• Title/Summary/Keyword: Cavity thickness

Search Result 318, Processing Time 0.035 seconds

Scanning Electron Microscopic Studies on the Features of Compression Wood, Opposite Wood, and Side Wood in Branch of Pitch Pine(Pinus rigida Miller) (리기다소나무 (Pinus rigida Miller) 지재(枝材)의 압축이상재(壓縮異常材), 대응재(對應材) 및 측면재(側面材) 특성(特性)에 관한 주사전자현미경적(走査電子顯微鏡的)인 연구(硏究))

  • Eom, Young-Geun;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.3-18
    • /
    • 1985
  • In Korea, a study on the anatomical features of pitch pine (pinus rigida Miller) branch wood through photo-microscopical method was reported in 1972 by Lee. Therefore, as a further study of Lee's on the anatomical features in branch wood of pinus rigida miller that grows in Korea, compression wood, opposite wood, and side wood were selected and treated for the purpose of comparing their structures revealed on cross and radial surface through scanning electron microscope in this study. The obtained results in this study were summarized as follows; 1. The trachied transition from earlywood to late wood is very gradual and the tracheids are nearly regular in both arrangement and size in compression wood but this transition in opposite wood and side wood is abrupt and the tracheids in opposite wood and side wood are less regular than those in compression wood. Also, the annual ring width of opposite wood is narrower than that of compression wood or side wood and the rays revealed on cross surface of side wood are more distinct than compression wood and opposite wood rays. 2. The tracheids of compression wood show roundish trends especially in earlywood but those of opposite wood and side wood show some angular trends. And intercellular space, helical cavity, and spiral check are present in both earlywood and latewood of compression wood but not present in opposite wood and side wood irrespective of earlywood and latewood. 3. The wall thickness of latewood tracheid is similar to that of earlywood tracheid in compression wood whereas the wall thickness of latewood tracheid is by far thicker than that of earlywood tracheid in opposite wood and side wood and the S3 layer of secondary wall is lack in compression wood tracheid unlike opposite wood and side wood tracheid. 4. The tracheids in compression wood are often distorted at their tips unlike those in opposite wood and side wood and the bordered pit in compression wood tracheid is located at the bottom of helical groove unlike that in opposite wood and side wood tracheid. 5. The bordered pits in radial wall of opposite wood and side wood tracheids are oval in shape but those of compression wood tracheids show some modified oval shape. 6. In earlywood of side wood, the small apertures of cross-field pits are roundish triangle to rectangle and the large one are fenestriform through the coalition of two small ones. However, the small apertures of cross-field pits are upright oval and the large ones are procumbent oval shape in earlywood of opposite wood and the apertures of cross-field pits in compression wood are tilted bifacial convex lens shape in earlywood and slit in late wood because of the border on tracheid side.

  • PDF

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering. Inc., Troy, USA) and ANSYS (Swanson Analysis Systems. Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Viva dent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition. Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

  • PDF

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering, Inc., Troy, USA) and ANSYS (Swanson Analysis Systems, Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Vivadent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition, Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

The Study of Near-field Scanning Microwave Microscope for the Nondestructive Detection System (비파괴 측정을 위한 근접장 마이크로파 현미경 연구)

  • Kim, Joo-Young;Kim, Song-Hui;Yoo, Hyun-Jun;Yang, Jong-Il;Yoo, Hyung-Keun;Yu, Kyong-Son;Kim, Seung-Wan;Lee, Kie-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.508-517
    • /
    • 2004
  • We described a near-field scanning microwave microscope which uses a high-quality dielectric resonator with a tunable screw. The operating frequency is f=4.5 5GHz. The probe tip is mounted in a cylindrical resonant cavity coupled to a dielectric resonator We developed a hybrid tip combining a reduced length of the tapered part with a small apex. In order to understand the function of the probe, we fabricated three different tips using a conventional chemical etching technique and observed three different NSMM images for patterened Cr films on glass substrates. We measured the reflection coefficient of different metal thin film samples with the same thickness of 300m and compared with theoretical impedance respectly. By tuning the tunable screw coming through the top cover, we could improve sensitivity, signal-to-noise ratio, and spatial resolution to better than $1{\mu}m$. To demonstrate the ability of local microwave characterization, the surface resistance of metallic thin films has been mapped.

Millimeter-wave LTCC Front-end Module for Highly Integrated Transceiver (고집적 송수신기를 위한 밀리미터파 LTCC Front-end 모듈)

  • Kim, Bong-Su;Byun, Woo-Jin;Kim, Kwang-Seon;Eun, Ki-Chan;Song, Myung-Sun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.10 s.113
    • /
    • pp.967-975
    • /
    • 2006
  • In this paper, design and implementation of a very compact and cost effective front-end module are presented for IEEE 802.16 FWA(fixed Wireless Access) in the 40 GHz band. A multi-layer LTCC(Low Temperature Co-fred Ceramic) technology with cavity process to achieve excellent electrical performances is used to fabricate the front-end module. The wirebond matching circuit design of switch input/output port and waveguide transition to connect antenna are optimally designed to keep transmission loss low. To reduce the size of the front-end module, the dielectric waveguide filter is developed instead of the metal waveguide filter. The LTCC is composed of 6 layers(with the thickness of a layer of 100 um) having a relative dielectric constant of 7.1. The front-end module is implemented in a volume of $30{\times}7{\times}0.8mm^3$ and shows an overall insertion loss < 5.3 dB, and image rejection value > 49 dB.

EFFECT OF PHOSPHORIC ACID CONCENTRATION ON THE DIFFUSION OF HEMA THROUGH DENTIN (상아질을 통한 HEMA의 확산에 인산농도가 미치는 영향)

  • Yoon, Mi-Ran;Lee, Kwang-Won;Park, Soo-Joung
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.147-155
    • /
    • 1999
  • The purpose of this study was to investigate the effect of phosphoric acid concentration on the movement of 2-hydroxyethylmethacrylate(HEMA) from bonding resin - resin composite combination through dentin in vitro. Freshly extracted human third molar teeth were divided into four groups each of 10 teeth. A closed chamber with 1 ml distilled water was attached to the CEJ of each tooth. An occlusal cavity of 4mm diameter & remaining dentin thickness of 1.0-1.5mm was prepared in each tooth. Dentin was treated with 10% phosphoric acid gel for 15 seconds. 32% phosphoric acid gel for 15 seconds, or with 35% phosphoric acid gel for 15 seconds. A control group not treated with acid gel was also prepared. The cavities were rinsed, dried and then treated with the HEMA-containing All-Bond 2 primer & bonding resin which was light-cured for 10 seconds. The cavities were then restored with Z100 composite resin(shade:A3.5:3M Dent. Prod. USA) & light cured for 30 seconds. Water samples were retrieved from the chambers over a time course (4.32, 14.4, 43.2, 144 & 432 minutes ; 1, 3 & 10 days) and analyzed by high performance liquid chromatography. The results were as follows. 1. HEMA was detected in the pulp chambers of all teeth from 4.32 minutes after resin placement The highest rate of release was in the first sample period (0-4.32 min) & rate of release declined exponentially thereafter. 2. No significant differences were found for mean release rate for HEMA over a time course among the four groups (p>0.05). 3. The diffusion rate was significantly (p<0.05) less for 10% phosphoric acid gel than 32% phosphoric acid gel at the second sample period(4.32-14.4 min). 4. No significant differences were found for cumulative HEMA diffusion among the four groups at 10 days(p>0.05) and mean total(cumulative) release at 10 days for all groups was in the 9 - 16 nmol range. 5. The cumulative release was significantly (p<0.05) less for 10% phosphoric acid gel than 32% phophoric acid gel at the third(14.4-43.2 min) & fourth(43.2-144 min) sample period.

  • PDF

Histological healing after grafting of bilayer artificial dermis in the oral environment (치은부에 이식한 이중인공진피의 조직학적 치유)

  • Kim, Min-Jeong;Chung, Hyun-Ju;Kim, Ok-Su;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.289-299
    • /
    • 2003
  • The autogenous free gingival graft is the most predictable procedure currently used to increase the width of the attached gingiva in periodontics. But the major disadvantage of the procedure is to create the multiple surgical wounds at both a donor site and a recipient site. The other problem is the limited amount of available graft material in oral cavity. Therefore, recent researches have been focused to develop the biomaterial to substitute the autogenous gingival tissue. The purpose of this study was to evaluate the histologic healing after grafting of bilayer artificial dermis, compared to the free gingival graft. Four non-smoking subjects (mean age, 32.5 years) in systemically healthy state and good oral hygiene were selected according to their particular needs for correction of mucogingival problems as suggested by Nabers(1966). The recipient sites were prepared through the procedure for the free gingival graft and were grouped according to the graft materials: Experimental group(n=5) - bilayer artifcia1 dermis ($Terudermis^{(R)}$; Terumo Co. Japan) and Control group(n=6) - free gingival graft with autogenous palatal mucosa. Biopsies were harvested at 1,2,3 and 6 weeks postsurgery to evaluate histologically. At the third week in the experimental group and at the second week of in the control group, the grafts has been clinically stabilized on the recipient bed and the graft border has been blended into the surrounding tissue. In the experimental group after 1 week of grafting, the epithelial migration from the adjacent tissue to graft material was seen and after 3 weeks of grafting, the : nflmmation decreased, collagen layer of the artificial dermis was lost and the basement membrane of epithelium was formed. After 6 weeks of grafting, both groups demonstrated orthokeratinized epithelium and increased thickness of epithelial tissue and the rete peg formation, similar to the adjacent tissue, Histologic evaluation revealed a biologic acceptance and incorporation of the collagen layers of the graft tissue to the host tissue, without foreign body reaction. In conclusion, a bilayer artificial dermis is essentially similar to autogeneous free gingival graft in the correction of mucogingival problems, and has the advantages of decreased patient morbidity (no donor site) and availability of abundant amounts of graft material when needed.

Broadband LTCC Receiver Module for Fixed Communication in 40 GHz Band (40 GHz 대역 고정통신용 광대역 LTCC 수신기 모듈)

  • Kim Bong-Su;Kim Kwang-Seon;Eun Ki-Chan;Byun Woo-Jin;Song Myung-Sun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1050-1058
    • /
    • 2005
  • This paper presents how to design and implement a very compact, cost effective and broad band receiver module for IEEE 802.16 FWA(Fixed Wireless Access) in the 40 GHz band. The presented receiver module is fabricated in a multi-layer LTCC(Low Temperature Cofired Ceramic) technology with cavity process to achieve excellent electrical performances. The receiver consists of two MMICs, low noise amplifier and sub-harmonic mixer, an embedded image rejection filter and an IF amplifier. CB-CPW, stripline, several bond wires and various transitions to connect each element are optimally designed to keep transmission loss low and module compact in size. The LTCC is composed of 6 layers of Dupont DP-943 with relative permittivity of 7.1. The thickness of each layer is 100 um. The implemented module is $20{\times}7.5{\times}1.5\;mm^3$ in size and shows an overall noise figure of 4.8 dB, an overall down conversion gain of 19.83 dB, input P1 dB of -22.8 dBm and image rejection value of 36.6 dBc. Furthermore, experimental results demonstrate that the receiver module is suitable for detection of Digital TV signal transmitted after up-conversion of $560\~590\;MHz$ band to 40 GHz.

Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing (평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this work, EPM (effective point of measurement) of parallel plate ionization chamber with three different spacing were investigated. If the plate separation is less than 2 mm one generally assumes that the effective point of measurement is just behind the front window of the parallel plate ionization chamber. For chamber with relatively large separation, such as the ones used for very accurate exposure measurements, this assumption breaks down and the EPM depends on plate separation and thickness of the front window. For parallel plate chambers, conventional theoretical analyses suggest that the EPM is the inner front wall and that it shifts towards the geometric centre of the chamber as the plate separation increases. The PP-IC (parallel plate ionization chamber) is fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far are 0.9, 1.9, and 3.1 cc. The gap between two electrodes ranges from 3, 6, and 10mm. Also the charge-to-voltage converter is designed to collect the electrons produced in the ionization chamber cavity. As the result of our experiment, the EPM shift was within 0.6 mm in photon beams and 0.4 mm to 2.5 mm in electron beams for the plate separation of 6 mm and 10 mm. EPM shifts towards the geometric center of the chamber as the plate separation increases.

  • PDF

Augmentation of Pyriform Margin Using Porous High-Density Polyethylene Sheet In Unilateral Cleft Lip Nasal Deformity (일측성 구순열비변형에서 다공성 폴리에틸렌 판을 이용한 상악골이상구증대술)

  • Han, Ki Hwan;Kim, Jin Han;Choi, Tae Hyun;Kim, Jun Hyung;Son, Dae Gu
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.431-438
    • /
    • 2008
  • Purpose: The common deformity after the correction of unilateral cleft lip nasal deformity is nasal asymmetry, and it is caused by the hypoplasia of the pyriform aperture. To correct this, many procedures have been applied, but still many problems are present. Authors performed the inlay and onlay insertion of porous high density polyethylene sheet(1 mm thickness $Medpor{(R)}$ sheet) in the hypoplastic pyriform margin of cleft side and obtained satisfactory results. Methods: 11 cases were performed and the mean follow up period was 15.1 months. Their mean age was 23.6 years. Under general anesthesia, bilateral pyriform margin was exposed. $Medpor{(R)}$ sheets in "match stick" like shaped were inlay inserted, and kidney shaped were onlay inserted fixating with two 6 mm titanium screws. After the surgery, the results was evaluated by photogrammetric analysis. On the basal view, the distance from the subalare and labiale superius' to the transverse baseline connecting the both cheilions was measured from the cleft side and the non-cleft side. Then, the postoperative symmetry was assessed by obtaining the cleft side against the non-cleft side as proportion index, defined as lateral and medial upper lip contour index. Results: There were 2 infections. The cause was because the inserted implant was too long and thus protruded to the base of nasal cavity. The lateral upper lip contour index was from 95.49 to 103.27, and medial upper lip contour index was from 90.92 to 100.49, it was statistically increased, and thus the symmetry was improved. However clinically mild depression remained at nostril floor. Conclusion: Authors performed porous high density polyethylene sheet inlay and onlay insertion for the hypoplasia of the pyriform margin in unilateral cleft lip nasal deformity. It was found that depressed pyriform margin and upper lip were corrected effectively except for the nostril floor, for which an additional soft tissue augmentation would be necessary. The inlay insertion has risk of protrusion, thus the guideline of the use of artificial prosthesis should be observed strictly.