• Title/Summary/Keyword: Cathode polarization

Search Result 148, Processing Time 0.028 seconds

Use of Inner Ionomer Solution in Preparing Membrane-Electrode Assembly (MEA) for Fuel Cells and Its Characterization

  • Seo, Seok-Jun;Woo, Jung-Je;Yun, Sung-Hyun;Park, Jin-Soo;Moon, Seung-Hyeon
    • Korean Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.46-52
    • /
    • 2008
  • Optimization of ionomer solution was conducted in order to improve the performance of MEAs in PEMPC. The interface between membrane and electrodes in MEAs is crucial region determining fuel cell performance as well as ORR reaction at cathode. Through the modification of Nafion ionomer content at the interface between membrane and electrodes, an optimal content was obtained with Nafion 115 membranes. Two times higher current density was obtained with the outer Nafion sprayed MEA compared with the non-sprayed one. In addition, the symmetrical impedance spectroscopy mode (SM) exhibited that the resistances of membrane area, proton hydration, and charge transfer decreased as the outer Nafion is sprayed. From the polarization curves and SM, the highest current density and the lowest resistance was obtained at the outer ionomer content of $0.15\;mg\;cm^{-2}$.

Investigation on Electrochemical Characteristics of Metallic Bipolar Plates with Chloride Concentrations for PEMFC (고분자 전해질 연료전지 금속 분리판용 금속의 염화물 농도에 따른 전기화학적 특성 연구)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.347-360
    • /
    • 2021
  • Currently, the demand for eco-friendly energy sources is high, which has prompted research on polymer electrolyte membrane fuel cells. Both aluminum alloys and nickel alloys, which are commonly considered as materials of bipolar plates in fuel cells, oxide layers formed on the metal surface have excellent corrosion resistance. In this research, the electrochemical characteristics of 6061-T6 aluminum alloy and Inconel 600 were investigated with chloride concentrations in an acid environment that simulated the cathode condition of the PEMFC. After potentiodynamic polarization experiments, Tafel analysis and surface analysis were performed. Inconel 600 presented remarkably good corrosion resistance under all test conditions. The corrosion current density of 6061-T6 aluminum alloy was significantly higher than that of Inconel 600 under all test conditions. Also, 6061-T6 aluminum alloy and Inconel 600 presented uniform corrosion and intergranular corrosion, respectively. The Ni, Cr, and Fe, which are the main chemical compositions of Inconel 600, are higher than Al in the electromotive force series. And a double oxide film of NiO-Cr2O3, which is more stable than Al2O3, is formed. Thus, the corrosion resistance of Inconel 600 is better.

Eelectrochemical Performance of Perovskite Materials coated Cathode for MCFC (perovskite 물질이 코팅된 MCFC용 공기극의 전기화학적 성능 고찰)

  • Song, Shin Ae;Kang, Min Gu;Yoon, Sung Pil;Han, Jong Hee;Oh, In Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.133.2-133.2
    • /
    • 2010
  • 현재 융융탄산염 연료전지의 공기극으로 다공성의 lithiated NiO를 사용하고 있는데 이 재료의 경우 크게 두 가지의 문제점을 안고 있다. 첫 번째는 Ni이 전해질 내로 용해하는 것이고, 두 번째는 낮은 활성으로 인한 높은 공기극의 분극이다. Ni이 전해질로 용해되는 문제는 Co나 Fe를 코팅하여 공기극 표면에 $Li_x(Ni_yCo_{1-y})1-xO_2$$Li_x(Ni_yFe_{1-y})_{1-x}O_2$를 형성시켜 NiO의 전해질 내로 용해되는 것을 억제하는 방법이나 ZnO, MgO, $La_2O_3$ 등의 산화물을 NiO 표면에 코팅하여 전해질과 접촉을 막는 방식으로 해결하는 등 많은 연구가 이루어져 왔다. 하지만 연료극의 비해 상당히 높은 공기극의 분극으로 인해 큰 전압손실이 일어나 용융탄산염 연료전지 성능이 낮아지는 문제의 경우 이를 해결하고자 하는 연구는 상대적으로 많이 진행되지 못한 상태이다. 특히 현재 용융탄산염 연료전지의 장기수명화를 위해 기존의 작동온도인 $650^{\circ}C$ 보다 다소 낮은 온도인 $600{\sim}620^{\circ}C$에서 작동하려는 움직임이 있다. 작동 온도가 내려가면 전해질이 휘발되는 속도가 낮아져 전해질 부족에 따른 운전시간이 줄어드는 문제를 해결할 수 있어 장기 수명화를 위해서는 작동온도를 낮추는 것이 매우 유리하다. 하지만 작동 온도가 내려가면서 양 전극에서 일어나는 전기화학 반응 속도가 느려지기 때문에 각 전극에서의 활성화 분극으로 인한 전압손실은 더욱 커질 수밖에 없다. 특히 연료극의 수소산화반응 속도는 공기극의 산소환원반응에 비해 매우 빠르기 때문에 작동 온도가 내려감에 따라 연료극의 분극이 커지는 것에 비해 공기극의 분극이 급격히 커지게 된다. 따라서 운전온도가 낮아지는 상황에서는 낮은 작동온도에서도 성능감소가 적게 일어나 0.8V 이상 운전(150mA/$cm^2$, 단위전지 기준)이 가능한 공기극의 개발이 매우 필요한 실정이다. 이를 해결하고자 본 연구에서는 고체 산화물 연료전지의 공기극의 재료로 많이 연구되고 있는 혼합전도성 물질의 페로브스카이트 구조의 물질을 기존 NiO 전극에 코팅하여 새로운 공기극을 개발하였다. 페로브스카이트 구조의 물질로 대표적인 LSCF 물질을 사용하였으며 LSCF를 코팅한 공기극을 이용한 단위전지에서 150mA/$cm^2$의 전류를 흘려주었을 때 0.84V의 성능을 1000hr 유지하였다. 이는 기존의 NiO 전극을 사용했을 때보다 15~20mV 높은 값이다. 낮은 작동온도에서도 좋은 성능을 보였는데, 기존의 NiO 전극의 경우 $630^{\circ}C$에서 0.79V의 성능을 보인 반면 LSCF가 코팅된 공기극의 경우 $620^{\circ}C$에서 0.811V의 매우 좋은 성능을 보였다. 이는 LSCF의 산소이온전도성 및 전기전도성이 공기극에서의 분극을 낮추어 성능을 증가시키는 것으로 보인다.

  • PDF

Characteristics of Pr1-xMxMnO3(M=Ca, Sr) as a Cathode Material of Solid Oxide Fuel Cell (고체전해질형 연료전지용 Pr1-xMxMnO3(M-Ca, Sr) 산소극 재료의 특성)

  • Rim, Hyung-Ryul;Jeong, Soon-Ki;Lee, Ju-Seong
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1125-1131
    • /
    • 1996
  • Ca or Sr-doped $PrMnO_3$ were prepared for cathode material of solid oxide fuel cell. The characteristics such as the electrical conductivity and the cathodic overpotential were investigated as to doping contents. Also the reactivity with yttria stabilized zirconia of electrolyte, and the thermal expansion coefficient were studied. The prepared perovskite powder had the mean particle size of $2{\sim}5{\mu}m$, and the particle size and the surface area was out of relation to the doping content. When Ca doping amount of electrode material was 30mol%, the electrical conductivity was the highest value of $266S{\cdot}cm^{-1}$ at $1000^{\circ}C$, and also the polarization characteristics showed the best property. The reactivity between YSZ and Ca-doped $PrMnO_3$ at $1200^{\circ}C$ for 100hours was lower than that between YSZ and Sr-doped $PrMnO_3$. The thermal expansion coefficient of $Pr_{0.7}Ca_{0.3}MnO_3$ was $1.19{\times}10^{-5}K^{-1}$ in the temperature range of $300{\sim}1000^{\circ}C$, and this value was similar to that of YSZ, $1.15{\times}10^{-5}K^{-1}$.

  • PDF

Effect of SUS316L Bipolar Plate Corrosion on Contact Resistance and PEMFC Performance (SUS316L 분리판 부식에 의한 접촉저항 및 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.664-670
    • /
    • 2021
  • Stainless steel was applied as bipolar plate (BP) of polymer electrolyte membrane fuel cell (PEMFC) due to high mechanical strength, electrical conductivity, and good machinability. However, stainless steel was corroded and increased contact resistance resulting PEMFC performance decrease. Although the corrosion resistance could be improved by surface treatment such as noble metal coating, there is a disadvantage of cost increase. The stainless steel corrosion behavior and passive layer influence on PEMFC performance should be studied to improve durability and economics of metal bipolar plate. In this study, SUS316L bipolar plate of 25 cm2 active area was manufactured, and experiments were conducted for corrosion behavior at an anode and cathode. The influence of SUS316L BP corrosion on fuel cell performance was measured using the polarization curve, impedance, and contact resistance. The metal ion concentration in drained water was analyzed during fuel cell operation with SUS316L BP. It was confirmed that the corrosion occurs more severely at the anode than at the cathode for SUS316L BP. The contact resistance was increased due to the passivation of SUS316L during fuel cell operation, and metal ions continuously dissolved even after the passive layer formation.

H2S Poisoning Effect and Recovery Methods of Polymer Electrolyte Membrane Fuel Cell (황화수소 피독이 고분자전해질 연료전지에 미치는 영향과 회복기법)

  • Chun, Byungdo;Kim, Junbom
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.107-114
    • /
    • 2017
  • The performance of polymer electrolyte membrane fuel cell (PEMFC) could be deteriorated when fuel contains contaminants such as carbon monoxide (CO) or hydrogen sulfide ($H_2S$). Generally, $H_2S$ is introduced in hydrogen by steam reforming of hydrocarbon which has mercaptan as odorant. $H_2S$ poisoning effect on PEMFC performance was examined on this study. Pure hydrogen injection, voltage cycling and water circulation methods were compared as performance recovery methods. The PEMFC performance was analyzed using electrochemical methods such as polarization curve, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Pure hydrogen injection and voltage cycling methods showed low recovery ratio, however, water circulation method showed high recovery ratio over 95%. Because anode was directly poisoned by $H_2S$, anode water circulation showed higher recovery ratio compared to the other methods. Water circulation method was developed to recover PEMFC performance from $H_2S$ poisoning. This method could contribute to PEMFC durability and commercialization.

Coolant Leak Effect on Polymer Electrolyte Membrane Fuel Cell (고분자전해질연료전지의 냉각수 누설에 대한 연구)

  • Song, Hyun-Do;Kang, Jung-Tak;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of polymer electrolyte membrane fuel cell could be decreased due to coolant leaked from connection part. Micro pump was used to put small amount of coolant and investigate the effect on fuel cell. The stoichiometric ratio of hydrogen/air was 1.5/2.0, both side of gas was fully humidified, and current density of $400mA/cm^2$ was used as standard condition in this experiment. Constant current method was used to check performance recovery from coolant effect in 3 cell stack. The performance was recovered when coolant was injected in cathode side. On the other hand, the performance was not recovered when coolant was injected in anode side. Ethylene glycol could be converted to CO in oxidation process and cause poisoning effect on platinum catalyst or be adhered on GDL and cause gas diffusion block effect resulting performance decrease. Water with nitrogen gas was supplied in anode side to check performance recovery. Polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy was used to check performance, and gas chromatography was used to check coolant concentration. Constant current method was not enough in full recovery of performance. However, water injection method was proved good method in full recovery of performance.

A Study on the Optimum Operating Conditions and Effects of Wastewater Characteristics in Electrochemical Nitrogen Removal Process (질소 제거를 위한 전기화학적 처리 공정의 최적 운전조건 및 폐수 성상에 따른 영향에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon;Song, Su-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • This study was performed under four operational conditions for nitrogen removal in metal finishing wastewater. The conditions include electrode gap, reducing agent, the recycling of treated wastewater in 1st step and the simultaneous treatment of nitrate and other materials. Result showed that the removal efficiency of $NO_3{^-}-N$ was highest at the electrode gap of 10 mm. As the electrode gap was shorter than 10 mm, the removal efficiency of $NO_3{^-}-N$ decreased due to increasing in concentration polarization on electrode. And, in case that the electrode gap was longer than 10 mm, the removal efficiency of $NO_3{^-}-N$ increased with an increase in energy consumption. Because hydrogen ions are consumed when nitrate is reduced, reducing reaction of nitrate was effected more in acid solution. As 1.2 excess amount of zinc was injected, the removal efficiency of $NO_3{^-}-N$ increased due to increasing in amount of reaction with nitrate. As the effluent from 1st step in the reactor was recycled into the 1st step, the removal efficiency of $NO_3{^-}-N$ increased. Because the zinc were detached from the cathode and concentration-polarization was decreased due to formation of turbulence in the reactor. The presence of $NH_4{^+}-N$ did not affect the removal efficiency of $NO_3{^-}-N$ but the addition of heavy metal decreased the removal efficiency of $NO_3{^-}-N$. As chlorine is enough in wastewater, the simultaneous treatment of nitrate and ammonia nitrogen may be possible. The problem that heavy metal decrease the removal efficiency of $NO_3{^-}-N$ may be solved by increasing current density or using front step of electrochemical process for heavy metal removal.

The optical character analysis of the direct typed BLU for LCD TV

  • Yoon, D.K.;Park, D.S.;Han, J.M.;Oh, Y.S.;Bae, K.W.;Kim, Y.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1058-1061
    • /
    • 2004
  • Recently, According to companies of TFT LCD are making large sized products more and more. In the vortex of Products with a monitor and LCD TV is applied in a technique of a high viewing angle(FFS, IPS, VA). Also, as a high luminance, high speed response time, high degree of a color purity, and so on are continuing to develop a high performance, it is necessary to improve a specific character of high luminance that apply to LCD TV as a LCD BLU. Because a LCD panel for TV usually has a lower resolution that compare to a monitor, the structure of present backlight system can't put out its power even though it has a merit in transmission. Therefore, the examination of improvement about the high luminance direct typed BLU for LCD TV that presupposes several uses of CCFL(Cold Cathode Fluorescent Lamp) or EEFL(External Electrode Fluorescent Lamp)is actively being progressed. Although it is necessary to increase the number of lamps for applying high performance by the direct type, in this case, because we can design the character of luminance for adoption of high performance. We can satisfy with a level of luminance for LCD TV. Accordingly, we analyzed a change of the number of CCFL, mechanical and optical character to produce the direct typed backlight in 32inches spec. Consequently, we achieved luminance of 6597nit,which was including polarization film, and secured the standard for LCD TV.

  • PDF

The Influence of Impurities in Room Temperature Ionic Liquid Electrolyte for Lithium Ion Batteries Containing High Potential Cathode (고전압 리튬이차전지를 위한 LiNi0.5Mn1.5O4 양극용 전해질로써 상온 이온성 액체 전해질의 불순물 효과에 관한 연구)

  • Kim, Jiyong;Tron, Artur V.;Yim, Taeeun;Mun, Junyoung
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.2
    • /
    • pp.51-57
    • /
    • 2015
  • We report the effect of the impurities including water and bromide in the propylmethylpyrrolidinium bis(trifluoromethanesulfonyl)imide (PMPyr-TFSI) on the electrochemical performance of lithium ion batteries. The several kinds of PMPyr-TFSI electrolytes with different amount of impurities are applied as the electrolyte to the cell with the high potential electrode, $LiNi_{0.5}Mn_{1.5}O_4$ spinel. It is found that the impurities in the electrolytes cause the detrimental effect on the cell performance by tracing the cycleability, voltage profile and Coulombic efficiency. Especially, the polarization and Coulombic efficiency go to worse by both impurities of water and bromide, but the cycleability was not highly influenced by bromide impurity unlike the water impurity.