• Title/Summary/Keyword: Cause of failure

Search Result 2,137, Processing Time 0.03 seconds

The Effects of a Company's Response Type Strategy due to New Product Failure on Consumers' Negative WOMs : The Moderating Roles of both Cause-related Marketing Activity and Message Strategy (신제품 실패에 따른 기업의 대응유형전략이 소비자의 부정적 구전에 미치는 영향: 공익연계 마케팅 활동여부와 메시지전략의 조절역할)

  • Yun, Hui Kyung;Choi, Young Min;Bae, Sang Wook
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.2
    • /
    • pp.93-107
    • /
    • 2018
  • The Purpose of This Study is to Investigate Consumers' Negative WOMs due to the Crisis Response Strategy that Companies Perform in Crisis Situations due to the Failure of New Products. To do This, the Crisis Scenarios and Response Strategies were Manipulated Using a Virtual Laptop Company, and then an Experiment was Performed. The Results of This Experimental Design are as Follows. First, According to The Response Type Strategies, It is Found that Apologizing rather than Denying for the Crisis Response Mitigates the Negative WOMs more. Second, It is Found that the Companies that have Engaged in Cause-Related Marketing Activities before the Crisis Caused by New Product Failure Mitigate Consumers' Negative WOMs more than those which have not. Third, It is Shown that the Message Strategy of the Firm does not Affect Consumers' Negative WOMs. Fourth, the Interaction between the Response Type Strategy and the Cause-Related Marketing Activities are Found to Exist, but the Interaction Between The Response Type Strategy and the Message Strategy does not Appear.

Acute Respiratory Failure during Splanchnic Nerve Block in COPD Patient (만성폐색성 폐질환 환자에서의 내장신경차단중 발생한 급성호흡부전)

  • Chang, Won-Young;Choe, Kun-Chun
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.200-204
    • /
    • 1991
  • Neurolytic splanchnic nerve block is a relatively safe and effective method for the relief of intractable pain caused by upper abdominal cancer. We have experienced a case of severe acute respiratory failure during splanchnic nerve block under control of X-ray fluoroscopy. We think that the most likely cause of the acute respiratory failure was an asthmatic attack due to anxiety and dyspnea from the injury or stimulation of the diaphragm and pleura in this case.

  • PDF

Acute liver failure in children (소아 급성 간부전의 임상적 의의)

  • Kim, Kyung Mo
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.9
    • /
    • pp.841-847
    • /
    • 2007
  • Acute liver failure (ALF) is a very rare but devastating illness in children. Specific treatment to recovery is often not available, and the underlying cause of the liver failure is often unknown and diverse especially in children. Liver transplantation has increased the chance of survival; however it needs an optimal timing to reach the best result which is not familiar to pediatrician. This article discusses the current knowledge of the epidemiology, backgrounds and factors to be considered before establishing the treatment of ALF in children.

Open Heart Surgery in Patients with Chronic Renal Failure (만성 신부전 환자의 심장수술 - 개심술 4례 보고 -)

  • 김정택
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.482-487
    • /
    • 1990
  • The leading cause of death in patients with chronic renal failure is cardiovascular diseases. The problems relevant to cardiac surgery in these patients are occurring more frequently with a growing number of patients at risk. Among these, important risk factors related to uremic patients undergone open heart surgery are fluid and electrolytes imbalance, coagulopathy, increased susceptibility to infection. Since 1968 when Lansing and colleagues reported the first successful aortic valve replacement in patients with chronic renal failure and infective endocarditis, there have been increasing reports of the cardiopulmonary bypass surgery in chronic renal failure patients with acceptable perioperative morbidity and mortality From Jan. 1988 to Nov. 1989 we have experienced four uremic patients necessitating open heart surgery ; one needing a coronary artery bypass graft and the other 3 needed cardiac valve replacement. Based on our observations we would like to suggest followings 1]Intraoperative ultrahemofiltration during C-P bypass thought to be an excellent means for the control of hyperkalemia and fluid balance. 2] The immediate postoperative application of peritoneal dialysis instead of hemodialysis is beneficial in controlling fluid and electrolyte imbalance. 3]The cause of one early postoperative death was not associated to renal failure, rather it was the result of an accidental rupture in the right ventricular wall.

  • PDF

RCM Based Failure-Prediction System for Equipment (RCM 기반 설비 고장 예측시스템)

  • Song, Gee-Wook;Kim, Bum-Shin;Choi, Woo-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1281-1286
    • /
    • 2010
  • Power plants have many components and equipment. It is difficult for operators to know the time of failure or the equipment that fails. Plants incur heavy economic losses due to unexpected failure. The equipment in power plants is constantly monitored by various sensors and instruments. However, prevention of failure is very difficult. Therefore, engineers are developing many types of failure-alarm systems that can detect the abnormal functioning of equipment. Such failure-alarm systems inform only about the abnormal functioning of equipment and do not indicate the cause of failure or the parts that have failed. In this study, we have developed a failure-prediction system that can provide details on the cause of trouble and the maintenance method.

A study on the cause Analysis and solution of an overheated NGR of the Main Transformer (변압기 중성점 접지리액터 과열원인분석 및 해소방안에 관한 연구)

  • Park, Gil-Soo;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.262-267
    • /
    • 2011
  • In the power system, the transformer's neutral earth reactor line 1 grounding failure may occur. By limiting the magnitude of the failure grounding current flow, it will aid to reduce the failure of the transformer. Consequently, this also may avoid the failure of the disconnection of the industrial insulator line that cause by melting. Besides, utilizing the decreasing circuit breaker or others related equipment can use to avoid the possibility of explosion of the transformer. If the failure happen during the operation of the power system, a huge interference will definitely may occur. Therefore, by installing the DONGBUSAN S/S #3M.Tr neutral earth reactor among TOP and BOTTOM BRACE part in the power system, the causes of the rising temperature and reason of the over-current flow that cause by over-current can be analyze.

Reoperation for prosthetic valve failure -clinical analysis of 15 cases- (인공심방판막실패에 대한 임상적 고찰)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.584-594
    • /
    • 1986
  • Despite the multivariate improvements in tissue treatment, material, and design of prosthetic heart valves in recent years, numerous complications that may lead to valve dysfunction remain a constant threat after valve replacement. Most common indications for prosthetic valve failure are primary valve failure, infective endocarditis, paravalvular leakage, and thromboembolism. From 1977 to 1986, 15 patients underwent reoperation for prosthetic valve failure in 278 cases of valve surgery. The etiology of prosthetic valve failure were primary valve failure in 12 patients [80 %], infective endocarditis in 2 patients [13.3 %], and a paravalvular leakage [6.7 %]. The average durations of implantation were 45.5 months; 53.9 months in primary valve failure, 16 months in infective endocarditis, and 4 months in paravalvular leakage. The rate of valve failure was high under age of 30 [11/15]. Calcifications and collagen disruption of prosthesis were main cause of primary valve failure in macro- & micropathology. Prosthesis used in reoperation were 5 tissue valves and 10 mechanical valves. Operative mortality were 13.3 % [2/15], due to intractable endocarditis and ventricular arrhythmia.

  • PDF

CAUSE OF TECHNICAL FAILURES OF CONICAL CROWN-RETAINED DENTURE (CCRD): A CLINICAL REPORT

  • Yi Yang-Jin;Cho Lee-Ra;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.714-719
    • /
    • 2003
  • Conical crown-retained denture (CCRD) has been used as a very effective treatment method in cases with few remaining teeth with heterogeneous prognosis. However, in spite of many advantages of CCRD, high technical failure rate was a problem to be considered. Incorrect path of insertion and excessive retention were thought to be the main cause of technical failure and to result from laboratory procedure with a coping misfit and/or a coping transfer error. In order to prevent this error, secure anchoring of inner coping and re-examination and milling of convergence angle were recommended on the master model from pick-up impression.

Case Study of Intermittent Poor Acceleration Fault Diagnosis by Brake Switch Fault (브레이크 스위치 결함에 의한 간헐적인 가속불량 현상의 고장진단 사례연구)

  • Kim, Sung Mo;Jo, Haeng Deug
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.203-210
    • /
    • 2015
  • This paper investigates the failure of a car with a 2.5-liter CRDi engine of the Hyundai Company. The failure is caused by intermittent poor acceleration while driving. To analyze the cause, we investigated the air intake volume, the fuel injection, and the air-fuel ratio, which were determined to be normal. The brake switch signal error was discovered while analyzing the function that limits the output of the engine. While investigating the cause, we discovered the corrosion of the pins on the connector of the brake switch. We determined that it was generated by soapy water flowing in the solar film. Therefore, the cause of the failure was the brake switch signal errors. Additionally, we determined that ECM was the normal fail-safe mode that implemented the override device for safety during normal acceleration. Based on these results, further solar film experiments must be conducted to fully elucidate the causes.

Failure Analysis of Connecting Rod at Small End (커넥팅로드 소단부 파단의 해석)

  • 민동균;전병희;김낙수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.382-390
    • /
    • 1995
  • Failure of connecting rod in automotive engine may cause catastrophic situation. The corner radius at small end has an effect on stress raising. To investigate the stress distribution in connecting rod during operation, the finite element analysis was used by giving possible maximum tension and compression. Excessive sizing after forging connecting rod may result in the tensile residual stress which lower the fatigue life and cause premature failures. It was shown that when the sizing amount is too large, the location of high tensile residual stress coincide with that of high stress amplitude during operation through the elastic-plastic finite element analysis. The endurance limit moves down due to the surface finish and decarburization, which combines with the movement of resultant stress points to dangerous range. It was concluded that the precise control of sizing and enough corner radius are necessary to a reliability of connecting rod.