• Title/Summary/Keyword: Cation exchange membrane

Search Result 133, Processing Time 0.034 seconds

Electricity Generation and Microbial Community Structure Variation Depending on Separator Types and Cathode Characteristics in Air-cathode MFC (공기환원전극 미생물연료전지에서 분리막 종류 및 환원전극 특성에 따른 전기발생 및 미생물 군집구조 변화)

  • Yu, Jae-Cheul;Lee, Chang-Yeol;Kim, Sun-Ah;Cho, Hae-In;Cho, Sun-Ja;Lee, Tae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.2
    • /
    • pp.113-120
    • /
    • 2010
  • Air-cathode microbial fuel cell consisted of 4 unit cells were operated under batch condition and electricity generation and microbial community structure variation were investigated, depending on separator types and cathode characteristics: A) PEM(Proton Exchange Membrane)-30% Wet proofing Carbon Cloth(WC), B) AEM(Anion Exchange Membrane-WC, C) CEM(Cation Exchange Membrane)-WC, D) PEM-No Wet proofing Carbon Cloth(NC). Maximum power densities of PEM-WC, AEM-WC and CEM-WC were 510.9, 522.1 and 504.8 $mW/m^2$, respectively. But PEM-NC showed relatively lower maximum power density of 218.3 $mW/m^2$. And PEM-WC, AEM-WC and CEM-WC showed similar internal resistances(20.0-28.2 ${\Omega}$). PCRDGGE, PCA and diversity indices showed that uncultured bacteria which reported in previous MFC studies were detected in suspended growth bacteria and attached growth bacteria would be affected not by separator type but by cathode characteristic. Thus, cathode characteristic can be one of the critical factors for power generation in air-cathode MFC using PEM, AEM, and CEM as separator.

Performance Study of Membrane Capacitive Deionization Installed with Sulfonated Poly(ether ether ketone) and Poly(vinyl amine)/poly(vinyl alcohol) Membranes (Sulfonated Poly(ether ether ketone) 및 Poly(vinyl amine)/poly(vinyl alcohol) 혼합막이 장착된 막결합형 축전식 탈염공정의 성능 연구)

  • Kim, Ka young;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.62-69
    • /
    • 2016
  • In this study, sulfonated poly(ether ether ketone) (SPEEK) as cation exchange membrane and blended and crosslinked poly(vinyl amine) (PVAm) with poly(vinyl alcohol) (PVA) membrane as anion exchange membrane were used and then the performance experiments of the membrane capacitive deionization (MCDI) installed with both membranes were carried out. The newly prepared anion exchange membrane were characterized through water content, ion exchange capacity and FT-IR. The crosslinking time of 3 h to 5 h indicated that the salt removal was reduced from 81.3, 65.7% to 53.8%. The effect of PVAm contents from 40, 60, to 80% on the salt removal was shown 81.3, 75.2 and 37.7%, respectively. As a result, it was concluded that the crosslinking time and the content of PVAm had an influence on the salt removal efficiency.

A Comparison between C4 and Cation-exchange Columns as a Pre-separation Method for Mass Spectrometric Analysis to Characterize a Global Identification of Phosphopeptides and Phosphorylation Sites (세포내 총체적인 인산화 펩타이드 및 인산화 위치 규명을 위해 질량분석기 전 단계의 C4 및 양이온 교환수지 칼럼 이용 방법의 비교)

  • Kim, Hye-Jeong;Baek, Moon-Chang
    • YAKHAK HOEJI
    • /
    • v.59 no.3
    • /
    • pp.113-119
    • /
    • 2015
  • Protein phosphorylation is one of most important post-translational modifications (PTMs) and plays an important role in regulation of protein function. Here we develop a method for a global identification of phosphopeptides and phosphorylation sites using nano-LC MS/MS. We compared two separation methods, C4 and strong cation ion exchange (SCX). Before phosphopeptides enrichment with $TiO_2$, total proteins from Rat 1 cells have been separated using C4 column or tryptic peptides of proteins from the cells have been separated using SCX column. Finally, we have detected 52 phosphorylation sites on 41 proteins from SCX method and 375 phosphorylation sites on 252 proteins from C4 method, and determined the function and localization of identified phosphoproteins using DAVID software. In particular, we showed new phosphorylation sites from membrane proteins related to various cell signaling mechanisms. This method may contribute to study global signal networks induced by various signals including ligands and drugs.

Preparation and Properties of Heterogeneous Cation Exchange Membrane for Recovery of Ammonium Ion from Waste Water (폐수중 암모늄 이온 회수를 위한 불균질 양이온교환막의 제조 및 특성)

  • Jeong, Boo-Young;Song, Sang-Hun;Baek, Ki-Wan;Cho, In-Hee;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.486-491
    • /
    • 2006
  • Heterogeneous membranes were prepared by compression molding for the recovery of ammonium ion from waste water. Degree of sulfonation for sulfonated ion exchange resin increased with increasing amount of chlorosulfonic acid. It was 3.32 meq/g at 10 vol%. The tensile strength and elongation of the heterogeneous membrane was decreased with increasing contents of ion exchange resin. The tensile strength for LLDPE matrix membrane was the highest and also the elongation for EVA matrix membranes were the highest. The water content of heterogeneous membrane was increased with increasing contents of ion exchange resin. The maximum value of transport number for PE matrix membrane was 0.973. The electrical resistance of LLDPE matrix membrane was the lowest. It was value of $10.36{\Omega}/cm^2$ at 70 wt% resins.

Controlling Water Splitting Characteristics of Anion-Exchange Membranes by Coating Imidazolium Polymer (이미다졸륨 고분자 코팅을 통한 음이온교환막의 물분해 특성 제어)

  • Kim, Do-Hyeong;Park, Jin-Soo;Kang, Moon-Sung
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.152-161
    • /
    • 2015
  • In this study, novel pore-filled anion-exchange membranes (PFAEMs) with low electrical resistance, high permselectivity, and low water-splitting flux property under a concentration polarization condition have been developed for the enhancement in the efficiency of electrochemical water treatment processes. The base membranes have been prepared by filling a copolymer containing quaternary ammonium groups with an excellent ion-exchange capability into a porous polyolefin substrate, showing a high performance superior to that of a commercial membrane. In addition, it was confirmed that the electrochemical membrane performances are preserved while the water-splitting flux is effectively controlled by coating an imidazolium polymer onto the surface of the base membrane. The prepared PFAEMs revealed remarkably low electrical resistances of about 1/6~1/8 compared to those of a commercial membrane, and simultaneously low water-splitting flux comparable with that of cation-exchange membranes under a concentration polarization condition.

Preparation and Characterizations of Ionomer-coated Pore-filled Ion-exchange Membranes for Reverse Electrodialysis (역전기투석 응용을 위한 이오노머가 코팅된 세공충진 이온교환막의 제조 및 특성분석)

  • Kim, Do-Hyeong;Kang, Moon-Sung
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.43-54
    • /
    • 2016
  • In this study, we have prepared engineering polymer-based ionomers and pore-filled ion-exchange membranes (PFIEMs) employing a porous polyethylene substrate and combined them to fabricate the ionomer-PFIEM composite membranes for the reverse electrodialysis (RED) application. Both the electrochemical properties comparable to those of the commercial ion-exchange membranes (AMX/CMX, Astom Corp., Japan) and the physical stability adaptable to the practical uses have been achieved by integrating the ionomers having a high ion conductivity and the PFIEMs with an excellent mechanical strength. The RED performances have been evaluated by employing the prepared ionomer-PFIEM composite membranes and therefore excellent power generation performances were shown as the levels of 86.4% and 104.8% for the anion-exchange membrane and cation-exchange membrane, respectively, compared with those of the commercial membranes.

Preparation and Property of SBS Ion-exchange Membrane Via Post-sulfonation (Post-sulfonation에 의한 SBS 이온교환막의 제조 및 특성)

  • Choi, Yongjae;Hwang, Eui Hwan;Hwang, Taek Sung
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.731-736
    • /
    • 2010
  • In this study, the sulfonated SBS cation-exchange membrane was prepared by post-sulfonation. Degree of sulfonation(DS), water-uptake, ion exchange capacity and electrical resistance and conductivity of sulfonated SBS were investigated as a function of sulfonation time. The DS of sulfonated SBS membrane was increased with increasing the reaction time and concentration of sulfuric acid. The maximum value of DS was 24.0%. And also, the water uptake and ion exchange capacity of the sulfonated SBS membrane were increased as increasing the value of DS. The values of water uptake and IEC were 41.2% and 0.80 meq/g, respectively. The electrical resistance and conductivity of the membrane showed $23.6{\Omega}{\cdot}cm^2$ and $4.24{\times}10^{-4}S/cm$, respectively.