• Title/Summary/Keyword: Carbon-monoxide

검색결과 1,008건 처리시간 0.033초

Study on Fire Simulation in College Dormitories Based on Pyrosim

  • Zechen Zhang;Hasung Kong
    • International journal of advanced smart convergence
    • /
    • 제13권3호
    • /
    • pp.321-327
    • /
    • 2024
  • In recent years, the frequency of fires in college dormitories has been increasing, primarily due to outdated electrical wiring and improper use of electrical appliances. Given the high population density in such buildings, fires can cause significant damage to life and property. To better understand the dynamics of dormitory fires, this study uses Pyrosim fire simulation software to model fire scenarios in a six-story male dormitory. The study focuses on analyzing key factors such as heat release rates, smoke spread, temperature changes, and carbon monoxide concentrations during a fire. Simulation results indicate that smoke spreads rapidly after a fire breaks out, significantly reducing visibility and hindering evacuation efforts. Simultaneously, temperatures near the fire source rise quickly, exceeding safe levels, and carbon monoxide concentrations reach dangerous thresholds in a short time, greatly increasing the risk of poisoning. Based on these findings, the study proposes several recommendations to improve fire prevention in dormitories, including installing smoke barriers, improving evacuation routes, adding mechanical smoke extraction systems, and enhancing students' fire safety awareness and skills through regular training. These measures are crucial for reducing fire risks and enhancing fire safety in college dormitories.

A Study on the Measurement and Investigation of Air Quality in a University Library (대학도서관 실내 공기질 측정 및 조사 연구)

  • Lee, Jae-Won
    • Journal of Korean Library and Information Science Society
    • /
    • 제50권4호
    • /
    • pp.635-658
    • /
    • 2019
  • In this study, the harmful factors measured in S university's central library were divided into ① air harmful substance ② biological harmful factors ③ carbon monoxide, carbon dioxide, and nitrogen dioxide concentration, measured and analyzed compared to the relevant criteria. The analysis showed that the harmful substances in the air - fine dust, asbestos, volatile organic compounds and formaldehyde - were all lower than the relevant standards, and that biological harmful factors such as fungi in the air, gramophageal bacteria, and endotoxin were also found to have no particular problems. The concentration of carbon monoxide, carbon dioxide, and nitrogen dioxide in the air was also maintained without any unusual factors compared to the concentration in the ordinary atmosphere. However, the library is a multi-use facility that needs regular cleaning and ventilation to manage the environment.

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • 제26권3호
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

A Study on the Indoor Air Pollution in the Classrooms of Primary, Middle and High Schools in Seoul and Gyeonggi-Do (서울.경기지역 초.중.고등학교 교실의 실내공기오염에 관한 연구)

  • Kim, Yoon-Shin;Lee, Cheol-Min;Moon, Jeong-Suk;Kim, Sang-Uk
    • Journal of the Korean Society of School Health
    • /
    • 제16권1호
    • /
    • pp.81-90
    • /
    • 2003
  • This study was conducted to contribute to the basic data for decisions on environment policy improvement in health promotion for students in elementary, middle and high schools. This study was carried out to investigate the extent of indoor air pollution in elementary, middle and high schools in residential, traffic congestional and industrial areas. The concentrations of major indoor air pollutants(carbon monoxide, carbon dioxide, respiratory particulate, radon) and thermocircumstance (temperature, relative humidity, intensity of illumination) indices were observed from June to August 2000. As results of the survey, the mean values of thermocircumstance in school were $26.94{\pm}1.15^{\circ}C$ of temperature, $68.88{\pm}5.31%$ of humidity and $268.26{\pm}164.60$ Lux of intensity of illumination. The mean concentrations of carbon monoxide, carbon dioxide, respiratory particulate were $8.36{\pm}0.29\;ppm$, $547.66{\pm}175.58\;ppm$, $36.23{\pm}48.39\;{\mu}g/m3$, respectively. These values were lower than those of the indoor environmental standard on the first clause of Article 45 of public utilization service notified public hygiene of the Ministry of Health and Social Affairs. The mean concentration of radon was $20.07{\pm}17.95\;Bq/m3$. Which was below the U.S. EPA radon action level.

A Simulation Study on the Synthesis of Syngas from the Reforming Reaction of Biogas (바이오가스 개질 반응으로부터 합성가스 제조를 위한 반응 모사 연구)

  • HAN, DANBEE;BAEK, YOUNGSOON
    • Journal of Hydrogen and New Energy
    • /
    • 제29권1호
    • /
    • pp.1-10
    • /
    • 2018
  • The amount of biogas increases as the amount of organic waste increases. Recently, biogas from organic waste have been made much efforts to utilize as a energy. In particular, the concentration of $CH_4$ and $CO_2$ generated from sewage sludge and livestock manure treatment are 60-70% and 30-35%, and $CH_4$ and $CO_2$ generated from food wastes are 60-80% and 20-40%. In case of landfill gas, $CH_4$ and $CO_2$ have a concentration of 40-60% and 40-60% respectively. Therefore, in order to use the biogas more widely, it is necessary to convert the biogas to methanol, LNG or DME. In this study, experiments were conducted to produce hydrogen and carbon monoxide through various biogas reforming reactions on $Ni/Ce-ZrO_2/Al2O3$ catalysts. The experiment of synthetic gas synthesis was carried out on a wide concentrations of methane and carbon dioxide, which were the major constituents of biogas from various organic wastes. The effect of $(O_2+CO_2)/CH_4$ (=R') on the yields of hydrogen and carbon monoxide, the conversion rate of methane and carbon dioxide was investigated. Also simulation for syngas synthesis on the $CO_2$ reforming of $CH_4$ was computed by employing total Gibbs free energy minimization method using PRO/II simulator, and compared with the experimental results on wet and dry reforming reaction of biogas.

Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating (가스난방용 적외선 히터의 연소배기가스 특성해석)

  • Kim Young-Gyu;Kwon Jeong-Rock;Kim Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • 제2권1호
    • /
    • pp.66-73
    • /
    • 1998
  • This paper deals with the combustion characteristics of flue gas in infared mobile heaters. The experimental work has been performed to obtain the concentration levels and combustion characteristics of flue gas with varying chamber size and room temperature. The experimental results showed that oxygen depletion sensor device was operated at the oxygen concentration level of $18.3\%$ for all the chamber size. The combustion characteristics of oxygen and carbon dioxide show a linearity After 10 minutes the combustion property of carbon monoxide occurs at random without a level of oxygen and carbon dioxide in closed space of the heater. In these results, it is very important to prevent incomplete combustion through a sufficient ventilation, and accident prevention with a reduction of the oxygen and diffusion of toxic carbon monoxide.

  • PDF

Development and validation of a portable gas chromatograph method for quantitative determination of oxygen and toxic gas impurities in medical oxygen using planar microchromatographic columns and detectors

  • Ekaterina V. Galeeva;Roman R. Galeev;Prachi Sharma;Alexander l. Khokhlov;Dmitry V. Somov;Dmitry A. Semanov;Ilshat R. Aryslanov;Natalia А. Lezhnina;Vladimir Platonov;Nishant Tripathi
    • Analytical Science and Technology
    • /
    • 제37권5호
    • /
    • pp.261-270
    • /
    • 2024
  • This study examines portable Gas Chromatography (GC) for the quantitative analysis of oxygen and impurities, focusing on the development and validation of a method to determine oxygen, carbon monoxide, carbon dioxide, methane, and nitrogen in medical compressed oxygen gas. The goal is to ensure the quality of medicalgrade oxygen. The method's validation assessed its metrological characteristics, demonstrating specificity through clear chromatographic separation of the target gases and the absence of these peaks in the carrier gas chromatogram. It exhibited linearity within the designated concentration ranges, while precision met permissible standards, with the relative standard deviation for intermediate precision being less than 4% for carbon monoxide (0.00025 - 0.00099 %), less than 3 % for methane (0.0005 - 0.00246%) and carbon dioxide (0.0050 - 0.0150 %), less than 2% for nitrogen (0.1 - 0.7 %), and less than 0.01% for oxygen (99.27 - 99.98%). Overall, the validation results confirm the suitability of this analytical method for the quantitative determination of the aforementioned gases in medical compressed oxygen using portable GC with microchromatographic columns and detectors.

Synthesis of $\beta$-SiC Whiskers by Decomposition-Carbonization of Mullite (물라이트의 환원분해 및 탄화법에 의한 $\beta$-SiC 휘스커의 합성)

  • 김종엽;남원식;최상욱
    • Journal of the Korean Ceramic Society
    • /
    • 제32권10호
    • /
    • pp.1139-1146
    • /
    • 1995
  • $\beta$-SiC whiskers could be formed from a system of mullite-carbon-hydrogen by VLS mechanism at elevated temperatures. It was considered that methane gases were generated from the reaction of hydrogen gases with carbon black, and were reacted with mullite to produce two kinds of gases; silicon suboxide (SiO) and carbon monoxide (CO) of precursors of SiC. With increasing the synthesizing temperature up to 146$0^{\circ}C$, the formation of $\beta$-SiC whisker increased from 0.58 mg/$\textrm{cm}^2$ to 3.98 mg/$\textrm{cm}^2$ on the basis of unit area of carbon block, and the diameters of whiskers had their uniformity due to the reduction in stacking faults.

  • PDF

Influence of Carbon Vacancies on CO Chemisorption on TiC(001): A Theoretical Study

  • Kang, Dae-Bok
    • Journal of the Korean Chemical Society
    • /
    • 제61권1호
    • /
    • pp.7-11
    • /
    • 2017
  • The extended $H{\ddot{u}}ckel$ method is employed to analyze the interaction of carbon monoxide with the TiC(001) surfaces, both perfect and containing carbon vacancies. CO exhibits a similar ${\sigma}$-donation interaction for both $Ti_{25}C_{25}$ and $Ti_{25}C_{23}$ clusters, as deduced from the fact that the populations of the CO $5{\sigma}$ orbital are identical upon adsorption, but it bonds more strongly with the $Ti_{25}C_{23}$ than with the $Ti_{25}C_{25}$ because the metal d electron density in $Ti_{25}C_{23}$ provides ${\pi}$ back-bonding interactions with CO that are absent in $Ti_{25}C_{25}$. This work suggests that a difference in reactivity toward CO of stoichiometric TiC and TiC with carbon defects is connected with the occupancy of $2{\pi}^*$ orbitals that leads to a significant weakening of the C-O bond.

Uniform Field Emission from Carbon Nanotubes Fabricated by CO Disproportionation

  • Lee, Jin-Seung;Suh, Jung-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권12호
    • /
    • pp.1827-1831
    • /
    • 2003
  • Field emission of carbon nanotubes (CNTs) fabricated by disproportionation of CO has been studied. CNTs fabricated on well-ordered Co nanowire arrays formed on the porous anodic aluminum oxide templates were well graphitized, uniform in diameter and aligned vertically with respect to the plane of the template, and showed a good field emission property. Very uniform emissions were observed from the CNTs fabricated at relatively low temperature, $500-600^{\circ}C$. Low fabrication temperature such as $500^{\circ}C$ could make it possible to fabricate CNTs on soda lime glass, a low-cost substrate, for display panel.