• Title/Summary/Keyword: Carbon Concentration

Search Result 3,791, Processing Time 0.037 seconds

Breakthrough behaviour of NBC canister against carbon tetrachloride: a simulant for chemical warfare agents

  • Srivastava, Avanish Kumar;Shah, D.;Mahato, T.H.;Singh, Beer;Saxena, A.;Verma, A.K.;Shrivastava, S.;Roy, A.;Yadav, S.S.;Shrivastava, A.R.
    • Carbon letters
    • /
    • v.13 no.2
    • /
    • pp.109-114
    • /
    • 2012
  • A nuclear, biological, chemical (NBC) canister was indigenously developed using active carbon impregnated with ammoniacal salts of copper (II), chromium (VI) and silver (I), and high efficiency particulate aerosol filter media. The NBC canister was evaluated against carbon tetra chloride ($CCl_4$) vapours, which were used as a simulant for persistent chemical warfare agents under dynamic conditions for testing breakthrough times of canisters of gas masks in the National Approval Test of Respirators. The effects of $CCl_4$ concentration, test flow rate, temperature, and relative humidity (RH) on the breakthrough time of the NBC canister against $CCl_4$ vapour were also studied. The impregnated carbon that filled the NBC canister was characterized for surface area and pore volume by $N_2$ adsorption-desorption isotherm at liquid nitrogen temperature. The study clearly indicated that the NBC canister provides adequate protection against $CCl_4$ vapours. The breakthrough time decreased with the increase of the $CCl_4$ concentration and flow rate. The variation in temperature and RH did not significantly affect the breakthrough behaviour of the NBC canister at high vapour concentration of $CCl_4$, whereas the breakthrough time of the NBC canister was reduced by an increase of RH at low $CCl_4$ vapour concentration.

Electrochemical Properties of Porous Carbon Electrode as a Function of Internal Electrolyte Concentration (전극 내부의 전해질 농도 변화에 따른 다공성 탄소전극의 전기화학적 특성)

  • Park, Byeong-Hee;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.20 no.6
    • /
    • pp.700-704
    • /
    • 2009
  • The electrochemical properties of porous carbon electrodes as a function of their internal electrolyte concentration were investigated. Cyclic voltammetry, chronoamperometry, and impedance spectroscopic analysis were conducted for carbon electrodes equilibrated with 0.01, 0.05, 0.1, and 0.5 M KCl solution and covered with a cation-exchange membrane. The specific capacitance of the electrodes increased as the internal electrolyte concentration increased, due to a decrease in charging resistance. Experimental results indicated that the salt removal efficiency of the membrane capacitive deionization process could be enhanced by increasing the internal electrolyte concentration, even for an influent with a low salt concentration.

Lincomycin Production in the culture of Streptomyces lincolnensis using crude soybean oil in air lift bioreactor

  • Cho, Ki-An;Cho, Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.27-33
    • /
    • 2008
  • Using crude soybean oil as the sole carbon source, the lincomycin production from Streptomyces lincolnensis LC 345 was investigated in the air lift bioreactor. When 30 g/L of crude soybean oil was used, the maximum lincomycin concentration reached 0.89 g/L, after 5 days of culture. When CSL concentration was increased from 10 to 30 g/L, Lincomycin concentration was increased from 0.6 to 1.2. On the other hand, when CSL concentration was increased from 40 to 60 g/L, it was decreased from 1.15 to 0.7 g/L. Using these results, fed batch cultures for comparing the use of crude soybean oil and glucose as a conventional carbon source were carried out in a 5 L air lift bioreactor. When crude soybean oil was used as the sole carbon source, the maximum lincomycin concentration was 2.0 g/L, which was about 2.0 fold higher than that of glucose medium after 7 day of culture. The product yield from olive oil was 0.042 g/g consumed carbon source, which was about 3.8 fold higher than that of glucose.

Effects of carbon blacks on the electrical properties of EPDM compounds (EPDM 컴파운드의 전기적 특성에 미치는 카본블랙의 영향)

  • Lee, Chul-Ho;Cho, Yong-Suk;Jeon, Young-Jun;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1593-1595
    • /
    • 1999
  • Effects of carbon black species and concentration on the mechanical and electrical properties of alumina trihydrate filled EPDM compounds were investigated. Mechanical properties improved with increasing carbon black concentration, and these effects were prominent in carbon blacks haying large specific area. In the case of non-conductive carbon black. tracking resistance improved when a small amount of carbon black was added to EPDM. Conductive carbon black showed detrimental effect to dielectric losses, volume resistivity and tracking resistance of EPDM compound.

  • PDF

A Case of Acute Poisoning with Dry Ice (드라이아이스에 의한 급성 중독 1례)

  • Hwang, Soon-Young;Jung, Jin-Hee;Eo, Eun-Kyung
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.5 no.1
    • /
    • pp.43-45
    • /
    • 2007
  • Carbon dioxide is the fourth most abundant gas in the earth's atmosphere, and it is widely used in the chemical industry. Solid carbon dioxide is commonly known as dry ice. At low concentration, carbon dioxide appears to have little toxicological effect. At higher concentrations, however, it can produce an increased respiratory rate, tachycardia, cardiac arrhythmia, loss of consciousness, convulsion, and even death. Management of carbon dioxide poisoning requires the immediate removal of an individual from the toxic environment and administration of oxygen. It is important to know the concentration of carbon dioxide to which a patient has been exposed. We report a case of acute poisoning from solid carbon dioxide in a patient presenting with drowsiness and diminished mental capacity when she arrived in the emergency department. She recovered completely after administration of oxygen with conservative treatment.

  • PDF

Purification of Water Contaminants Using Activated Carbon Fiber Filter with Phenolic Resin Coated on Glass Fibers as a Precursor

  • Baek, Il-Hyun
    • Carbon letters
    • /
    • v.1 no.2
    • /
    • pp.82-86
    • /
    • 2000
  • The present research was undertaken to evaluate the possibility of water purification filter with activated carbon fibers (ACFs) using a very low cost precursor consisting of phenolic resin coated on glass fibers. The simplified procedure involving coating, curing and activation and a very low cost glass fiber as a raw material were adopted in order to reduce manufacturing cost. The breakthrough curves of the manufactured ACFs and the commercial activated carbon (AC, Calgon F-200) were investigated in the initial concentration range from 19 to 49 ppm for benzene, toluene and ethylbenzene. From breakthrough profiles, the manufactured ACFs had significantly faster adsorption kinetics than the AC. Especially the benzene breakthrough curves, the manufactured ACF (13 g of ACF with 32% of carbon on the glass) was over the limited level (5 ppb) after flowing of 32 l at initial concentration of 15 ppm, while the commercial AC was shown about 3 ppm in initial adsorption.

  • PDF

A Study on the Extinction Concentration of Inert Gas for Extinction Performance Estimation of Kerosene (등유의 소화성능 평가를 위한 불활성 가스의 소화농도에 관한 연구)

  • Choi, Jae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.34-38
    • /
    • 2007
  • The experiment was done to investigate extinguishing concentrations of different inert gases of verying concentrations made in contact with Kerosene. The experimental results obtained are as follows; at a standard amount of air flow was 40L/min, the extinguishing concentration of Argon, Nitrogen, Carbon dioxide and Helium for Kerosene were 36.5%, 27.3%, 17.4%, 12.3%, respectively. And, according to these results, Helium of 12.3% showed the lowest extinguishing concentration.

A Study on the Autoignition of Granulated Activated Carbon with Change of Oxygen Concentration (산소농도 변화에 따른 입상활성탄의 자연발화에 관한 연구)

  • 목연수;최재욱;류동현;최일곤;김상렬
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.84-91
    • /
    • 1995
  • The characteristics of critical spontaneous ignition of granulated activated carbon were investigated In atmospheres of differing oxygen concentration. At the same concentration the larger vessels yielded the lower critical spontaneous ignition temperature. At the same vessel, as the concentration of oxygen was reduced, Ignition occurred later and at higher ambient temperature, and critical spontaneous ignition temperature increased. The apparent activation energy calculated from the Frank-Kamenetskii's ignition theory appeared to be the slight different value respectively and the mean apparent activation energy was 19850㎈/㏖.

  • PDF

Influence of carbon type and carbon to nitrogen ratio on the biochemical methane potential, pH, and ammonia nitrogen in anaerobic digestion

  • Choi, Yongjun;Ryu, Jeongwon;Lee, Sang Rak
    • Journal of Animal Science and Technology
    • /
    • v.62 no.1
    • /
    • pp.74-83
    • /
    • 2020
  • Organic waste used as a feedstock in the anaerobic digestion (AD), it includes carbon and nitrogen. Carbon and nitrogen have an effect on the various digestive characteristics during AD, however, the study is rare about those of the interaction. This study investigates the influence of carbon type and carbon to nitrogens (C/N ratios) on the AD characteristics of organic waste. Experimental treatments involved a combination of three carbon types with three C/N ratios. The AD tests were carried out using a 125-mL serum bottle at a constant temperature of 37℃ and moisture 95% for 18 days. Degradation pattern shows the difference among three-carbon treatments, the starch group was faster than other groups. Maximum methane production date was similar between starch (9.96 ± 0.05 day) and xylan group (10.0 ± 0.52 day), those of the cellulose group (14.6 ± 1.80 day) was slower than other groups (p < 0.05). The lag phase was only affected by the carbon type (p < 0.05). Ammonia nitrogen was mainly affected by nitrogen concentration regardless of carbon type (p < 0.05). This study showed that xylan is useful as feedstock in order to decrease the lag phase, and it showed that ammonia was independently affected by the nitrogen concentration.

Combustion Emission Gas Analysis and Health Hazard Assessment about P. densiflora and Q. variabilis Surface Fuel Beds (소나무, 굴참나무 낙엽의 연소 방출가스 분석 및 건강 위험성 평가)

  • Kim, Dong-Hyun;Kim, Eung-Sik;Lee, Myung-Bo
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.24-31
    • /
    • 2009
  • Based on fallen leaves of major Korean conifer species 'Pinus densiflora' and major Korean broadleaved species 'Quercus variabilis', this study sought to identify combustion emission gas types and measure their concentration by means of FTIR (Fourier Transform Infrared) spectrometer. As a result, it was found that there were total 13 types of combustion gas detected from fallen leaves of Pinus densiflora and Quercus variabilis, such as carbon monoxide, carbon dioxide, acetic acid, butyl acetate, ethylene, methane, methanol, nitrogen dioxide, ammonia, hydrogen fluoride, sulfur dioxide and hydrogen bromide. Notably, nitrogen monoxide was additionally detected from fallen leaves of Quercus variabilis. It was found that the overall concentration of combustion gas emitted from the fallen leaves of Pinus densiflora was 4.5 times higher than that from fallen leaves of Quercus variabilis. Particularly, it was found that emission concentration of some combustion emission gas types like carbon monoxide, carbon dioxide and butyl acetate exceeded the upper limit of their time-weighted average (TWA, ppm), while the emission concentration of carbon monoxide and carbon dioxide exceeded their short-term exposure limit (STEL, ppm) for both species. Thus, it was found that carbon monoxide and carbon dioxide have higher hazard to health than other gas types, because these two gas types account for higher than 99% of overall gas emission due to combustion of surface fire starting from litter layer in forest.