• 제목/요약/키워드: Cavity detection

검색결과 184건 처리시간 0.03초

수박에서의 초음파 전파 특성에 관한 실험적 연구 (An Experimental Study on the Propagation Characteristics of Ultrasonic Wave in Watermelon)

  • 장경영;김만수;조한근
    • Journal of Biosystems Engineering
    • /
    • 제23권6호
    • /
    • pp.615-620
    • /
    • 1998
  • The nondestructive internal quality evaluation of agricultural products has been strongly required from the needs for individual inspection. In recent, ultrasonic wave has been considered as a solution for this problem. It transmit well through most materials and can handle safely and easily. However, specially in a watermelon, it is known that general frequency band (higher than 20kHz) ultrasonic waves do not transmitted well due to severe attenuation. The objectives of this study were to find out the proper waveform and frequency of the ultrasonic waves that transmit well inside the watermelon, and to analyze the transmitted waveform in order to make clear the structure of wave propagation in watermelon. The result of several experiments showed that 2kHz shear wave was the most suitable for the detection of internal cavity in the watermelon. Also, it was found that the surface wave did not influence the directly transmitted bulk wave. These results could be a basis of application of ultrasonic wave on the evaluation of internal quality of the watermelon.

  • PDF

비유전율을 이용한 공기감지장치에 관한 연구 (A study on the air detector using relative dielectric constant)

  • 이혁수;김청월
    • 센서학회지
    • /
    • 제16권5호
    • /
    • pp.384-388
    • /
    • 2007
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed a detection circuit of sensing scheme. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the tygon tube of the mock system.

블레이드 형상변화에 따른 수중 추진기 방사 소음 예측에 관한 연구 (Numerical Prediction of Underwater Propeller Noise)

  • 설한신
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.344-347
    • /
    • 2006
  • Noise reduction and control is an important problem in the performance of underwater acoustic system and on the habitability of the passenger ship for crew and passenger. Furthermore, sound generated by a propeller is critical in underwater detection and is often related to the survivability of the vessel especially for military purpose. Generally propeller noise is often the dominant noise source of marine vehicle. The flow field is analyzed with potential-based panel method, and then the time dependent pressure and sheet cavity volume data are used as the input for Ffowcs Williams-Hawkings formulation to predict the far-field acoustics. Through this study, the dominant noise source of underwater propeller is analyzed, which will provide a basis for proper noise control strategies.

  • PDF

온도변화에 따른 냉장고 발포시스템용 에어믹싱가스 농도검출기술에 관한 연구 (A Study on Concentration Detection Technology of Air Mixing Gas according to Temperature Variation for Refrigerator Foam System)

  • 구영목;양준석;조상영;김민성;노춘수
    • 한국산업융합학회 논문집
    • /
    • 제19권2호
    • /
    • pp.95-100
    • /
    • 2016
  • This study proposes the temperature compensation algorithm using thermopile detector for non-dispersive infrared Nitrogen gas sensor. From the output voltage of thermistor that is attached onto the infrared detector, the ambient temperature was extracted. The effects of temperatures on the properties of sensor module characteristics of narrow bandpass filter, optical cavity and infrared lamp, and air mixing gas have been introduced in order to implement the temperature compensation algorithm.

Development of a Wideband EPR Spectrometer with Microstrip and Loop Antennas

  • Ponomaryov, A.N.;Choi, K.Y.;Suh, B.J.;Jang, Z.H.
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.178-182
    • /
    • 2013
  • We have developed a new non-conventional electron paramagnetic resonance (EPR) spectrometer, in which no resonant cavity was used. We previously demonstrated a wide frequency range operation of an EPR spectrometer using two loop antennas, one for a microwave transmission and the other for signal detection [1]. In contrast to Ref. [1], the utilization of a microstrip antenna as a transmitter enhanced a capability of wide-band operation. The replacement of conventional capacitors with varactor diodes makes resonance condition easily reproducible without any mechanical action during tuning and matching procedure since the capacitance of the diodes is controlled electronically. The operation of the new EPR spectrometer was tested by measuring a signal of 1,1-diphenil-2-picrylhydrazyl (DPPH) sample in the frequency range of 0.8-2.5 GHz.

Low Temperature Test of HWR Cryomodule

  • Kim, Heetae;Kim, Youngkwon;Lee, Min Ki;Park, Gunn-Tae;Kim, Wookang
    • Applied Science and Convergence Technology
    • /
    • 제25권3호
    • /
    • pp.47-50
    • /
    • 2016
  • Low temperature test for half-wave resonator (HWR) cryomodule is performed at the superfluid helium temperature of 2 K. The effective temperature is defined for non-uniform temperature distribution. Helium leak detection techniques are introduced for cryogenic system. Experimental set up is shown to make the low temperature test for the HWR cryomodule. The cooldown procedure of the HWR cryomodule is shown from room temperature to 2 K. The cryomodules is precooled with liquid nitrogen and then liquid helium is supplied to the helium reservoirs and cavities. The pressure of cavity and chamber are monitored as a function of time. The vacuum pressure of the cryomodule is not increased at 2 K, which shows leak-tight in the superfluid helium environment. Static heat load is also measured for the cryomodule at 2.5 K.

Diagnosis of Acute Leukemia from Oral Manifestation

  • Kang, Min-Hye;On, Dohyun;Kim, Jin Woo;Ryu, Jaeyoung
    • Journal of Korean Dental Science
    • /
    • 제11권2호
    • /
    • pp.82-85
    • /
    • 2018
  • Leukemia is a hematological malignant disease with various clinical symptoms. Due to the fatal nature of the disease, early detection is important. Oral manifestations include ulcers and gingival enlargement with bleeding. Moreover, myeloid sarcoma or opportunistic infections may also occur. This report introduces a 31-year-old male presenting with generalized gingival enlargement with bleeding and another 81-year-old female with neoplasm on the left retromolar area. Both were diagnosed as acute monocytic leukemia. These cases implicate that gingival enlargement or mucosal lesion in the oral cavity may represent underlying systemic diseases. Related to this, it has to be reminded that making timely diagnosis and referral according to the clinical findings is crucial.

ELISA를 이용한 돼지 톡소플라스마병의 조기 진단에 관한 연구 (Use of the enzyme-linked immunosorbent assay for the detection of toxoplasmosis in swine)

  • 서명득;장동화;주후돈
    • 대한수의학회지
    • /
    • 제29권4호
    • /
    • pp.567-575
    • /
    • 1989
  • This study was conducted to evaluate the possibility of application of a microenzyme-linked immunosorbent assay(micro-ELISA) for the serodiagnosis of specific toxoplasma antibodies in swine sera and this test was performed as a microplate system by coating the polystyrene plates with toxoplasma soluble antigen, incubated serially diluted sera, then added horse radish peroxidase labelled goat anti-swine IgG(r) conjugate followed by o-phenylenediamine as substrate. The color development by enzyme-substrate reaction was determined by the photometric reading [ELISA reader at 490nm (OD)] and visual reading. The soluble antigen was prepared from the tachyzoites in mouse peritoneal cavity. A total of 1,200 swine sera from pig slaughter-house and a total of 116 swine sera from pig breeding station (S-C farm) were tested for the detection of antibodies to Toxoplasma gondii. The results obtained were summarized as follows: 1. The optimal reactions of indirect ELISA for the test sera were determined by the dilution of antigen 1:256 and 1:3,200 of horse radish peroxidase conjugate [anti-swine IgG(r)]. 2. The specific togoplasma antibody(IgG) in pigs infected with Tp artificially were detected as the serum titers of 1:64 or 1:128 at one week postinfection. 3. Of a total of 1,200 swine sera from pig slaughter-house 505 samples of sera were detected as positive (42.1%) and of a total of 116 swine sera from S-C pig breeding station 68 samples of sera as positive (58.6%). 4. The specific antibody(IgG) detection rates against a total of 1,200 test sera from pig slaughter-house were not significant between male (43.1%) and female (40.7%). 5. The indirect ELISA was proved to be a sensitive and specific procedure for the serodiagnosis of swine toxoplasmosis and also evaluated as an effective screening test for the large scale of test samples in laboratory.

  • PDF

초음파 및 레이더를 활용한 콘크리트 내부결함탐상 알고리즘 개발 (The Development of an Algorithm for Internal Defect Inspection of Concrete using Ultrasonic Detective Device and Radar Equipment)

  • 오홍섭;주민관;이주원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1029-1032
    • /
    • 2008
  • 최근 각 분야에서 연구 및 개발하고 있는 IT 및 자동화 경향이 건설 유지관리에도 전파됨에 따라 유지관리 로봇의 개발과 함께 개발될 비파괴 시스템의 장착이 각광 받을 것으로 예상되고 있다. 토목 구조물의 경우, 이러한 첨단기술의 발전과 더불어 유지관리 측면에서 이러한 첨단기술을 사용하는 것이 적극적으로 고려되고 있다. 그 중 NDT 비파괴 검사방법이 토목구조물의 효율적인 유지관리를 해 적합한 방법으로 사료되고 있다. 본 연구에서는 콘크리트 구조물의 내부결함 탐상을 위해서 초음파 및 레이더 장비가 적용되었으며, 이를 활용하여 실험실 및 현장실험을 통하여 그 적용성을 실험적으로 분석하였다. 실험결과, 초음파 및 레이더 장비는 콘크리트 구조물의 내부결함을 탐상하는데 효과적임으로 분석되었다. 또한 본 연구에서는 실험결과를 바탕으로, 초음파 및 레이더 장비를 적용한 콘크리트 구조물의 유지관리를 위한 알고리즘을 개발 및 제안하였다.

  • PDF

Detection of different foreign bodies in the maxillofacial region with spiral computed tomography and cone-beam computed tomography: An in vitro study

  • Abolvardi, Masoud;Akhlaghian, Marzieh;Shishvan, Hadi Hamidi;Dastan, Farivar
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.291-298
    • /
    • 2020
  • Purpose: The detection and exact localization of penetrating foreign bodies are crucial for the appropriate management of patients with dentoalveolar trauma. This study compared the efficacy of cone-beam computed tomography (CBCT) and spiral computed tomography (CT) scans for the detection of different foreign bodies composed of 5 frequently encountered materials in 2 sizes. The effect of the location of the foreign bodies on their visibility was also analyzed. Materials and Methods: In this in vitro study, metal, tooth, stone, glass, and plastic particles measuring 1×1×1 mm and 2×2×2 mm were prepared. They were implanted in a sheep's head in the tongue muscle, nasal cavity, and at the interface of the mandibular cortex and soft tissue. CBCT and spiral CT scans were taken and the visibility of foreign bodies was scored by 4 skilled maxillofacial radiologists who were blinded to the location and number of foreign bodies. Results: CT and CBCT were equally accurate in visualizing metal, stone, and tooth particles of both sizes. However, CBCT was better for detecting glass particles in the periosteum. Although both imaging modalities visualized plastic particles poorly, CT was slightly better for detecting plastic particles, especially the smaller ones. Conclusion: Considering the lower patient radiation dose and cost, CBCT can be used with almost equal accuracy as CT for detecting foreign bodies of different compositions and sizes in multiple maxillofacial regions. However, CT performed better for detecting plastic particles.