• Title/Summary/Keyword: Casualties

Search Result 784, Processing Time 0.023 seconds

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

Extraction of Landslide Risk Area using GIS (GIS를 이용한 산사태 위험지역 추출)

  • Park, Jae-Kook;Yang, In-Tae;Park, Hyeong-Geun;Kim, Tai-Hwan
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.1
    • /
    • pp.27-39
    • /
    • 2008
  • Landslides cause enormous economic losses and casualties. Korea has mountainous regions and heavy slopes in most parts of the land and has consistently built new roads and large-scale housing complexes according to its industrial and urban growth. As a result, the damage from landslides becomes greater every year. In summer, landslides frequently occur due to local torrential rains and storms. It is critical to predict the potential areas of landslides in advance and to take preventive measures to minimize consequences and to protect property and human life. The previous study on landslides mostly focused on identifying the causes of landslides in the areas where they occurred, and on analyzing landslide vulnerability around the areas without considering rainfall conditions. Thus there were not enough evaluations of the direct risk of landslides to human life. In this study, potentially risky areas for landslides were identified using the GIS data in order to evaluate direct risk on farmlands, roads, and artificial structures that were closely connected to human life. A map of landslide risk was made taking into account rainfall conditions, and a land use map was also drawn with satellite images and digital maps. Both maps were used to identify potentially risky areas for landslides.

The Eire Risk Assessment in Compressed Natural Gas Buses & Gas Station (CNG 버스 및 충전소의 화재 위험도 평가)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.57-67
    • /
    • 2004
  • The results of the risk assessing on general buses, consisting mainly of diesel-fueled buses, show that the frequency of the instantaneous release is 1.4${\times}$10$^{-3}$ /bus/year, from which the probability of the formation of fireball as a sub event becomes 1.7${\times}$104, and show that the leakage from the CNG-fueled buses is 0.002 event/year. Also, the frequency of gradual release due to a crack is estimated at 3.7${\times}$10$^{-3}$ /buses/year, and a subsequent probability at which this could lead to a jet flame as a sub event is 1.2${\times}$10$^{-3}$ This corresponds to 0.04event/year for the CNG-fueled buses. Dividing all the fired casualties by the running distance of diesel-fueled buses, the risk is 0.091 fire fatalities per 100-million miles. And the total fire risk fur CNG buses is approximately 0.17 per 100-million miles of travel. This means that CNG buses is twice or more dangerous than diesel buses. After all CNG buses are more susceptible to the major fires. In the aspect of the reliability of this study, generic models and the failure data used in assessing the risks of CNG buses are appropriate. However, more accurate physics-based models and databases should be supplemented with this study to provide the better results.

A Study for Performance Improvement of Fire Detector and Sprinkler Head in Apartment Houses (공동주택 화재감지 및 소화성능개선에 관한 연구)

  • Lee, Chae-Won;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This study suggested the problems and their improvement measures for the operation of fire detectors and sprinkler heads installed at apartment houses. According to a census on population and housing in 2010, apartment houses account for 71.6% of the total housing facilities. And by fire statistics data of the National Emergency Management Agency, approximately 25.0% of fire accidents and 46.4% of casualties occur at apartment houses every year. Therefore, this study conducted for identifying the causes and characteristics of fire to establish the fire safety improvement measures for apartment houses. And this study was carried out virtual fire simulation at domestic apartment houses. The scenario of the simulation contains a comparative analysis on the operation time of standard sprinkler heads and residential sprinkler heads, heat detectors and smoke detectors. As a result of simulation, it was found that standard sprinkler heads and heat detectors installed at the existing apartment houses should be replaced with residential sprinkler heads and smoke detectors for rapid fire suppression. In addition, sprinkler systems should be considered to be installed for excluded floor at apartment houses. Especially, it is necessary to construct remote inspect systems like advanced countries for efficiency of apartment houses safety management.

A Study on Emergency Evacuation Route Planning and USN-Based Induction Activities of Correctional Facilities (교정시설의 비상시 피난경로계획 및 USN기반 대피유도활동에 관한 연구)

  • Park, Joo-Hyung;Park, Jong-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.39-46
    • /
    • 2011
  • In correctional facilities with majority of occupants in custody, the safe evacuation guide without getaway accidents should be very important due to complexity in escape paths. Fire causes are various in correctional facilities, for example, arson fire is a major cause in mental treatment facilities, however, old facilities or carelessness of flammable materials consist of fire causes in jail facilities. Both types of correctional facilities are the same in terms of many casualties from the fire cases. The thesis focus on escape paths and evacuation guide plans on the basis of analysis on fire cases and structural vulnerability, and then an electronic unlocking system is concededly installed for safe evacuation of occupants in custody without getaway accidents. Especially, the effect of the electronic unlocking system is going to be analyzed on the basis of RSET (required safe egress time) in order to realize for the occupants to evacuate safely to the front yard in case of emergency. In conclusion, if electronic security allowed system with USN (Ubiquitous Sensor Networks) technology should be installed in multi-storey correctional buildings, it is proposed that the occupants in custody might be a guided safely without getaway trials.

Fire Alarm Sound Transmission in Apartment Units (공동주택에서의 화재경보음 전달)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.67-75
    • /
    • 2018
  • To reduce the number of casualties in the case of fire, an alarm sound needs to be delivered to the people who remain in the apartment unit. On the other hand, it was reported that the fire alarm sound generated in the elevator hall was not delivered sufficiently to the people staying in the apartment units. In this study, the background noise level and noise level generated in an apartment unit were measured during the day and night time. In addition, the transmission of the fire alarm sound into the each room of apartment units was simulated and compared with the background noise level. The fire alarm sound generated in the elevator halls was reduced by the fire door and doors, and was not transmitted sufficiently into the internal spaces of the apartment units. Starting evacuation action was difficult after hearing the fire alarm sound generated outside the apartment units. To improve the transmission of an alarm sound to the inner spaces of apartment units, an acoustic simulation was carried out for cases where the alarm sound generator was installed on a wall-pad in the living room and the alarm sound generator was installed on the ceiling of each rooms in apartment units. Background noise of + 15 dB and 75 dB (A) were satisfied when alarm sound generator was installed on the ceiling of each room.

Development of a Framework of Emergency Action Plan for Domestic Water Front Critical Infrastructure (국내 주요 수변시설물 EAP 프레임워크 개발)

  • Park, Su-Yeul;Choi, Soo-Young;Oh, Eun-Ho;Kim, Jin-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.125-134
    • /
    • 2017
  • Unusual precipitation caused by typhoons and severe rain stormscan threaten human life and property. Thus, various organizations prepare emergency action plans (EAPs) to provide proper guidelines for operators, experts, and emergency response personnel to protect and enhance critical infrastructure. For example, FEMA and DHS have various types of EAPs for dams, levees, and other structures to protect people and property. FEMA defines EAPs as official documents to decrease the damage and impact in emergency situations and to reduce casualties. These documents should consider all possible situations in an emergency and can reduce problems in facility management. This study analyzes EAPs for infrastructure from the USA, Japan, and Korea in order to suggest an ideal EAP framework. EAPcontent can include how to guide experts and operators in disaster stages (mitigation, preparedness, response, and recovery), how to operate emergency equipment, and how to protect critical infrastructure and life. The suggested EAP framework performed very well in a test location. It can therefore be used for infrastructure organizations in Korea and to inform of the appropriate processes and methods for risk reduction in flood disasters.

A Study on the Diffusion of Emergency Situation Information in Association with Beacon Positioning Technology and Administrative Address (Beacon 위치측위 기술과 행정주소를 연계한 재난재해 상황 전파 연구)

  • Mo, Eunsu;Lee, Jeakwang
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.9
    • /
    • pp.211-216
    • /
    • 2016
  • Worldwide casualties caused by earthquakes, floods, fire or other disaster has been increasing. So many researchers are being actively done technical studies to ensure golden-time. In this paper if a disaster occurs, use the IoT technologies in order to secure golden-time and transmits the message after to find the user of the accident area first. When the previous job is finished, gradually finds a user of the surrounding area and transmits the message. For national emergency information, OPEN API of Korea Meteorological Administration was used. To collect detailed information on a relevant area in real time, this study established the system that connects and integrates Crowd Sensing technology with BLE (Bluetooth Low Energy) Beacon technology. Up to now, the CBS based on base station has been applied. However, this study designed and mapped DB in the integration of Beacon based user positioning and national administrative address system in order to estimate local users. In this experiment, the accuracy and speed of information dif6fusion algorithm were measured with a rise in the number of users. The experiments were conducted in a manner that increases the number of users by one thousand and was measured the accuracy and speed of the message spread transfer algorithm. Finally, became operational in less than one second in 20,000 users, it was confirmed that the notification message is sent.

The Realization on GAS Sensor Module for Inteligent Wireless Communication (지능형 무선통신용 가스 센서 모듈 구현)

  • Kim, Hyo-Chan;Weon, Young-Su;Cho, Hyung-Rae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.6
    • /
    • pp.123-132
    • /
    • 2012
  • Gas sensors has been used very differently that depending on following purposes; Automotive (exhaust gas, fuel mixture gas, oxygen, particulates), agriculture / food industry (fresh, stored, CO2, humidity, NH3, nitrogen oxide gas, organic gas, toxic gas emitted from pesticides and insecticides), industrial / medical (chemical gas, hydrogen, oxygen and toxic gases), military (chemical weapon), environmental measurements (CO and other air pollution consisting of sulfur and nitrogen gas), residential (LNG, LPG, butane, indoor air, humidity). The types of industrial toxic substances are known about 700 species and many of these exist in gaseous form under normal conditions. he multi-gas detection sensors will be developed for casualties that detect the most important and find easy three kinds of gases in marine plant; carbon dioxide(CO2), carbon(CO), ammonia(NH3). Package block consists of gas sensing device minor ingredient, rf front end, zigbee chip. Develope interworking technology between the sensor and zigbee chip inside a package. Conduct a performance test through test jig about prototype zigbee sensor module with rf output power and unwanted emission test. This research task available early address when poisonous gas leaked from large industrial site and contribution for workers' safety at the enclosed space.

Electrical and Fire Prevention Measures through Improvement of Indoor Wiring, Outlets and Plugs (옥내배선, 콘센트 및 플러그 개선을 통한 전기화재 예방대책)

  • Jeung, Sueng Hyo;An, Hui-Seok;Lee, Yong-Su;Kim, Chang-Eun
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.1 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • It is reported that about 20 % of all fires in Korea are caused by the electric equipment and installations. In complex and large-scale buildings, the sizes of electric fires are becoming larger as property damage and casualties increase. Among the causes of various electric fires, fire by short circuit accounts for about 71.5% of overall fires, and in the classification by electric equipment and installation, fire caused by wiring and wiring equipment accounts for approximately 38.3% of overall fires. The purpose of this study is to propose methods to prevent electric fires due to short circuit by improving indoor wiring currently in use and to find the fundamental measures to prevent wiring equipment caused fires by improving the socket and plug which are commonly used in wiring equipment. It is expected that the electric fire prevention measures presented through this study can be used as a measure to protect many people and properties by eliminating the root cause of electric fire.