• Title/Summary/Keyword: Cause by case

Search Result 3,370, Processing Time 0.243 seconds

A Study on the Failure Characteristics about Metropolitan Pipelines in Korea (국내(國內) 대도시(大都市) 수도관(水道管)의 파손특성(破損特性)에 관한 연구(硏究))

  • Lee, Hyun-Dong;An, Youn-Joo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.1
    • /
    • pp.96-111
    • /
    • 1996
  • The failure of water pipelines is progressed by several compound factors and the collection and analysis of data about pipeline failure are inevitable for effective pipeline rehabilitation. Data analysis of pipeline failure was already performed in USA and Europe. Based on such phenomena, failure characteristics about metropolitan pipelines in Korea were analyzed: The conclusions of this study are as followings. 1. The failure cause of pipelines can be classified into natural cause and artificial cause. Artificial cause is 32% of total causes, so artificial failure as several constructions happens frequently in Korea. Although the failure by old pipe is greatest of any other causes m classtfied cause, failure cause is not classified in detail now. 2. The damaged part of pipelines is affected by cities, distribution system inventory, bedding conditions, and so on. In this study, the failure of pipeline body(67%) is greater than the failure of pipeline joint(33%) in natural failure. 3. In regard to pipe materials, failure rate of DCIP(0.8456), PEP(0.7288), and GSP(0.6643) is greater than that of CIP(0.3985) and CWSP(0.2348). 4. Usually, faIlure rate is increased in proportion to diameter of pipeline. In this study, CIP, DCIP, and CWSP have clear trends. But the trends of PEP is reverse, the case of GSP, HP is obscure due to data shortage. 5. There are no direct relationships between burial age and failure rate of pipelines. 6. Annual breaks and winter(Nov.~Feb.) breaks of pipelines are investigated. As a result, WInter breaks to annual breaks of CIP is 51.3%(Seoul), 51.1%(Taegu),38.7%(Pusan). This phenomena have direct correlation with average winter temp. of cities.

  • PDF

A Case Study for Analysis on Present Condition and Cause of Indoor Noise in University Cafeteria (대학교 학생식당의 실내소음 실태 및 원인 분석 사례연구)

  • Choi, Yoon-Jung;Lee, Seon-A;Kim, Hye-Kyeong
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.85-91
    • /
    • 2007
  • This is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to find out the present condition of physical level, type, and cause of indoor noise of cafeteria in university campus by comparison with a restaurant near campus. Research methods were field survey and questionnaire survey. Field survey was consisted of measurement on equivalent and instant noise level and observation on noise type. Respondents of questionnaire survey were 60 students using subject cafeteria or restaurant. Surveys were carried out in the 8th and in the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$ (average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$ (average 71.2) dB (A), exceeded the indoor noise recommended value of ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers). But noise levels of the restaurant were $61.6{\sim}70.4$ (average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$ (average 64.9) dB(A). 2) The users's responses on major noise type in the cafeteria were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'talcing noise', but 'taking noise' and 'background music' in the restaurant. 3) It was found that indoor noise level of the cafeteria was caused by sound reflection of finishing materials, noise diffusion by open type kitchen, and dragging noise of movable furniture.

Carbonization Characteristics of Phenolic Resin Deteriorated by Tracking (트래킹에 의해 열화된 페놀수지의 탄화 특성)

  • 송길목;최충석;노영수;곽희로
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This paper describes the carbonization characteristics of a phenolic resin deteriorated by tracking under the environment of a fire. In the experiment, a liquids droplet of 1[%] NaCl was dripped on the phenolic resin to cause a tracking with 110[V], 220[V] voltages applied. It can be addressed from the experimental results that when an insulator is carbonized by an external fire, its structure is amorphous. If an insulator is carbonized by electrical cause, on the other hand, its structure would be crystalline. In order to observe the surface change of the phenolic resin, the tracking process was analyzed by using SEM. In the case that the materials are carbonized under heat or fire, the exothermic peak appears around 500[$^{\circ}C$]. This is one of the important factors to determine the cause of fires. As a result of DTA, the exothermic peaks of an untreated sample showed at 333.4[$^{\circ}C$], 495.7[$^{\circ}C$] but those of a sample deteriorated by tracking appeared at 430.6[$^{\circ}C$], 457.6[$^{\circ}C$] in a voltage of 110[V], and at 456.2[$^{\circ}C$], 619.7[$^{\circ}C$] in a voltage of 220[V]. It is possible, therefore, to distinguish a virgin sample from carbonized samples(graphite) by the exothermic peak.

Development of a Probability Model for Burst Risks of Water Main using the Analysis Methods of Leakage Type (매설환경에 따른 배수관망의 누수발생원인 특성분석)

  • Park, Sang-Bong;Choi, Tae-Ho;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.141-152
    • /
    • 2011
  • In this study, we extracted effective factors of pipe burst from the status data of water asset, operating data of pressure, volume and etc. and 7 years' pipe burst and repair records. The extracted factors were sorted by each attribution and then a statistical analysis was performed to generate a pipe burst probability function using the logistic regression model. As the result, material, diameter, length, laying year, pressure and road width affected to pipe burst significantly. Especially, in case of small diameter, laying year was most effective factor and in case of steel pipe, external loading was main cause of burst, and in case of cast iron, PE, PC, HP pipes, the deterioration of joint was main cause. The other side, as a result of Hosmer-Lemeshow goodness of fit test the models are turned out significant statistically. Also the classification criteria were determined to minimize the total cost from classification errors, when the predicted probability was more than 18% this pipe could have a chance of burst.

The Analyses of Causes of Visibility Impairment in Pusan (부산지역 시정악화의 원인 분석)

  • Kim Yoo-Keun;Moon Yun-Seob;Bae Joo-Hyun;Kwak Jin
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.639-643
    • /
    • 1999
  • After analyzing the correlation between air pollution and visibility, TSP and $NO_2$ is responsible for poor visibility in Pusan. After analyzing the correlation between meteorological factors and visibility, general pattern of humidity has clear negative correlation. The variation of wind speed has a positive correlation. In order to investigate the cause of poor visibility in Pusan area, the Andersen sampler and PM-2.5 are used to collect and analyze aerosol. This study was carried out to monitor the visibility using Forward scattering meter and to find out the characteristics and the cause of good visibility case and poor visibility case by measuring and analyzing a variety of parameters, such as particle size distributions, chemical compositions, and meteorological conditions in Pusan. According to the analysis of intensive sampling, $NO_3^-,NH_4^+$ ion concentration increased together with the mass concentration around $0.5\~2.5{\mu}m$ approximately during the case of poor visibility. $NH_4NO_3,\;NH_4Cl,\;and\;NaCl$ were thought to be the major components of fine particles.

  • PDF

Effectiveness of non-linear fluid viscous dampers in seismically isolated buildings

  • Guler, Elif;Alhan, Cenk
    • Earthquakes and Structures
    • /
    • v.17 no.2
    • /
    • pp.191-204
    • /
    • 2019
  • Near-field earthquake records including long-period high-amplitude velocity pulses can cause large isolation system displacements leading to buckling or rupture of isolators. In such cases, providing supplemental damping in the isolation system has been proposed as a solution. However, it is known that linear viscous dampers can reduce base displacements in case of near-field earthquakes but at the potential expense of increased superstructure response in case of far-field earthquakes. But can non-linear dampers with different levels of non-linearity offer a superior seismic performance? In order to answer this question, the effectiveness of non-linear viscous dampers in reducing isolator displacements and its effects on the superstructure response are investigated. A comparison with linear viscous dampers via time history analysis is done using a base-isolated benchmark building model under historical near-field and far-field earthquake records for a wide range of different levels of non-linearity and supplemental damping. The results show that the non-linearity level and the amount of supplemental damping play important roles in reducing base displacements effectively. Although use of non-linear supplemental dampers may cause superstructure response amplification in case of far-field earthquakes, this negative effect may be avoided or even reduced by using appropriate combinations of non-linearity level and supplemental damping.

Thoracoabdominal injury with evisceration from a chainsaw assault: a case report

  • Salami, Babatunde Abayomi;Ayoade, Babatunde Adeteru;Shomoye, El-Zaki Abdullahi;Nwokoro, Chigbundu Collins
    • Journal of Trauma and Injury
    • /
    • v.35 no.2
    • /
    • pp.118-122
    • /
    • 2022
  • The usual cause of penetrating thoracoabdominal injuries with evisceration are stab wounds with knives and other sharp weapons used during fights and conflicts. Evisceration of the abdominal viscera as a result of trauma, with its attendant morbidity and mortality, requires early intervention. Gunshot wounds can also cause penetrating thoracoabdominal injuries. We report the case of a 52-year-old male patient, a worker at a timber-processing factory, who was assaulted with a chainsaw by his colleague following a disagreement. He was seen at the accident and emergency department of Olabisi Onabanjo University Teaching Hospital, Sagamu, Nigeria with a thoracoabdominal injury about 1.5 hours after the attack. He had a left thoracoabdominal laceration with abdominal evisceration and an open left pneumothorax. He was managed operatively, made a full recovery, and was discharged 16 days after admission. He was readmitted 4 months after the initial surgery with acute intestinal obstruction secondary to adhesions. He underwent exploratory laparotomy and adhesiolysis. He made an uneventful recovery and was discharged on the 9th postoperative day for subsequent follow-up.

A Case of the Laryngopharyngeal Burn Caused by A Microwave-Heated Egg Bite

  • Won, Seong Jun;Woo, Seung Hoon
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.2
    • /
    • pp.122-124
    • /
    • 2013
  • Nowadays, microwave ovens are commonly used for cooking. However, the cooking certain food in microwave ovens can be hazardous. It has been reported that the heating eggs in a microwave oven can cause an explosion and injuries. The exploding eggs can cause burn injury of face, neck, eyelid, pharynx and larynx. Direct thermal damage to the larynx after swallowing microwave-heated eggs is rare. The authors report a larynx thermal injury due to microwave-heated eggs and review the cause and the prevention methods of exploding eggs.

  • PDF

A Case Study on the Assessment of Damaged Cause for the Damaged Reinforced Concrete Pier

  • Chai, Won-Kyu;Kim, Kwang-Il;Son, Young-Hyun
    • International Journal of Safety
    • /
    • v.10 no.1
    • /
    • pp.16-21
    • /
    • 2011
  • In this thesis, appearance inspection, compressive strength of concrete test, arrangement of bar inspection, survey, and bearing stress analysis were performed on a damaged coping of reinforced concrete pier to investigate the damage cause. According to the performed a series of inspections, it was found that the coping of pier was damaged during PSC (Pre-stressed Concrete) beam construction. In this thesis, the repair method for damaged pier was studied. The repair procedure used in this thesis was follows : chipping for damaged part, clean by high-pressure, installation of wire mesh, coating of surface hardening, construction of section restoration material, copula grinding, and prevent coating for far-infrared radiation.

  • PDF

Acute Respiratory Failure during Splanchnic Nerve Block in COPD Patient (만성폐색성 폐질환 환자에서의 내장신경차단중 발생한 급성호흡부전)

  • Chang, Won-Young;Choe, Kun-Chun
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.200-204
    • /
    • 1991
  • Neurolytic splanchnic nerve block is a relatively safe and effective method for the relief of intractable pain caused by upper abdominal cancer. We have experienced a case of severe acute respiratory failure during splanchnic nerve block under control of X-ray fluoroscopy. We think that the most likely cause of the acute respiratory failure was an asthmatic attack due to anxiety and dyspnea from the injury or stimulation of the diaphragm and pleura in this case.

  • PDF