teeth whose pulp chamber was not violated by caries, restoration, fracture crown and those having closed apex were included in the study. The intraoral periapical radiographs were taken with paralleling angle technique using radio-opaque grid with 1 mm space. This grid was placed directly on the film. Results: In 94% of the mandibular first molars specimens the pulp chamber ceiling was at the level of the cemento-enamel junction. The measurements showing the lowest percentage variance were buccal cusp to furcation (approximately 11%) and buccal cusp to pulp chamber ceiling (approximately 15%). The distance from the cusp tip to pulp chamber ceiling height was approximately 6.0 mm, the distance from the pulpal floor to the furcation was approximately 3.0 mm, and the average height of a pulp chamber was 1.5 to 2.0 mm. Conclusion: The exact knowledge of distances of pulp chamber from various anatomical landmarks helps in proper assessment of root canals and ultimately avoids the failure of root canal treatment.

Remodeling Project of the 'Yeonsinae' Catholic Church (연신내 성당 리모델링 구축 프로젝트)

  • Bae, Kang-Hee;Lee, Hyok-Jun
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.53-54
    • /
    • 2006
  • Recently with increasing interest in the operation of life cycle, building remodeling business is spreading like a fashion. Keeping pace with the trend, the present project carried out the remodeling of an existing neighborhood facility into a religious facility based on the concepts of remodeling, reform and renovation. Basic requirements were overcoming spatial limitations, solving structural problems, meeting various functional needs, and securing a spatial size, and the project designed the interior of the building according to these requirements suggested by the owner. To overcome the low floor height of the existing space, the main sanctuary on the 1st floor had the ceiling in the form of a slant and installed indirect lighting into the resulting gaps, maximizing the depth and width of the space visually. The subsidiary sanctuary on the first basement was finished with red bricks, forming an arch using the bricks, to create religious atmosphere. However, considering the low floor height as in the 1st floor and the ceiling even lowered by the arch structure, the arch was formed threefold and the radius of the curvature of the arch was enlarged to secure a spacious feeling. The outer appearance was finished with granite on existing structure to save the cost of construction. In addition to the use of the finishing material, the structure of the arch and the frame of the opening part and the finishing of the walls were expressed with uneven surface in order to avoid the plainness of the appearance.

  • PDF

An Experimental Study on Mechanical Behavior of High Strength Concrete Beam with Circular Opening (고강도 철근콘크리트 유공보의 역학적 거동에 관한 실험적 연구)

  • 구범모;박강근;윤승현;김용태
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.609-614
    • /
    • 2000
  • This paper is an experimental study of the normal strength concrete beam and high strength concrete beam for the analysis of bending and shear behavior. In building structure, the story height can be minimized by providing openings in beams which serves for the utility equipments passing through. The dead space in false ceiling increase construction cost, the good ceiling system such as beam with opening give to economical merits because of a substantial reduction in materials and construction cost. For the analysis on the mechanical behavior of the reinforced high strength and normal strength concrete beams with circular opening in the web, the stress concentration of the circular opening, crack pattern and reinforcing methods were studied. Twenty test pieces with different reinforcing methods and difference concrete strength were tested and their resisting forces and load deflection curves were defined in this study.

  • PDF

A Study on the Application of Water Mist Fire Extinguishing System to Machinery Spaces (미분무수 소화설비의 선박용 기관실 적용에 관한 연구)

  • Kim, Ki-Ok;Ann, Byung-Ho;Yang, Woo-Jin;Kim, Young-Han
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.132-133
    • /
    • 2005
  • A study to evaluate the fire extinguishing performance of the water mist system inside simulated machinery spaces according to IMO MSC/Circ.668 was performed. Fire tests were conducted inside a compartment having a area 100$m^2$(10m${\times}$10m) with a ceiling height of 10m and door opening of 2m${\times}$2m in size. Test fuels were used heptane, diesel, wood crib and mineral oil. Water mist nozzles were installed downward at ceiling and horizontally at bilge area. All fires in the test were extinguished within 15minutes of system activation and there was no reignition or fire spread.

  • PDF