• Title/Summary/Keyword: Cascading

Search Result 170, Processing Time 0.027 seconds

Design of the Expanded Interrupt Controller using VHDL (VHDL을 이용한 확장 인터럽트 제어기의 설계)

  • 박성수;박승엽
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.3
    • /
    • pp.558-567
    • /
    • 2003
  • Most digital signal processors provide 4 external interrupt input channels. But these are not sufficient for external interrupts of motor controls. Customized programmable interrupt controller, 8259, has 8 interrupt channels. Therefore, in the case of more external interrupt channels are needed, designers must expand by cascading the 8259. And this, 8259 device, have some inconvenience of interfacing the microprocessor in motor controls. In this paper, the expanded interrupt controller with 14 sufficient interrupt input channels for motor controls is designed using VHDL on the purpose of interfacing the microprocessor to the interrupt controller more compatibly and increasing the device utilization of FPGA/CPLD designed another peripherals. The interrupt controller model and each function blocks is proposed and illustrated. Simulation result are presented to estimate the designed interrupt controller.

Analysis of the Internal Electrical Characteristics of Electronic Power Transformers

  • Yi, Yang;Mao, Cheng-Xiong;Wang, Dan;Lu, Ji-Ming
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.746-756
    • /
    • 2013
  • The modularized subunit of an electronic power transformer (EPT) is a series connection of two H-bridge voltage-source converters and a DC-DC converter with a high-frequency isolation transformer (HFIT). On the basis of cascading and paralleling the modularized subunits, EPT can be used in high-voltage and large-current applications in the power system. This paper discusses the steady state analysis of the modularized subunit of EPT. Theoretical analysis considers the influences of the two H-bridge voltage-source converters on the two sides of the DC-DC converter. We deduce the formulas of the theoretical calculation on the internal electrical characteristics of EPT (e.g., the voltages of the DC-bus capacitor and the primary side peak current of the HFIT). This paper provides guidance on the design and selection of EPT key elements (e.g., the DC-bus capacitors and HFIT). Experimental results are obtained from a single subunit of a laboratory model rated at 962 V, 15 kVA. All calculations, simulations, and experiments confirm the theoretical analysis of the subunit of EPT.

Error propagation in 2-D self-calibration algorithm (2차원 자가 보정 알고리즘에서의 불확도 전파)

  • 유승봉;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.434-437
    • /
    • 2003
  • Evaluation or the patterning accuracy of e-beam lithography machines requires a high precision inspection system that is capable of measuring the true xy-locations of fiducial marks generated by the e-beam machine under test. Fiducial marks are fabricated on a single photo mask over the entire working area in the form of equally spaced two-dimensional grids. In performing the evaluation, the principles of self-calibration enable to determine the deviations of fiducial marks from their nominal xy-locations precisely, not being affected by the motion errors of the inspection system itself. It is. however, the fact that only repeatable motion errors can be eliminated, while random motion errors encountered in probing the locations of fiducial marks are not removed. Even worse, a random error occurring from the measurement of a single mark propagates and affects in determining locations of other marks, which phenomenon in fact limits the ultimate calibration accuracy of e-beam machines. In this paper, we describe an uncertainty analysis that has been made to investigate how random errors affect the final result of self-calibration of e-beam machines when one uses an optical inspection system equipped with high-resolution microscope objectives and a precision xy-stages. The guide of uncertainty analysis recommended by the International Organization for Standardization is faithfully followed along with necessary sensitivity analysis. The uncertainty analysis reveals that among the dominant components of the patterning accuracy of e-beam lithography, the rotationally symmetrical component is most significantly affected by random errors, whose propagation becomes more severe in a cascading manner as the number of fiducial marks increases

  • PDF

A Study on the Spatio-Temporal Processing Structure in Adaptive SLC (적응 Sidelobe Canceller에서의 Spatio-temporal 처리구조에 관한 연구)

  • 김은정;문성빈;이병섭;김진호;홍동희
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.3
    • /
    • pp.329-336
    • /
    • 2000
  • An important problem associated with adaptive sidelobe canceller(SLC) systems is that their performance deteriorates with an increase in jammers arriving from different directions. Generally the number of jammers which can be effectively cancelled is limited by the number of the auxiliary elements in a SLC system. But the single-auxiliary-element with tapped delay line adaptive filter can effectively cancel multiple jammers. Therefore this paper proposed the spatio-temporal processing structure cascading adaptive array and tapped delay line adaptive filter and showed that this could obtain more rapid convergence rate and an increase of DOF without increasing the number of element.

  • PDF

Multi-level UnderVoltage Load Shedding Scheme Considering Rate of Change of Voltage for Voltage Stability (전압 변동률을 고려한 수도권 전압 안정화 다단계 부하차단 적용 방안)

  • Lee, Yun-Hwan;Kim, Tae-Gyun;Kim, Ji-Hun;Lee, Byong-Jun;Kang, Bu-Il;Cho, Jong-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2335-2341
    • /
    • 2009
  • High technique growth of modem times and high industrial facility in consequence of buildings demand for electric power of an extensive scale with stability supply and maintenance of high quality. But, power system always have risk of network contingency. When power system break out disturbance, it circumstantially happen like uncontrolled loss of load developing from of cascading. Severely which would be raised wide area blackout, plan to prevent, which make stability through a little of load shedding and multi-level UnderVoltageLoadShdding should work. This paper presents target, sensitivity of bus voltage have choose appropriating load shedding location and load shedding decision making logic with considering rate of change of voltage have studied multi-level under voltage load shedding scheme. Calculation of rate of change of voltage applied method of least square. As a result, we are studied an dynamic analysis of 2008 summer peak data. We have been known that network analysis is a little development and developing UnderVoltageLoadShedding scheme.

An Algorithm of Predicting the Zone 3 Trip Time of Distance Relay by using PMU Data when Power Systems Face Cascaded Event on Transmission System (송전 계통의 광역정전 징후 시 PMU 취득 데이터를 이용한 거리계전기 Zone3 동작시간 예측 알고리증)

  • Kim, Jin-Hwan;Lim, Il-Hyung;Lee, Seung-Jae;Choi, Myeon-Song;Kim, Tae-Wan;Lim, Seong-Il;Kim, Sang-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2303-2310
    • /
    • 2009
  • Defense systems are needed to prevent catastrophic failures of a power grid due to cascaded events. Cascaded events can be attributed to improper operations of protective relays. Especially, it is the most dangerous problem that trips of backup relays by overload. In this paper, a new algorithm of predicting Zone 3 acting time of distance relay is proposed using the real time synchronized data from PMUs on the transmission system when the power system is danger. In the proposed, some part of the power system are outage when some unexpected fault in the power system, the algorithm will monitor the impedance locus of distance relay. At this time, if there is a big change of Impedance locus, the algorithm will calculate the Zone 3 acting time of the distance relay by the over load. In the case studies, the estimation and simulation network have been testified and analysed in Matlab Simulink.

A Study on the Application of Under Voltage Load Shedding Scheme in Line Contingency considering Motor Load (모터부하를 고려한 상정사고 발생 시 저전압 부하차단 적용 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • Failure of high-voltage transmission line, which is responsible for large-scale power transmission, can be reason for system voltage instability. There are many methods to prevent voltage instability like adjustment of equipment, the generator voltage setting, and load shedding. Among them, the load shedding, have a problem of economic loss and cascading effect to power system. Therefore, the execution of load shedding, amount and timing is very important. Conventionally, the load shedding setting is decided by the preformed simulation. Now, it is possible to monitor the power system in real time by the appearance of PMU(Phasor Measurement Unit). By this reason, some of research is performed about decentralized load shedding. The characteristics of the load can impact to amount and timing of decentralized load shedding. Especially, it is necessary to consider the influence of the induction motor loads. This paper review recent topic about under voltage load shedding and compare with decentralized load shedding scheme with conventional load shedding scheme. And simulations show the effectiveness of proposed method in resolving the delayed voltage recovery in the Korean Power System.

Cascade Perimeter Defence Model in Multiple VPN Environment (다중 VPN 환경에서의 분산 Perimeter defence 모델에 관한 연구)

  • Lim, Hyung-J.;Kim, Tae-Kyung;Chung, Tai-M.
    • The KIPS Transactions:PartC
    • /
    • v.11C no.1
    • /
    • pp.81-88
    • /
    • 2004
  • This paper analyzed the proper methods to solve the security problems of establishing trust zone which is changed by security policy in large scale networks containing multiple VPNs. Therefore, we surveyed the vulnerability of VPN technologies, it analyzed various models suitable for trust zone. By simulations of various models, we Propose the cascade perimeter defence policy model having the neit as such an efficient transit cost and the strictly isolation for trust tone. This model can protect the trust zone from the public network by dividing the trust Tone according to each VPN group and it shows the better transit performance by cascading the position of perimeter defence policy.

A Modified Switched-Diode Topology for Cascaded Multilevel Inverters

  • Karasani, Raghavendra Reddy;Borghate, Vijay B.;Meshram, Prafullachandra M.;Suryawanshi, H.M.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1706-1715
    • /
    • 2016
  • In this paper, a single phase modified switched-diode topology for both symmetrical and asymmetrical cascaded multilevel inverters is presented. It consists of a Modified Switched-Diode Unit (MSDU) and a Twin Source Two Switch Unit (TSTSU) to produce distinct positive voltage levels according to the operating modes. An additional H-bridge synthesizes a voltage waveform, where the voltage levels of either polarity have less Total Harmonic Distortion (THD). Higher-level inverters can be built by cascading MSDUs. A comparative analysis is done with other topologies. The proposed topology results in reductions in the number of power switches, losses, installation area, voltage stress and converter cost. The Nearest Level Control (NLC) technique is employed to generate the gating signals for the power switches. To verify the performance of the proposed structure, simulation results are carried out by a PSIM under both steady state and dynamic conditions. Experimental results are presented to validate the simulation results.

The Comparative Study on the Fish Community in Lake Chungpyung and Lake Paldang (청평호 및 팔당호 어류군집 비교 연구)

  • Park, Hae-Kyung;Lee, Jangho;Yun, Seuk-Hwan;Choi, Myung-Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.7-18
    • /
    • 2013
  • We compared the structure of fish community and condition of major fish species in Lake Chungpyung and Lake Paldang, which are relatively shallow, meso-eutrophic, cascading dam reservoirs on the North Han River. Two lakes have wide littoral zone in the lakeside providing similarly good habitat for fishes, whereas fishery and water recreational activities such as motorboating, water skiing are allowed in Lake Chungpyung but are prohibited in Lake Paldang. The average lengths of large size fishes in Lake Chungpyung are shorter than those of same species in Lake Paldang, resulting in the slight distortion of generation distribution of those species in Lake Chungpyung, possibly owing to the active fishery such as fixed shore net fishing, gill net fishing and angling. Meanwhile the condition of fishes represented by the length-weight relationship of fish species did not show the significant differences between two lakes and showed normal condition. To evaluate the impact of physical disturbance such as loud noise and turbulent wave from water recreational activities to fishes precisely, further studies including physiological responses to stress an spawing activity should be needed.