• Title/Summary/Keyword: Cavity liner

Search Result 24, Processing Time 0.027 seconds

Experimental study on the mechanical response and failure behavior of double-arch tunnels with cavities behind the liner

  • Zhang, Xu;Zhang, Chengping;Min, Bo;Xu, Youjun
    • Geomechanics and Engineering
    • /
    • v.20 no.5
    • /
    • pp.399-410
    • /
    • 2020
  • Cavities often develop behind the vault during the construction of double-arch tunnels, generally in the form of various defects. The study evaluates the impact of cavities behind the vault on the mechanical and failure behaviors of double-arch tunnels. Cavities of the same sizes are introduced at the vault and the shoulder close to the central wall of double-arch tunnels. Physical model tests are performed to investigate the liner stress variation, the earth pressure distribution and the process of progressive failure. Results reveal that the presence of cavities behind the liner causes the re-distribution of the earth pressure and induces stress concentration near the boundaries of cavities, which results in the bending moments in the liner inside the cavity to reverse sign from compression to tension. The liner near the invert becomes the weak region and stress concentration points are created in the outer fiber of the liner at the bottom of the sidewall and central wall. It is suggested that grouting into the foundation soils and backfilling injection should be carried out to ensure the tunnel safety. Changes in the location of cavities significantly impact the failure pattern of the liner close to the vault, e.g., cracks appear in the outer fiber of the liner inside the cavity when a cavity is located at the shoulder close to the central wall, which is different from the case that the cavity locates at the vault, whereas changes in the location of cavities have a little influence on the liner at the bottom of the double-arch tunnels.

A STUDY ON THE EFFECT OF AMALGAM CAVITY LINER APPLICATION ON THE MARGINAL LEAKAGE AND RETENTION OF AMALGAM RESTORATIONS (Amalgambond Liner의 도포가 amalgam 수복재의 변연누출과 유지력에 미치는 영향에 관한 연구)

  • Kim, Tae-Sung;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.800-817
    • /
    • 1996
  • In this study, we tried to evaluate the effect of Amalgambond liner application on the degree of marginal leakage and retention of amalgam restoration by comparing with that of the Copalite and All-bond 2. The results obtained from this experiment were as follows; 1. Tensile strength representing the bond between amalgam and tooth structure was the highest in Amalgambond, and All-Bond 2, Copalite in descending order. There were statistically significant difference between each group(P<0.05). 2. The degree of microleakage in Amalgambond was lower than that of All-Bond 2, and Copalite, but no stastically significant difference could be found (P>0.05). 3. The liner such as Amalgambond or All-Bond 2 were evaluated to be superior to the conventional Copalite in bond strength as well as in microleakage. But the result of this study could not show the superiority of one material over the others; Amalgambond and All-bond 2. Besides the results of the study, other factors, such as practical convenience, should be considered in determining the selection of material. The support of welldesigned clinical studies on this subject are in demand.

  • PDF

A study on development of the high-flowable filling material and application in the old tunnel (터널 배면공동 뒤채움재 개발과 노후터널의 적용에 관한 연구)

  • Ma, Sang-Joon;Seo, Kyoung-Won;Bae, Gyu-Jin;An, Sang-Chul;Im, Kyung-Ha
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.3
    • /
    • pp.195-205
    • /
    • 2002
  • Most tunnel damage such as cracks or leakage which exist in tunnel liner commonly, is caused by the cavities that exist behind the tunnel liner, through the tunnel safety inspections. These cavities were analysed to check if they affect the stability of tunnels. This study is on the development of the controlled low-strength and flowable filling material which an be applied to the cavity behind the tunnel lining. The backfilling material studied here is crushed sand and stone-dust which is in cake-state and is a by-product obtained in the producing process of aggregate. Varying the compound mixing ratio, laboratory tests of compression test and chemical analyses were carried out. In addition, the material was applied to an old tunnel for the performance assessment.

  • PDF

COMPARISON OF MICROLEAKAGE OF GALLIUM ALLOY AND AMALGAM RESTORATION (갈륨과 아말감 수복물의 변연미세누출에 관한 비교 연구)

  • Lee, Min-Ho;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.269-277
    • /
    • 1998
  • This in vitro study compared the microleakage of 4 lining conditions when used with Gallium alloy GF II and Valiant PhD. Class V cavity was prepared on both buccal and lingual surface of 80 extracted human premolar & molar teeth with one margin in enamel and another in dentin. Before restoration, prepared cavities were applied to no-liner, cavity varnish, Scotchbond multipurpose, and Superbond D-liner II plus according to manufacture's instructions. The restored teeth were stored in saline for 1 week, then thermocycled for 100 times, stained with 0.5% basic fuchsin dye for 1 day, sectioned, and observed using a light microscope. Following results were obtained. 1. The leakage value of Superbond-lined group showed significantly lower than that of nolined group on both margins of Valiant PhD(p<0.05). 2; There was no significant difference between the 4 lining conditions in Gallium alloy GF II (p>0.05). 3. When We make a comparison between Gallium alloy GF II and Valiant PhD under same lining conditions, the microleakage value of Gallium alloy GF II showed lower than that of Valiant PhD on occlusal & gingival margin(p<0.05) except for Superbond-lined group(p>0.05).

  • PDF

Double-Diffusive Convection Due to Heating from Below in a Rotating Cylindrical Cavity (회전하는 원통형밀폐용기내의 아랫면가열에 의한 이중확산대류에 관한 실험적 연구)

  • 강신형;이태홍;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1731-1740
    • /
    • 1995
  • Experimental investigations have been made to study the double-diffusive nature of convection of an initially stratified salt-water solution due to heating from below in a rotating cylindrical cavity. The objective is to examine the flow phenomena and the heat transfer characteristics according to the changes in temperature gradient, concentration gradient and rotating velocity of cavity. Thermal and solutal boundary conditions at side wall are adiabatic and impermeable, respectively. The top and bottom plate are maintained each at constant temperature and concentration. The cavity is put into a state of solid body rotation. Like the stationary case, the types of initially-formed flow pattern are classified into three regimes depending on the effective Rayleigh number and Taylor number; stagnant flow regime, single mixed-layer flow regime and successively formed multi-mixed layer flow regime. At the same effective Rayleigh number, the number of initially-formed mixed layer and its growth rate decrease as the effect of rotation increases. The temperature and concentration profiles are both uniform in each layer due to convective mixing in the layered-flow regime, but look both liner in stagnant flow regime and single mixed-layer flow regime. At the interface between adjacent layers, the temperature changes smoothly but the concentration changes rapidly.

A STUDY ON THE CLINICAL USAGE OF THE FLOWABLE COMPOSITE RESIN (유동성 복합레진의 임상적 용도에 관한 검토 연구)

  • Park, So-Young;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.255-261
    • /
    • 2002
  • The purpose of this study was to compare the microleakage pattern of flowable composite resin to sealant, composite resin used in preventive resin restoration and glass ionomer cement used as liner. 120 extracted sound human molars were divided into 6 groups : group 1 and 2:sealant ; group 3 and 4:preventive resin restoration ; group 5 and 6:sandwich technique restoration. For the experimental groups(group 2, 4 and 6), flowable composite resin(Tetric flow) was used. For the control group, Concise was used as sealant material(group 1), Z-100 with Concise were used as preventive resin restoration(group 3), and Vitrebond was used as cavity liner(group 5). All the restorations were thermocycled and the degree of dye penetration was evaluated with stereomicroscope. The microleakage of each group was measured and statistically analyzed. The results of the present study were as follows : 1. In group 1 and 2, there was no statistically significant difference in microleakage between Concise and Tetric flow(p>0.05). 2. In groups of preventive resin restorations, there was no statistically significant difference in microleakage between Z-100 with Concise and Tetric flow(p>0.05). 3. The microleakage of Vitrebond and Tetric flow used as liner showed no statistically significant difference(p>0.05).

  • PDF

MICROLEAKAGE EVALUATION IN AMALGAM RESTORATIONS USED WITH BONDING AGENTS (수종의 접착제를 사용한 아말감 수복시의 미세 변연 누출에 관한 연구)

  • Choi, Sang-Cheol;Park, Joon-Il;Kwom, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.447-463
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of copal varnish and five bonding agents(Scotchbond Multi-Purpose Plus Dental Adhesive System, Panavia 21, All Bond 2, Superbond D-Liner II plus, Fuji Duet) in reducing microleakage under amalgam restorations. Class V cavity were prepared on both buccal and lingual surface of sixty extracted human molars with cementum margin and were filled with different kinds of liners and amalgam. All teeth were stored at $37^{\circ}C$ in physiologic saline solution. After 1 week they were thermally stressed for 500 cycles between 5 and $55^{\circ}C$ in baths containing 0.5 % basic fuchsin dye. The dye penetrations were observed with a stereomicroscope. Scanning electron micrographs were taken of representative tooth sections from each group to assess the nature of the tooth/liner/amalgam interface. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The results were as follows ; 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. At the dentin and enamel margins, the leakage value of Copalite-lined group showed significantly higher than that of no liner group (p<0.05), but showed significantly lower than that of bonding agent lined-groups (p<0.05). 3. There was no significant difference between the bonding agent lined-groups (p>0.05). 4. On the backscattered scanning electron microscopy observation, discontinuous gaps were observed between amalgam and dentin in the bonding agent-lined amalgam restorations and the bonding agents appeared to fill the gap space and were mixed with amalgam particles. At the amalgam/tooth interface, unsealed dentin and continuous gaps were found in both unlined and Copalite-lined restorations.

  • PDF

Design and Fabrication of a Dual Linear Polarization Sinuous Antenna with Improved Cross Polarization Isolation (교차편파 격리도를 개선한 이중선형 편파 시뉴어스 안테나의 설계 및 제작)

  • Kim, Jee-heung;Ryu, Hong-kyun;Chae, Myung-ho;Kim, Jung-hoon;Park, Beom-jun;Park, Young-ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.123-132
    • /
    • 2018
  • In this paper, we design and fabricate a dual liner polarization sinuous antenna with improved cross polarization isolation (XPI). The proposed antenna is composed of four arm radiators for generating dual linear polarization and excited by wideband microstrip balun with Klopfenstein taper structure. Also, two-step cylindrical cavity structure is applied to reduce back radiation. Honeycomb-typed absorbing material is inserted into the cavity to reduce performance degradation by reflected wave. To enhance cross polarization isolation in low frequency band, resistors are adapted between outer arm and the rim of cavity. We confirmed that the fabricated antenna can be applied for polarization measurement due to improved XPI in the low band.

Effect of lining application techniques on microleakage in class II composite restorations (다양한 방식으로 적용한 이장재가 2급와동 복합레진 수복의 미세누출에 미치는 영향)

  • Hwang, Byung-Moon;Kim, Joo-Hyung;Park, Ji-Man;Millstein, Philip;Park, Eun-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the microleakage in class II cavity resin restorations used with resin-modified glass ionomer (RMGI) lining material depending on two different applying methods; classical delivery method using a dental explorer and a specially designed rotating bur. Materials and Methods: A total thirty-six extracted teeth were prepared with a class II proximal box, and randomly divided into three groups: 1) control group with no lining added and the proximal box restored (Group I), 2) the second group used RMGI as a lining material which was spread with an explorer (Group II), 3) the third group used a specially designed rotating bur to thin out RMGI (Group III). All teeth were restored with the same manner using incrementally placed resin composite. All 36 teeth were prepared and sectioned for the dye penetration test, and observed with a stereomicroscope for scoring the dye penetration. Results: When RMGI liners were used, both groups using an explorer and the special bur with the liner had significantly less microleakage than the control group with no liner (P < 0.05). The 50% of the group with RMGI liner using the bur showed no microleakage under a dye penetration test whereas all the teeth in control group showed microleakage of different degrees. However, there was no statistically significant difference between Group II and Group III. Conclusion: RMGI is an effective lining material to decrease microleakage in class II composite resin restorations regardless of applying methods.

Elastic Wave Propagation in Nuclear Power Plant Containment Building Walls Considering Liner Plate and Concrete Cavity (라이너 플레이트 및 콘크리트 공동을 고려한 원전 격납건물 벽체의 탄성파 전파 해석)

  • Kim, Eunyoung;Kim, Boyoung;Kang, Jun Won;Lee, Hongpyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.3
    • /
    • pp.167-174
    • /
    • 2021
  • Recent investigation into the integrity of nuclear containment buildings has highlighted the importance of developing an elaborate diagnostic method to evaluate the distribution and size of cavities inside concrete walls. As part of developing such a method, this paper presents a finite element approach to modeling elastic waves propagating in the containment building walls of a nuclear power plant. We introduce a perfectly matched layer (PML) wave-absorbing boundary to limit the large-scale nuclear containment wall to the region of interest. The formulation results in a semi-discrete form with symmetric damping and stiffness matrices. The transient elastic wave equations for a mixed unsplit-field PML were solved for displacement and stresses in the time domain. Numerical results show that the sensitivity of displacement, velocity, acceleration, and stresses is large depending on the size and location of the cavity. The dynamic response of the wall slightly differs depending on the existence of the containment liner plate. The results of this study can be applied to a full-waveform inversion approach for characterizing cavities inside a containment wall.