고온측 냉매에 따른 이원 냉동시스템의 성능 분석 (Performance Analysis of Cascade Refrigeration System with Respect to Refrigerants Appling to High Temperature Cycle)

  • 윤정인;전민주;손창효
    • 동력기계공학회지
    • /
    • 제21권3호
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents the Coefficient of performance(COP) and mass flow ratio of cascade refrigeration system with respect to refrigerants appling to high temperature cycle. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporating temperature, condensing temperature and internal heat exchanger effectiveness in high temperature cycle. The result of this study is as follows : The COP of cascade system increases with increasing degree of superheating and subcooling, compressor efficiency and internal heat exchanger effectiveness except increasing condensing temperature. The mass flow ratio of low and high temperature cycle increases with increasing evaporating temperature and condensing temperature, but decreases with increasing internal heat exchanger effectiveness, degree of superheating and subcooling. Also, the mass flow ratio has no correlation with compressor efficiency at high temperature cycle.

R744-R404A용 캐스케이드 냉동시스템의 엑서지 분석 (Exergy Analysis of R744-R404A Cascade Refrigeration System)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1001-1008
    • /
    • 2011
  • 본 논문은 내부 열교환기를 가지는 R744와 R404A용 캐스케이드 냉동시스템의 운전변수에 대한 최적의 설계를 위해서 냉동장치의 성능과 엑서지를 이론적으로 분석하였다. 본 연구에서 고려된 작동변수로는 과열도와 과냉각도, 내부 열교환기와 압축기 효율, 증발 및 응축온도 등이다. 분석한 결과를 요약하면 다음과 같다. 캐스케이드 증발온도가 증가할수록 R404A용 고온사이클의 COP는 증가하는 반면에, R744용 저온사이클의 COP는 감소한다. 따라서 이러한 이유로 전체 캐스케이드 냉동사이클의 COP는 거의 일정하다. 또한 캐스케이드 증발온도가 증가할수록 R404A용 응축기와 압축기의 엑서지 손실이 가장 큰 것을 알 수 있다. 따라서 R744와 R404A용 캐스케이드 냉동시스템의 COP 향상을 위해서는 R404용 응축기와 압축이의 엑서지 손실을 줄여야만 한다.

해수열원 히트펌프 시스템의 냉난방 운전 특성에 관한 실증 연구 (Experimental Study on the Cooling and Heating Operation Characteristics of a Sea Water Source Heat Pump)

  • 김지영;백영진;나호상;장기창
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.544-549
    • /
    • 2009
  • The purpose of this study is to investigate the field Operation Characteristics of a sea water heat source cascade heat pump system and system applicable to Building. Cascade heat pump system is composed R410A compressor, R134a compressor, EEV, cascade heat exchanger, Plate heat exchanger etc. Building area is $890m^2$ and has five floors above ground. R410A is used for a low-stage working fluid while R134a is for a high-stage. The system could runs at dual mode. One is mode of general R410A refrigeration cycle in summer and the other is cascade cycle. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. The filed test results show that the sea water heat source heat pump system exhibits a COP of about 5.5 in cooling mode along with a heating COP of about 4.0 in 1-stage heating mode. Cascade 2-stage heat pump system is enough to supply $60^{\circ}C$ water and heating COP is about 3.0

  • PDF

R744-R404A 캐스케이드 냉동시스템의 최적 냉매 충전을 위한 질량유량비 분석 (Mass flow rate ratio analysis for optimal refrigerant charge of a R744 and R404A cascade refrigeration system)

  • 오후규;손창효;조환;전민주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.575-581
    • /
    • 2013
  • 본 논문은 R744-R404A 캐스케이드 냉동시스템의 최적 냉매 충전을 위해 과냉도, 과열도, 내부열교환기 효율 등에 대한 영향을 분석한 것이다. 연구에 사용된 캐스케이드 냉동시스템의 고온 사이클에는 R404A, 저온 사이클에는 R744를 적용하였다. 그 주요 결과는 다음과 같다 : 고온 사이클의 과냉도, 과열도, 내부열교환기 효율과 저온 사이클의 증발온도와 압축효율은 크게 할수록 질량유량비가 작게 나타났다. 그리고 캐스케이드 온도차와 고온 사이클의 증발온도, 응축온도와 저온 사이클의 과냉도, 과열도, 내부열교환기 효율은 작을수록 질량유량비가 작게 나타났음을 확인하였다.

운전조건에 따른 가변속 캐스케이드 열펌프의 성능 특성 연구 (Study on the Performance of a Variable Speed Cascade Heat Pump under Various Operating Conditions)

  • 정광무;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권2호
    • /
    • pp.1-7
    • /
    • 2013
  • Most researches done on heat pumps have been on heat pumps for refrigeration, cooling and heating. There is therefore the need for more research on hot water heat pumps, especially for high temperature. Even though the cascade heat pump cycle has a great potential more efficient hot water generation even at low evaporating temperatures, it has been researched least for this purpose. In this study, the heating performance of a variable speed cascade heat pump was investigated by varying operating conditions. For the same heating capacity values, it was found that increasing the low stage compressor speed was more suitable for enhancing the performance of the system to get a higher temperature.

델타시그마 변환기 구조와 Limit Cycle 발생 (Delta-Sigma Modulator Structure and limit Cycle Generation)

  • 현덕환
    • 전자공학회논문지SC
    • /
    • 제43권1호
    • /
    • pp.39-44
    • /
    • 2006
  • 델타시그마 변환기에서 limit cycle 에 의한 패턴 노이즈 문제는 오래 동안 설계자들을 괴롭혀 온 문제이다. 델타시그마 변환기의 동작과 출력은 입력과 초기치에 의해 결정된다. 본 논문은 델타시그마 변환기의 구조에 따른 패턴잡음의 발생정도를 널리 쓰이는 네 가지 모델로 비교 하였다. 델타시그마 변환기 중 적분기형 과 공진기형의 차이와 부궤환 방식에 따른 차이를 비교 하였으며 그 결과는 적분기 형식의 증폭단을 사용하는 델타시그마 변환기가 패턴잡음을 적게 발생시키는 것으로 판명되었다.

LNG 열교환기의 압력강하에 따른 천연가스 액화용 초저온 캐스케이드 냉동사이클 특성 (Characteristics of Cryogenic Cascade Refrigeration Cycle for Liquefaction of Natural Gas with the Pressure Drop of Heat Exchanger)

  • 윤정인;최광환;손창효;곽진우;백승문
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.756-761
    • /
    • 2012
  • 천연가스는 $-160^{\circ}C$까지 냉각 및 액화되어 액화천연가스(LNG)가 되고, 이때 LNG의 체적은 천연 가스의 1/600로 줄어든다. 이로 인해 LNG는 수송시에 이점이 있다. 본 연구에서는 천연가스 액화용 초저온 캐스케이드 냉동사이클의 LNG 열교환기내 냉매와 천연가스의 압력강하가 액화사이클에 미치는 영향을 파악한 후, LNG 열교환기 설계시 압력강하에 대한 기준안을 제시하고자 한다. 이를 위해 HYSYS를 이용하여 초저온 캐스케이드 액화사이클 내 LNG 열교환기의 압력강하에 대해서 시뮬레이션을 수행하였다. 그 결과, 초저온 액화사이클의 압축일량과 성능계수(COP)의 증가로부터, LNG 열교환기 내의 압력강하는 50 kPa정도를 기준 설계 압력강하로 설정할 수 있음을 알 수 있었다.

$NH_3-CO_2$를 사용하는 이원 냉동 시스템의 성능 분석 (Performance Analysis of an Ammonia(R717) and Carbon Dioxide(R744) Two-Stage Cascade Refrigeration System)

  • 손창효
    • 한국가스학회지
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2010
  • 본 논문은 암모니아-이산화탄소용 이원 냉동시스템의 작동변수에 대한 최적의 설계자료를 제공하고자 이원 냉동시스템의 사이클 성능을 분석하였다. 작동변수로는 암모니아용 고온사이클과 이산화탄소용 저온사이클내의 과냉각도와 과열도, 압축기효율, 응축과 증발온도이다. 이에 대한 주요결과를 요약하면 다음과 같다. 이원 냉동사이클의 과냉도가 증가할수록 COP는 증가하는 반면 과열도가 증가할수록 COP는 감소하는 것을 알 수 있다. 이원 냉동사이클의 응축온도가 증가할수록 이원 냉동사이클의 COP는 증가하는 반면 증발온도가 증가할수록 COP가 감소함을 알 수 있다. 또한, 이원 냉동사이클의 압축효율이 증가할수록 COP가 증가한다. 따라서, 과열도, 과냉각도, 압축효율, 증발온도, 응축온도 등의 인자들이 R717과 R744용 이원 냉동사이클의 COP에 영향을 미친다.

R718-R744용 캐스케이드 냉동시스템의 최대 성능 예측 (Prediction on Maximum Performance of Cascade Refrigeration System Using R717 and R744)

  • 노건상;손창효
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2565-2571
    • /
    • 2009
  • 본 논문은 시스템의 운전조건하에서 R717-R747용 이원냉동 사이클의 성능 분석에 대한 기초 설계자료를 제공하는 것이다. 본 논문에서 고려한 운전변수는 암모니아 고온사이클과 이산화탄소 저온사이클의 과냉각도, 과열도, 응축과 증발온도이다. 이원 냉동사이클의 성적계수는 과열도가 증가할수록 증가하는 반면, 과냉각도가 증가할수록 감소한다. 그리고, 이원 냉동사이클의 성적계수는 응축온도와 함께 증가하지만, 증발온도와는 반대로 감소한다. 따라서, 과열도, 과냉도, 응축과 증발온도는 본 시스템의 성적계수에 영향을 미치는 것을 알 수 있었고, 최대 성능계수와 최적의 증발온도에 대한 수학 방정식을 개발하기 위해 이러한 변수들을 포함시켜 다중 회귀분석을 통해 제안하였다.

LNG FPSO에 적용가능한 신액화 사이클의 효율 및 엑서지 분석 (Efficiency and Exergy Analysis of New Liquefaction Cycles Applied for LNG FPSO)

  • 윤정인;손창효;백승문;곽진우;심규진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.574-579
    • /
    • 2012
  • 본 논문에서는 $CO_2-C_2H_6-N_2$$CO_2-N_2$를 각각 적용한 캐스케이드 액화사이클을 새롭게 제안하고, HYSYS를 이용하여 이에 대한 성능 및 엑서지를 분석한 후, 이 사이클이 LNG-FPSO선에 적용가능여부를 확인하였다. 그 분석 결과로부터, 효율적인 측면에서는 $CO_2-C_2H_6-N_2$ 액화사이클이 우수하였고, 엑서지 손실측면에서는 장치 수가 적은 $CO_2-N_2$ 액화사이클이 오히려 높게 나왔다. 그리고 $CO_2-N_2$ 냉매용액화사이클은 기존의 $C_3H_8-C_2H_4-C_1H_4$ 보다 낮은 효율과 높은 압축일량을 보였다. 하지만, $N_2$ 사이클의 효율이 더 개선된다면 액화사이클의 구조가 간단하기 때문에 LNG-FPSO용 액화사이클로서 적합할 것으로 생각된다.