• Title/Summary/Keyword: Cassette

Search Result 354, Processing Time 0.033 seconds

Design and Performance Evaluation of the Precision Pressure Control System for the High Vacuum Transport Module (고진공 운송계에서의 정밀 압력제어장치의 설게 및 성능시험)

  • Jang, W.I.;Jang, K.H.;Lee, J.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.92-98
    • /
    • 1995
  • In the cluster tool, it is necessary to precisely control the vacuum pressure for the wafer transportation between transport module and cassette or process modules with the range of 1*10$^{-4}$ to 5*10$^{-5}$ torr. So we have designed the pressure control system for the transport module of the cluster tool and have evaluated its performance. Digital PID is utilized with the weighted sum of both three previous errors and one current error. The feedback signal is put into the nitrogen mass flow controller using the transport module controller. This pressure control system can prevent the transport module from the particle generation and backstreaming of hazardous process gases of the process chamber.

  • PDF

고진동 운송계에서의 정밀 압력제어 장치의 설계 및 성능실험

  • 장원익;장기호;정기로;이종현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.237-242
    • /
    • 1993
  • In the cluster tool, it is necessary to precisely control the vacuum pressure for the wafer transportation between transport module and cassette or process with the range of 10 $^{-4}$ to 5*10 $^{-5}$ torr. So we have designed the pressure control system for the transport module of the cluster tool and have evaluated its performance. Digital PID is utilized with the weighted sum of both three previous errors and one current error. The feedback signal is put into the nitrgen mass flow controller using the transport module controller. This pressure control system can prevent the transport module from the particle generation and backstreaming of hazardous process gases of the process chamber.

  • PDF

Integration and Control Technology of GaAs Bonding System using DeviceNet (DeviceNet 을 채용한 GaAs 본딩 시스템의 통합 제어기술)

  • 송준엽;이승우;임선종;김원경;배영걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1376-1379
    • /
    • 2004
  • This study is designed integration and control system of GaAs bonding system consisted of multi-processing using DeviceNet and GEM-Protocol. Developing bonding system is composed of resin coating, pre-baking pre-aligner, bonding, material handler(flip robot), and wafer cassette, etc. This system has process-fluent of each a process and share information using GEM-protocol. This study devised virtual bonding simulator to control and to monitor bonding system efficiently. Also we can verify optimizing of system previously through a virtual bonding simulator.

  • PDF

Reliability Analysis of Degradation Data Based on Accelerated Model -With Photointerrupter Used in Home VCR(Video Cassette Recorder)- (가속 모델에 기초한 열화 데이터의 신뢰성 해석 -가정용 영상 재생기에 사용되는 광센서를 중심으로-)

  • Kwon, Soo-Ho;Huh, Yang-Hyun;Lim, Tae-Jin
    • IE interfaces
    • /
    • v.12 no.3
    • /
    • pp.448-457
    • /
    • 1999
  • Accelerated degradation is concerned with models and data analyses for degradation of product performance over time at overstress and design conditions. Although there have been numerous studies with accelerated degradation theory in reliability, very few actually apply to parametric statistical analyses. This paper shows how to analyze degradation data, provides tests for how well the assumptions hold. Reel sensors, a sort of photointerrupters in home VCR, hive been tested, and least-square analyses are used to illustrate our approach. Tests for linearity of the performance-time relationship, dependence of the lognormal distribution, and the standard deviation on time are performed. The mean life of tested sensors is assessed at about 414,000 hours, and the Arrhenius activation energy of this reaction is concluded to be 0.39 eV as results.

  • PDF

Development of Clinical Chemistry Analyzer with the Dry Reagent Strip(I) (건습시약 스트립을 사용한 임상화학분석장치 개발[I])

  • Yoo, Dong-Joo;Jung, Tae-Hwa;Min, Hong-Kee;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.299-306
    • /
    • 1992
  • For quantitative measurement of reflected light from a clinical diagnostic scrip, a prototype of reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate re(leclance parameters. The strop was illuminated at $45^{\circ}C$ through optical fiber and the intensity of reflected light was determined at rectangulat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/dl about glucose, a saturation state of absorbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

The Design of the U-Shaped Assembly Line to Replace Conveyor Systems (컨베이어 라인 변경시 U - 라인 설계의 효율적 방안 - K전자 사례를 중심으로 -)

  • Park, Seung-Hun
    • IE interfaces
    • /
    • v.16 no.2
    • /
    • pp.240-247
    • /
    • 2003
  • Generally, the assembly system relied on conveyor lines is efficient for mass production. But it is not efficient when the product types are often varying and their lot sizes are small. Especially, it is much inefficient for the assembly lines for the electronic products whose types are varying very often. This paper suggests the design of U-shaped assembly lines to replace the existing conveyor systems. The assembly line for the mini-cassette production is dealt with as a case study. The proposed procedure was successfully applied for the design of U-shaped lines. The developed method resulted in the improvement of the productivity such as the decrease of the man power and the cycle time, and the increase of the line utility.

Development of the Process Planning Program for a Multi-functional Surface Mounting Device (다기능 표면실장기의 공정계획 프로그램 개발)

  • Sohn, Jin-Hyeon;Yu, Sung-Yeol;Kang, Jang-Ha;Park, Sung-Soo;Oh, Byung-Jun;Seong, Pil-Young
    • IE interfaces
    • /
    • v.10 no.1
    • /
    • pp.155-167
    • /
    • 1997
  • The purpose of this study is to develop the program for efficient operation of a multi-functional surface mounting device(SMD) which mount various components on a printed circuit board(PCB). These components are provided by diverse types of feeders such as cassette, stick and tray feeders. The SMD has one or two heads. In the SMD, the positions of PCB and feeders and fixed, and the head moves to pick up a component from a feeder and to mount it on the PCB. The number of lanes occupied by each feeder and the nozzle used for each component can be different. We develop an off-line program to minimize the cycle-time of the SMD by studying the optimal assignment of feeders and the optimal mounting sequence of components. Graphical User Interface(GUI) is also developed. Additionally, we consider the line balancing problem which appears when two SMDs are used sequentially.

  • PDF

Simultaneous and Sequential Integration by Cre/loxP Site-Specific Recombination in Saccharomyces cerevisiae

  • Choi, Ho-Jung;Kim, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.5
    • /
    • pp.826-830
    • /
    • 2018
  • A Cre/loxP-${\delta}$-integration system was developed to allow sequential and simultaneous integration of a multiple gene expression cassette in Saccharomyces cerevisiae. To allow repeated integrations, the reusable Candida glabrata MARKER (CgMARKER) carrying loxP sequences was used, and the integrated CgMARKER was efficiently removed by inducing Cre recombinase. The XYLP and XYLB genes encoding endoxylanase and ${\beta}$-xylosidase, respectively, were used as model genes for xylan metabolism in this system, and the copy number of these genes was increased to 15.8 and 16.9 copies/cell, respectively, by repeated integration. This integration system is a promising approach for the easy construction of yeast strains with enhanced metabolic pathways through multicopy gene expression.

The Study of Possibility of Finding a Reagent for Cancer Diagnosis by Urine NMR Measurement

  • Kim, Yong-J.
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1986
  • For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

A Study on Clinical Chemistry Analyzer Development by Using the Reflected Visible Light (가시 반사광을 이용한 임상화학 분석장치 개발의 기초연구)

  • Yoo, Dong-Joo;Jung, Tea-Hwa;Min, Hong-Kee;Huh, Woong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.144-147
    • /
    • 1992
  • In this paper, we study about reflectance photometer for measuring teflectance changes on reagent strip material after applying of a liguid sample. To obtain more accurate reflectance parameter, the strip loader and cassette is designed. The system is designed to work with IBM personal computer. As the experimental results, reflectance level measured of korean standard color paper and shows a exponentially proportion to brightness of paper. A diagnostic strip for total protein is applied to our system and shows a good correlation in a physically protein concentration range.(up to 500 mg/dl).

  • PDF