• Title/Summary/Keyword: Cavity

Search Result 6,416, Processing Time 0.042 seconds

Verify Image-Guided Shifts for 6DoF Couch using Yonsei Cancer Center QA Set (Yonsei Cancer Center QA Set을 이용한 6DoF Couch의 이동 정확성 검증)

  • Jung, Dongmin;Park, Hyokuk;Yoon, Jongwon;Lee, Sangkyu;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.7-18
    • /
    • 2017
  • Purpose: A QA Set was established to verify the movement accuracy of image-guided 6DoF Couch and to evaluate its usefulness. Materials and Methods: Two sets of linear accelerators equipped with 6DoF Couch and CBCT were used. Using the established QA Set, each CBCT image was obtained over 15 times through the Penta-Guide Phantom installed with off-set shift values along six translational (Translation; TX, TY, TZ) and rotational (Rotation, Pitch; RX, Roll; RY, Yaw; RZ) directions. Using this method, we compared the reference image and the registration image, and we analyzed the error calculated by measuring the positional accuracy of the modified 6DoF Couch. Results: The Air Cavity corresponding to the Pixel of the reference image and the registration image were all contained between 30 and 66, and the revealing high registration accuracy. Error between the modified off-set value of 6DoF Couch and the measured value along translational directions were $0.25{\pm}0.18mm$ in the TX direction, $0.25{\pm}0.25mm$ in the TY direction, and $0.36{\pm}0.2mm$ in the TZ direction. Misalignments along the rotational axis were $0.18{\pm}0.08^{\circ}$ in the RX direction, $0.26{\pm}0.09^{\circ}$ in the RY direction, and $0.11{\pm}0.08^{\circ}$ in the RZ direction, it was corrected precisely for any value. Conclusion: Using the YCC QA Set, we were able to verify the error of 6DoF Couch along both the translational and rotational directions in a very simple method. This system would be useful in performing Daily IGRT QA of 6DoF Couch.

  • PDF

A SURVEY ON THE USE OF COMPOSITE RESIN IN CLASS II RESTORATION IN KOREA (2급 와동 수복 시 한국 치과 지사들의 복합레진 사용 실태 연구)

  • Shin, Dong-Ho;Park, Se-Eun;Yang, In-Seok;Chang, Ju-Hea;Lee, In-Bog;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • The purpose of this study was to assess the current materials, methods and difficulties according to the year of licence and educational background of Korean dentists in Class II direct composite resin restorations. Total 17 questions were included in the questionnaire. Questions were broadly divided into two parts: first. operator's information. and second. the materials and methods used in Class II posterior composite restoration. The questionnaire was sent to dentists enrolled in Korean Dental Association via e-mail. Total 12,193 e-mails were distributed to dentists. 2,612 e-mails were opened, and 840 mails (32.2%) were received from respondents. The data was statically analyzed by chi-square test using SPSS(v. 12.0.1, SPSS Inc. Chicago, IL, USA). Male dentists among respondents was 79%. 60.3% of the respondents acquired their licences recently (1998-2007), and 77% practiced in private offices. 83.4% have acquired their knowledge through school lectures, conferences and seminars. For the Class II restorations, gold inlays were preferred by 65.7% of respondents, while direct composite resin restorations were used by 12.1 % amalgam users were only 4.4% of respondents. For the restorative technique, 74.4% of respondents didn't use rubber dam as needed. For the matrix. mylar strip (53.4%), metal matrix (33.8%) and Palodent system (6.5%) were used. 99.6% of respondents restored the Class II cavity by incremental layering. Obtaining of the tight interproximal contact was considered as the most difficult procedure (57.2%) followed by field isolation (21 %). Among various bonding systems, 22.6% of respondents preferred SE Bond and 20.2% used Single Bond. Z-250 was used most frequently among a variety of composite resins.

Management of Patients with Traumatic Rupture of the Diaphragm

  • Hwang, Sang-Won;Kim, Han-Yong;Byun, Jung-Hun
    • Journal of Chest Surgery
    • /
    • v.44 no.5
    • /
    • pp.348-354
    • /
    • 2011
  • Background: Traumatic rupture of the diaphragm is an unusual type of trauma. In addition, it is difficult to diagnose because it can be accompanied by injuries to other organs. If it is not detected early, the mortality rate can increase due to serious complications. Diaphragmatic rupture is an important indicator of the severity of the trauma. The aim of this study was to investigate the factors affecting the incidence of complications and mortality in patients who had surgery to treat traumatic rupture of the diaphragm. Materials and Methods: The subjects were patients who had undergone a diaphragmatic rupture by blunt trauma or stab wounds except patients who were transferred to other hospitals within 3 days of hospitalization, from January 2000 to December 2007. This study was a retrospective study. 43 patients were hospitalized, and 40 patients were included during the study period. Among them, 28 were male, 12 were female, and the average age was 42 (from 18 to 80). Outcome predictive factors including hypoxia, ventilator application days, revised trauma score (RTS), injury severity score (ISS), age, herniated organs, complications, and the mortality rate were investigated. Results: Causes of trauma included motor vehicle crashes for 20 patients (50%), falls for 10 (25%), stab wounds for 8 (20%), and agricultural machinery accidents for 2 (5%). Most of the patients (36 patients; 90%) had wound sites on the left. Diagnosis was performed within 12 hours for most patients. The diaphragmatic rupture was diagnosed preoperatively in 27 patients (70%) and in 12 patients (30%) during other surgeries. For surgical treatment, thoracotomy was performed in 14 patients (35%), laparotomy in 11 (27.5%), and a surgery combining thoracotomy and laparotomy in 15 patients (37.5%). Herniated organs in the thoracic cavity included the stomach for 23 patients (57.5%), the omentum for 15 patients (37.5%), the colon for 10 patients (25%), and the spleen for 6 patients (15%). Accompanying surgeries included splenectomy for 13 patients (32.5%), lung suture for 6 patients (15%), and liver suture for 5 patients (12.5%). The average hospital stay was $47.80{\pm}56.72$ days, and the period of ventilation was $3.90{\pm}5.8$ days. The average ISS was $35.90{\pm}16.81$ (11~75), and the average RTS was $6.46{\pm}1.88$ (1.02~7.84). The mortality rate was 17.5% (7 patients). Factors affecting complications were stomach hernia and age. Factors affecting the mortality rate were ISS and RTS. Conclusion: There are no typical symptoms of the traumatic rupture of the diaphragm by blunt trauma. Nor are there any special methods of diagnosis; in fact, it is difficult to diagnose because it accompanies injuries to other organs. Stab wounds are also not easy to diagnose, though they are relatively easy to diagnose compared to blunt trauma because the accompanying injuries are more limited. Suture of the diaphragm can be performed through the chest, the abdomen, or the thoracoabdomen. These surgical methods are chosen based on accompanying organ injuries. When there are many organ injuries, there are a great number of complications. Significant factors affecting the complication rate were stomach hernia and age. ISS and RTS were significant as factors affecting the mortality rate. In the case of severe trauma such as pelvic fractures, frequent physical examinations and chest X-rays are necessary to confirm traumatic rupture of the diaphragm because it does not have specific symptoms, and there are no clear diagnosis methods. Complications and the mortality rate should be reduced with early diagnosis and with treatment by confirming diaphragmatic rupture in the thoracic cavity and the abdomen during surgery.

Dose Alterations at the Distal Surface by Tissue Inhomogeneity in High Energy Photon Beam (조직 불균질성에 의한 고에너지 광자선의 선량변화)

  • Kim, Young-Ai;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.277-283
    • /
    • 1995
  • Purpose : This study was performed to measure dose alteration at the air-tissue interface resulting from rebuild-up to the loss of charged particle equilibrium in the tissues around the air-tissue interfaces. Materials and Methods : The 6 and 10-MV photon beam in dual energy linear accelerator were used to measure the surface dose at the air-tissue interface The polystyrene phantom sized $25{\times}25{\times}5\;cm^3$ and a water phantom sized $29{\times}29{\times}48\;cm^3$ which incorporates a parallel-plate ionization chamber in the distal side of air gap were used in this study. The treatment field sizes were $5{\times}5\;cm^2,\;10{\times}10\;cm^2\;and\;20{\times}20\;cm^2$. Air cavity thickness was variable from 10 mm to 50 mm. The observed-expected ratio (OER) was defined as the ratio of dose measured at the distal junction that is air-tissue interface to the dose measured at the same point in a homogeneous phantom. Results : In this experiment, the result of OER was close or slightly over than 1.0 for the large field size but much less (about 0.565) than 1.0 for the small field size in both photon energy. The factors to affect the dose distribution at the air-tissue interface were the field size, the thickness of air cavity. and the photon energy. Conclusion : Thus, the radiation oncologist should take into account dose reduction at the air-tissue interface when planning the head and neck cancer especially pharynx and laryngeal lesions, because the dose can be less nearly $29{\%}$ than predicted value.

  • PDF

Protective effect of Codium fragile extract on fine dust (PM2.5)-induced toxicity in nasal cavity, lung, and brain cells (미세먼지(PM2.5)로 유도된 세포(비강, 폐, 뇌)독성에 대한 청각(Codium fragile)의 보호효과)

  • Kim, Gil Han;Park, Seon Kyeong;Kang, Jin Yong;Kim, Jong Min;Shin, Eun Jin;Moon, Jong Hyeon;Kim, Min Ji;Lee, Hyo Lim;Jeong, Hye Rin;Heo, Ho Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.223-229
    • /
    • 2021
  • To evaluate the protective effect of Codium fragile on fine dust (PM2.5)-induced cytotoxicity, we investigated its antioxidant activity and cell protective effect on PM2.5-exposed cells. The 40% ethanolic extract of C. fragile showed the highest total phenolic content, whereas the water extract of C. fragile showed the highest total polysaccharide content. The protective effect of the extracts on PM2.5-induced oxidative damage in nasal cavity (RPMI2650), lung (A549), brain (MC-IXC), hippocampus (HT-22), and microglia (BV-2) cells was evaluated by measuring the intracellular reactive oxygen species (ROS) content and cell viability. The results showed that the 40% ethanolic extract more efficiently inhibited ROS production than the water extract. In contrast, PM2.5-exposed cells treated with the water extract showed higher viability than those treated with the 40% ethanolic extract.

Development of 3D Viewer for Tree Cavity using Pulse Ultrasound (펄스 초음파를 이용한 수목 공동부 3D 구현 프로그램 제작)

  • Son, Jungmin;Kang, Sunghoon;Moon, Jongwook;Yoon, Seokkyu;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.265-271
    • /
    • 2021
  • The pattern of the tree's internal swelling depends on many causes. Since it is difficult to detect these various causes of swelling with a general method, if the state of swelling for a long time cannot be confirmed, serious damage to the trees may occur due to enlargement of the swelling area. In the method of acquiring a tree tomography image, an impulse passing through the tree is generated by tapping the sensor with a rubber mallet, and the moving speed is recorded. In this paper, to measure cracks, cavities, and swelling due to physical damage, we developed a 3D viewer that can know the internal state of a tree using a tree cross-section image acquired from Arbotom to determine the degree of swelling inside the tree. Based on this, we tried to present data that can be referred to when surgical operation of trees is required. In order to acquire a tomographic image of a tree, 6 sensors were attached to the three Yangpala and Maple trees, and a 1 m-long tree was measured using the Arbotom program, and a 3D image was implemented through the 3D Viewer created using MATLAB. In addition to simply acquiring images, the cross-sectional length and volume of the tree were measured. In the actually produced 3D Viewer, the length of the part where the swelling of the maple tree occurred was 33.12 cm, and the swelling of the yangpala tree was measured as 21.41 cm. The volume of the maple tree was measured to be 78.832 ㎤. As a result of comparing the cross-sectional image of the Arbotom and the 3D image, the same result as the real aspect of the tree was obtained, so it can be judged that the reliability of the manufactured software is also secured, and data to be applied to the surgical tree operation through the created Viewer is provided. It is believed that the damage will be minimized.

Electrochemical Performance of CB/SiOx/C Anode Materials by SiOx Contents for Lithium Ion Battery (SiOx 함량에 따른 CB/SiOx/C 음극재의 전기화학적 특성)

  • Kim, Kyung Soo;Kang, Seok Chang;Lee, Jong Dae;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.117-123
    • /
    • 2021
  • In this study, the composite was prepared by mixing SiOx, soft carbon, and carbon black and the electrochemical properties of lithium ion battery were investigated. The content of SiOx added to improve the capacity of the soft carbon anode material was varied to 0, 6, 8, 10, 20 wt%, and carbon black was added as a structural stabilizer for reducing the volume expansion of SiOx. The physical properties of prepared CB/SiOx/C composite were investigated through XRD, SEM, EDS and powder resistance analysis. In addition, the electrochemical properties of prepared composite were observed through the charge/discharge capacity, rate and impedance analysis of the lithium ion battery. The prepared CB/SiOx/C composite had an inner cavity capable of mitigating the volume expansion of SiOx by adding carbon black. The formed internal cavity showed a low initial efficiency when the SiOx content was less than 8 wt%, and low cycle stability when the content of SiOx was less than 20 wt%. The CB/SiOx/C composite containing 10 wt% of SiOx showed an initial discharge capacity of 537 mAh/g, a capacity retention rate of 88%, and a rate of 79 at 2C/0.1C. SiOx was added to improve the capacity of the soft carbon anode material, and carbon black was added as a structural stabilizer to buffer the volume change of SiOx. In order to use the CB/SiOx/C composite as a high-efficiency anode material, the mechanism of the optimal SiOx and the use of carbon black as a structural stabilizer was discussed.

Crystallographic Study on the Selectivity and Distribution of Sr2+ Ions Within Zeolite A In the Presence of Competing Na+ Ions in Aqueous Exchange Solution (Na+ 경쟁이온이 존재하는 수용액에서 Zeolite A 내 Sr2+ 이온의 선택성 및 분포에 관한 결정학적 연구)

  • kim, Hu Sik;Park, Jong Sam;Lim, Woo Taik
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.1
    • /
    • pp.41-50
    • /
    • 2022
  • To study the properties of Sr2+ exchange into zeolite A with increasing the molar concentration of Na+ in given exchange solution, four single crystals of fully dehydrated Sr2+- and Na+- exchanged zeolite A were prepared by the bath method using mixed ion-exchange solutions. The Sr(NO3)2:NaNO3 molar rations of the ion exchange solution were 1:1(crystal 1), 1:100(crystal 2), 1:250(crystal 3), and 1:500 (crystal 4), respectively, with a total concentration of 0.05 M. The single-crystals were then vacuum dehydration at 623 K and 1×10-4 Pa for 2 days. Their single-crystal structures were determined by single-crystal synchrotron X-ray diffraction techniques in the cubic space group Pm3-m, at 100(1) K, and were then refined to the final error indices of R1/wR2=0.047/0.146, 0.048/0.142, 0.036/0.128, and 0.040/0.156 for crystals 1, 2, 3, and 4, respectively. In crystals 1 and 2, the 6 Sr2+ ions are found at three different crystallographic sites. In crystal 3, 1 Sr2+ and 10 Na+ ions are found in large cavity and sodalite unit. In crystal 4, only 12 Na+ ions occupy three equipoints. The degree of Sr2+ ion-exchange decreased sharply from 100 to 16.7 to 0% as the initial Na+ concentration increase and the Sr2+ concentration decrease. In addition, the unit cell constant of the zeolite framework decreased with this lower level of Sr2+ exchange.

A Study on Pullout-Resistance Increase in Soil Nailing due to Pressurized Grouting (가압 그라우팅 쏘일네일링의 인발저항력 증가 원인에 관한 연구)

  • Jeong, Kyeong-Han;Park, Sung-Won;Choi, Hang-Seok;Lee, Chung-Won;Lee, In-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.101-114
    • /
    • 2008
  • Pressurized grouting is a common technique in geotechnical engineering applications to increase the stiffness and strength of the ground mass and to fill boreholes or void space in a tunnel lining and so on. Recently, the pressurized grouting has been applied to a soil-nailing system which is widely used to improve slope stability. Because interaction between pressurized grouting paste and adjacent ground mass is complicated and difficult to analyze, the soil-nailing design has been empirically performed in most geotechnical applications. The purpose of this study is to analyze the ground behavior induced by pressurized grouting paste with the aid of laboratory model tests. The laboratory tests are carried out for four kinds of granitic residual soils. When injecting pressure is applied to grout, the pressure measured in the adjacent ground initially increases for a while, which behaves in the way of the membrane model. With the lapse of time, the pressure in the adjacent ground decreases down to a value of residual stress because a portion of water in the grouting paste seeps into the adjacent ground. The seepage can be indicated by the fact that the ratio of water/cement in the grouting paste has decreased from a initial value of 50% to around 30% during the test. The reduction of the W/C ratio should cause to harden the grouting paste and increase the stiffness of it, which restricts the rebound of out-moved ground into the original position, and thus increase the in-situ stress by approximately 20% of the injecting pressures. The measured radial deformation of the ground under pressure is in good agreement with the expansion of a cylindrical cavity estimated by the cavity expansion theory. In-situ test revealed that the pullout resistance of a soil nailing with pressurized grouting is about 36% larger than that with regular grouting, caused by grout radius increase, residual stress effect, and/or roughness increase.

Tumorigenesis after Injection of Lung Cancer Cell Line (SW-900 G IV) into the Pleural Cavity of Nude Mice (누드마우스의 흉강에 폐암세포주의 주입에 의한 종양형성과 HER2/neu와 TGF-${\beta}_1$의 발현)

  • Park, Eok-Sung;Kim, Song-Myung;Kim, Jong-In
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.588-595
    • /
    • 2010
  • Background: Base on types of tumor, the types of expressed tumor is diverse and the difference in its expression rate is even more various. Due to such reasons an animal model is absolutely needed for a clinical research of lung cancer. The author attempted oncogenesis by cultivating a cell line of non-small cell carcinoma and then injecting it inside thoracic cavities of nude mice. The author conducted quantitative analyses of HER2/neu tumor gene - an epidermal growth factor receptor (EGFR) related to lung cancer, and TGF-${\beta}_1$, which acts as a resistance to cell growth inhibition and malignant degeneration. In order to investigate achievability of the oncogenesis, histological changes and the expression of cancer gene in case of orthotopic lung cancer is necessary. Material and Method: Among 20 immunity-free male BALB/c, five nude mice were selected as the control group and rest as the experimental group. Their weights ranged from 20 to 25 gm (Orient, Japan). After injection of lung cancer line (SW900 G IV) into the pleural cavity of nude mice, They were raised at aseptic room for 8 weeks. HER2/neu was quantitatively analyzed by separating serum from gathered blood via chemiluminiscent immunoassay (CLIA), and immunosandwitch method was applied to quantitatively analyze TGF-${\beta}_1$. SPSS statistical program (SPSS Version 10.0, USA) was implemented for statistical analysis. Student T test was done, and cases in which p-value is less than 0.05 were considered significant. Result: Even after lung cancer was formed in the normal control group or after intentionally injected lung cancer cell line, no amplification of HER2/neu gene showed reaction. However, the exact quantity of TGF-${\beta}_1$ was $28,490{\pm}8,549pg/mL$, and the quantity in the group injected with lung cancer cell was $42,362{\pm}14,449pg/mL$, meaning 1.48 times highly Significant (p<0.483). It proved that HER2/neu gene TGF-${\beta}_1$ had no meaningful interconnection. Conclusion: TGF-${\beta}_1$ gene expressed approximately 1.48 times amplification in comparison to the control group. The amplification of TGF-${\beta}_1$ meant somatic recuperation inhibition mechanism due to carcinogenesis in nude mice was definitely working. It may be implemented as a quantitative analysis that allows early detection of lung cancer in human body.