• 제목/요약/키워드: Catenary system

검색결과 411건 처리시간 0.025초

기존선 속도향상을 위한 틸팅차량시스템 기술사양(안) 제시 연구 (Technical specification of Tilting train EMU for speed UP on existing lines)

  • 한성호;박광복;이수길;유원희;엄기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1298-1300
    • /
    • 2002
  • This paper suggested that the technical specification of tilting train EMU for speed up on existing lines. High speed strategy of existing lines are the modification of railway system which are made on cant, lengths of transition curves, the catenary system and train system. Tilting technology is more useful a strategy for speed increases on existing lines with low investment needed. We performed a feasibility study which is considered out real track conditions and designed propulsion and braking system of tilting EMU system.

  • PDF

고속전철용 집전시스템의 동적해석 (Dynamic Analysis of Current Collection System in High Speed Train)

  • 최연선;최진민;경진호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 추계학술대회논문집; 한국종합전시장, 24 Nov. 1995
    • /
    • pp.142-147
    • /
    • 1995
  • Dynamic characteristics of current collection system is one of the major factors which decide the performance of high speed train. To find good design parameters of the current collection system design guide is prepared through the engineering analysis in this study. The analysis starts from the statics of catenary system which results in the sinusoidal variation of stiffness, which is inherently nonlinear Mathieu equation. Simple physical models of rigid trolley wire and Mathieu equation are considered. To simulate the dynamic response of current collection system, numerical integration based on central difference method and modal analysis are presented. The calculated results of central difference method show superior to those of Euler based algorithm.

  • PDF

Harmonic Analysis Model based on PSCAD/EMTDC

  • Lee, Han-Min;Lee, Chang-Mu;Jang, Gil-Soo;Kwon, Sae-Hyuk
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.115-121
    • /
    • 2004
  • This paper presents the model for an AC electric railway system using the PSCAD/EMTDC program. It is composed of a scott-transformer, an auto-transformer, catenary and electric trains, etc. After obtaining the models of the fundamental elements describing the AC electric railway system and its behavior, we have analyzed and tested an actual AC electric railway system focused on the amplification of harmonic current to verify the proposed model. The simulation results from the proposed approach and the measurement data from the test are described.

공항철도의 운영가용도 향상을 위한 RCM 활동 (RCM Activities for Improvement of Availability of AREX Railway System)

  • 이창환;임성수;송미옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.742-747
    • /
    • 2008
  • This paper is described the systematic activities of RCM to improve the availability for AREX railway system. The purpose of these activities are to maintain and enhance the reliability, availability, maintainability and safety, and to implement the effective maintenance for electrical and mechanical system including rolling stock, signalling, telecommunication, power supply, overhead catenary and platform screen door with impact to train operation.. The main activities consist of systematic failure and repair recording by integral information system, analysis and corresponding countermeasure. As applying these activities in opeartion and maintenance works, the availability of AREX railway system is going on improvement gradually, and maintenacne works are improved with these results.

  • PDF

철도차량 검측모듈의 신뢰성 검증 시험 연구 (A Study of Inspection Module for Verifying Reliability on Railway Vehicle)

  • 나경민;박영;권삼영
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1155-1161
    • /
    • 2017
  • This study examines environmental performance of the arcing measurement module according to international standards. The module assesses the collected current performance using a computer system. The module is required to assess environmental impact resulting from electromagnetic waves, shock and temperature change during train operation. The test includes testing EMI/EMC, vibration, shock and temperature cycling for interface between trains and the arcing measurement module. The module test items were determined in compliance with the standards suggested by the International Electrotechnical Commission (IEC) and Europaische Norm (EN). This study describes the method of test, test equipment operation and how to choose relevant performance standards. The analysis and test results of environmental performance for the module based on computer system are described in this study.

전차선로 가선재료의 부식특성 (Corrosion Characteristics of Catenary Materials in Electric Railway System)

  • 김용기;윤상인;장세기;이재봉
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.535-542
    • /
    • 2000
  • 전차선로 가선재료에는 순수구리로 이루어진 전차선, 카드뮴이 포함된 조가선, steel과 Al의 이종금속으로 이루어진 ACSR이 있고 이들 재료는 산성비와 같은 부식환경에 노출되어 있다. 따라서 다양한 부식환경에서의 이들 재료의 부식특성 및 부식속도를 규명하는 것은 매우 중요한 일이다 이에 본 실험에서는 pH, 용존산소 및 염소이온의 영향을 동전위분극시험, 선형분극시험, 교류임피던스시험 및 갈바닉시험 등의 전기화학적 분석기법을 통해 가선재료의 부식거동 및 부식속도를 조사하였다. 실험 결과 카드뮴이 함유된 재료의 부식저항성이 순수구리로 이루어진 재료에서의 부식저항성보다 낮은 것을 확인하였고, 염소이온이 내식성을 감소시킨다는 것을 관찰하였으며, 갈바닉시험 결과 산성용액에서 염소이온을 첨가하였을 경우 steel의 높은 갈바닉부식 전류밀도를 ZRA 법을 통해 확인하였다.

  • PDF

An experimental study of a circular cylinder's two-degree-of-freedom motion induced by vortex

  • Kim, Shin-Woong;Lee, Seung-Jae;Park, Cheol-Young;Kang, Donghoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권4호
    • /
    • pp.330-343
    • /
    • 2016
  • This paper presents results of an experimental investigation of vortex-induced vibration (VIV) of a flexibly mounted and rigid cylinder with two-degrees-of-freedom with respect to varying ratio of in-line natural frequency to cross-flow natural frequency, $f^*$, at a fixed low mass ratio. Combined in-line and cross-flow motion was observed in a sub-critical Reynolds number range. Three-dimensional displacement meter and tension meter were used to measure dynamic responses of the model. To validate the results and the experiment system, x and y response amplitudes and ratio of oscillation frequency to cross-flow natural frequency were compared with other experimental results. It has been found that the higher harmonics, such as third and more vibration components, can occur on a certain part of steel catenary riser under a condition of dual resonance mode. In the present work, however, due to the limitation of a size of circulating water channel, the whole test of a whole configuration of the riser at an adequate scale for VIV phenomenon was not able to be conducted. Instead, we have modeled a rigid cylinder and assumed that the cylinder is a part of steel catenary riser where the higher harmonic motions could occur. Through the experiment, we have found that even though the cylinder was assumed to be rigid, the occurrence of the higher harmonic motions was observed in a small reduced velocity ($V_r$) range, where the influence of the in-line response is relatively large. The transition of the vortex shedding mode from one to another was examined by using time history of x and y directional displacement over all experimental cases. We also observed the influence of in-line restoring force power spectral density with $f^*$.

전동차 회생에너지 활용을 위한 저장시스템 적용기술 연구 (A study on technical application of recycle energy storage system for electric rail car)

  • 김길동;이한민;오세찬;이장무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.307-309
    • /
    • 2006
  • There are operated the six thousand train in the interior of a country. 95% of them are possible usage of resuscitation. Especially, Among them VVVF-Inverter vehicle has a merit of the highest recycle rate. but we don't use a apt recycled energy. Although the existing recycle energy used inverter method supply with electric power, it is decided in accordance with the state of sources. So efficiency of recycled electric power is of poor quality and catenary-voltage-fluctuation be generate because of recycled electric power. and it is able to affect system of safety train service. We'll research the method of supply according to wire condition after storing recycle energy made during train's stopping relation to Advanced EMU Research. Those methods are divided SMES, Fly-Wheel and Supercapacitor, and Considering the both economical efficiency and system application, we'll develop recycle energy storage system suitable our country condition.

  • PDF

전기철도 전력시설 진단용 원격진단시스템 구축을 위한 네트워크 설계 (Network Design for Construction of Remote Diagnosis System for Power Facilities of Electric Railway)

  • 김재문;김양수
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.432-436
    • /
    • 2009
  • This paper is described that advanced study on network design of remote diagnosis system for power facilities of electric railway. In the field, it is very difficult for worker to diagnosis power facilities including catenary because workers should be maintenance on AC power supply. Therefore, to properly design on remote diagnosis system, we have searched the inside and outside of the country-related technology trends. Also we confirmed that required technologies to design interface technology required for the development of sensor devices and the USN network was designed in accordance with required skills. Throughout variety of requirements, we have development iRFS based ZA sensors and iRFM to receive data of sensor. Also CC2420 is applied as single-chip which used 2.4GHz IEEE802.15.4 compliant RF tranciver designed for low-power and low-voltage wireless applications for ZigBee communication.

Field Tests of DC 1500 V Stationary Energy Storage System

  • Lee, Hanmin;Kim, Gildong;Lee, Changmu;Joung, Euijin
    • International Journal of Railway
    • /
    • 제5권3호
    • /
    • pp.124-128
    • /
    • 2012
  • The ESS(energy storage system, here after) for a DC 1500V was developed in 2009. A ESS was installed on the track of Daejeon HRT in 2010. The advantage of the ESS is that it can save the energy and plus stable the catenary voltage. This paper presents the energy saved by the ESS in Daedong substation. When the ESS is on/off, the field tests are performed.