• Title/Summary/Keyword: Cavity height

Search Result 169, Processing Time 0.028 seconds

Numerical Simulation for Prediction of Existing Cavity Location on Explosion-Induced Building Collapse (폭발에 의한 건축물 붕괴 시 매몰공동 위치 예측에 관한 수치해석 사례 연구)

  • Jung, Jahe;Park, Hoon;Kim, Kwang Yeom;Shin, Hyu-Soung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.94-101
    • /
    • 2015
  • When a severe disaster such as a building collapse occurs, a first priority for rapid rescue is to find a location where people are highly expected to be buried but alive. It is, however, very difficult to correctly designate the location of such cavities by conventional geophysical survey due to a pile of debris of building members. In this study, location of possible lifeguard cavities were evaluated through a series of simulations of building collapse by explosion depending on the height of the building, a structure of basement floor and a location of explosion. Three types of building structure: five-story, ten-story and fifteen-story were prepared as a model for the simulation. As a results, in the case of low building, only basement floor partially collapsed. On the other hand, in the case of high building, a collapsed range on the inside of the building increased and lifeguard spaces were formed only in the lateral side or corner of the building. In addition, when a wall exists in the basement floor, the possibility that cavities could be formed increased compared to the cases without wall. However, for the fifteen-story building case, no possible lifeguard cavity was found. It is noted that for a high rise building, the height of building more affect forming of safeguard cavity than the structure of the basement floor.

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.

A Study on the Characteristics of an Air Cavity Attached Under a Flat Plate (평판에 형성된 공기공동 특성에 관한 연구)

  • Kim, Jong-Hyun;Oh, Jae-Young;Seo, Dae-Won;Lee, Seung-Hee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.5
    • /
    • pp.396-403
    • /
    • 2011
  • The concept of an air lubrication has long been an object of attention since it can be utilized to reduce the frictional resistance, and what is more, it is eco-friendly. The present study examines the basic characteristics of an air cavity with intention of applying the air lubrication technology to the reduction of the resistance of a ship without excessive power increment. For the purpose, an air cavity was created at the bottom of a flat plate by injecting air behind a backward step and the hydrodynamic properties of the air cavity and the surrounding flow has been investigated experimentally and numerically. The influence of the step height and the air flow rate have been more carefully studied since they are presumed to be the main parameters affecting the characteristics of an air cavity. The results indicates that the shapes of the air cavities attached on the flat plate become "U" or "V" type depending on the incoming flow velocity and air flow rate. The study also confirms that the length of the air cavity increases with increase in air flow rate but there is a certain critical limit in the flow rate above which increase in the air cavity length is no more evident.

Influence of Electrode Position on Performance of Sparkjet Actuator Using Numerical Analysis (수치해석을 이용한 전극 위치에 따른 스파크제트 액츄에이터의 성능 연구)

  • Shin, Jin Young;Kim, Hyung-Jin;Kim, Kyu Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.11
    • /
    • pp.753-760
    • /
    • 2019
  • Sparkjet actuator, also known as plasma synthetic jet actuator, which is a kind of active flow control actuator is considered as being high possibility for the supersonic flow control due to ejecting stronger jet compared to the other active flow control actuators. Sparkjet actuator generates high temperature and high pressure flow inside the cavity by using arc plasma and leads momentum by ejecting such flow through orifice or nozzle. In this research, numerical calculation of sparkjet actuator with respect to the location of electrodes which exists inside the cavity is conducted and the change of the performance of sparkjet actuator is suggested. As the location of electrodes goes closer to the bottom of the cavity, impulse is increased and the average pressure inside the cavity maintains higher. When the location of electrode is 25% and 75% of the entire cavity height, impulse is 2.515 μN·s and 2.057 μN·s, respectively. Each impulse is changed by about 9.92% and -10.09% compared to when the location of electrodes is 50% of the entire cavity height.

A Study on Consolidation Characteristics at Sand Pile Adjacent Ground by Cavity Expansion Theory (공동확장이론에 의한 Sand Pile 주변지반에서의 압밀특성에 관한 연구)

  • 천병식;여유현
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.231-238
    • /
    • 2000
  • Sand piling method is one of the most widely used methods to improve soft soils. There are several methods to install sand piles, but driven pile method is considered as one of the easiest method. This method simply pushes down the sand piles into soft soils, so that the excess pore pressure would be generated if the soil is saturated. This pore pressure acts as consolidation load. If the amount of sand pile induced pore pressure can be predicted in reasonable ways, the effects of sand piling to improve soft soils would be predicted, and the height of preload can be reduced. In this article, sand pile induced excess pressure was predicted by cavity expansion theory, and the predicted values were compared with the field measured values. The results showed fair agreements between the measured and the predicted excess pore pressure.

  • PDF

Traumatic Diaphragmatic Hernia: A Report of Two Cases (외상성 횡경막 Hernia: 2례 보고)

  • 김영태
    • Journal of Chest Surgery
    • /
    • v.6 no.2
    • /
    • pp.237-242
    • /
    • 1973
  • Two cases of traumatic diaphragmatic hernia are reported, who were operated on in this department during the last 12 months` period. The first case, a 34 year old male, fell from 6 meters` height while he was working on electric pole. He sustained rib fractures, left 8th, 9th and 10th rib, left diaphragmatic rupture and ileal perforation. In the pleural cavity, there were stomach, omentum, left lobe of liver, transverse colon and ileum, which were reduced into the peritoneal cavity, and the diaphragmatic aperture was closed through anterolateral thoracotomy. After closure of the thoracic incision, median abdominal incision was made and closed the ileal perforation by primary suture. The second case was a 19 year old tyre repairman, who felt abrupt severe abdominal pain during lifting a heavy lyre. A barium study revealed a marked displacement of the stomach into the left pleural cavity. Immediately, thoracotomy was performed and closed the ruptured diaphragm after reduction of the herniated stomach, omentum, transverse colon, spleen and small intestine. The size of the diaphragmatic aperture were measured 17cm. in first case and 12cm. in the other respectively. Both cases discharged after uneventful recovery.

  • PDF

A Study on Critical Reynolds Numbers of Two-Dimensional Closed Cavity by CFD (CFD에 의한 2차원 밀폐캐비티의 임계레이놀즈수에 관한 연구)

  • 김진구;조대환;이영호
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.122-129
    • /
    • 1997
  • Flow characteristics of two-dimensional closed square cavities near unsteady critical Reynolds numbers were studied numerically at five Reynolds numbers : 8${\times}10^3$, 8.5${\times}10^3$, 9${\times}10^3$, 9.5${\times}10^3$ and $10^4$ were investigated. A convection conservative difference scheme based upon SOLA to maintain the nearly 2nd-order spatial accuracy was adopted on irregular grid formation. Irregular grid number is 80${\times}$80 and its minimum size is about 1/400 of the cavity height(H) and its maximum is about 1/53 H. The result shows that the critical Reynolds number indicating the emergence of flow unsteadiness exists near Re=8.5${\times}10^3$ and their flow patterns reveal periodic fluctuation during transient and fully-developed stages.

  • PDF

A Case Study on The Reduction and Examination for Noise and Vibration of Backpass Heat Surface in the Power Plant Boiler (발전용 보일러의 후부 전열면 소음진동 저감에 관한 사례 연구)

  • Lee, Gyoung-Soon;Lee, Tae-Hoon;Moon, Seung-Jae;Lee, Jae-Heon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.642-647
    • /
    • 2008
  • The boiler structure is determined by combustion characteristics and construction costs in the combustion chamber of a large commercial boiler. The heat transfer in boiler is composed of the radiation and the convection. The convective heat transfer has happened to back-pass heating surface. The combustion gas sequentially passes through the reheater tube, 1st economizer tube, and 2nd economizer tube. In case of being lowered in boiler height, we have to install additional tube bundle in back-pass heating surface for increasing the heat transfer of boiler, which causes the noise and vibration from combustion gas. When the combustion gas passes through the back-pass tube bundle in specified load of commercial boiler, this paper analyzes the acoustic characteristics between vortex-shedding frequency and natural frequency in tube bundle cavity. The case study reduce the resonance by changing natural frequency characteristics of tube-bundle cavity using a way to install ant-noise baffle in the direction of combustion gas flow.

  • PDF

Flow Characteristics of Two-Dimensional Closed Cavity near Unsteady Critical Reynolds Numbers (2차원의 밀폐캐비티의 비정상 임계레이놀즈수 근방의 유동특성)

  • Kim, Jin-Gu;Kim, Chun-Sik;Lee, Yeong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.5
    • /
    • pp.22-29
    • /
    • 1996
  • Flow characteristics of two-dimensional closed square cavities near unsteady critical Reynolds numbers were studied numerically at four Reynolds numbers : $8{\times}10^3,\;8.5{\times}10^3,\;9{\times}10^3\;and\;9.5{\times}10^3.$ A convection conservative difference scheme based upon SOLA to maintain the nearly 2nd-order spatial accuracy is adopted on irregular grid formation. Irregular grid number is $80{\times}80$ and its minimum size is about 1/400 of the cavity height(H) and its maximum is about 1/53 H. The result shows that the critical Reynolds number indicating the emergence of flow wnsteadiness is ranging from Re=$8{\times}10^3\;to\;8.5{\times}10^3$ and their flow patterns reveal periodic fluctuation during transient and fully developed stages. But macroscopic flow behavior in terms of instantaneous and time-mean characteristics represent remarkable difference.

  • PDF

Development of Automatic Runner-Valve Actuator for The Filling Balance of Multi Cavity (복수 캐비리 충전 균형 조절을 위한 자동 런너 밸브 조절기 개발)

  • Lee, Y.J.;Lee, E.J.;Park, H.P.;Cha, B.S.;Rhee, B.O.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.370-373
    • /
    • 2009
  • The runner-valve is an effective solution for the filling balance of the multi cavity molds. Automation of the runner-valve system is necessary for more efficient and accurate control of the filing balance. We designed an automatic runner-valve actuator for the automation and characterized the actuator by experiment. We obtained a linear relationship between motor-driving time and the height of the runner-valve. However, the motor-driving times for upward and downward directions were different due to the frictional characteristics of the actuators. Also we obtained the motor-driving times for backlashes of the 4 actuators. The results were used to formulate the relationship between the resin-arrival time and the flow rate change of the runner-valve with the theoretical equation that was derived in the previous research.

  • PDF