• Title/Summary/Keyword: Capillary Flow

Search Result 383, Processing Time 0.026 seconds

An experimental study on the viscosity of visco-elastic fluids (점탄성유체의 점성에 관한 실험적 연구)

  • 김춘식;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.21-41
    • /
    • 1982
  • Viscosity, especially characteristic among various properties of visco-elastic fluids such as high polymer solutions, is affected mainly by temperature and concentration. Hence, it is important for fluid engineering to express, by some equations, how the fluid characteristics vary with the change of temperature and concentration and to analyze them to obtain consistent viscous characteristics. High polymer solutions, synthetic products of modern chemical industry, suggest many interesting investigations because they are typical visco-elastic materials. Experimentation was made to derive some useful fluid characteristic equations of SEPARAN-NP10 (polyacylamide) expressed by n (flow behavior index) and K' (consistency index) when it is given temperature and concentration variation. To measure viscosity, capillary viscometer was adopted and the range of experimentation is 0-2,000 P.P.M. in concentration and 15-55 .deg.C in temperature. The experimental results are summarized as follows: The flow behavior index n 1) has nearly constant results irrespective of temperature variation at same conentration and the results are shown in (Table. 4-4-3) 2) has following equation, regardless of temperature, for the variation of concentration. n=-1.0765*10$^{-4}$ P+0.9915 (P:P.P.M.) The consistency index K' 1) has different results for the variation of temperature at same concentration and the results are given in (Table.4-7-2) 2) has following equation for the variation of concentration at same temperature. log 10$^{4}$K' =6.4785*10$^{-4}$ P-1.0529 (P:P.P.M)

  • PDF

Processing of Kaolin-Based Microfiltration Membranes

  • Eom, Jung-Hye;Kim, Young-Wook;Song, In-Hyuck
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.5
    • /
    • pp.341-347
    • /
    • 2013
  • Kaolin-based membranes with a pore size of 0.30-0.40 ${\mu}m$ were successfully prepared by a simple pressing route using low-cost starting materials, kaolin and sodium borate. The prepared green bodies were sintered at different temperatures ranging between 900 and $1200^{\circ}C$. The sintered membranes were characterized by X-ray diffraction, mercury porosimetry, scanning electron microscopy, and capillary flowmetry. It was observed that the porosity decreased with an increase in both the sintering temperature and the sodium borate content, whereas the flexural strength increased with an increase in both the sintering temperature and the sodium borate content. The air flow rate decreased with an increase in the sodium borate content. The typical porosity, flexural strength, and specific flow rate of the kaolin-based membrane sintered with 5 wt% sodium borate at $1100^{\circ}C$ were 37%, 19 MPa, and $1{\times}10^{-3}L/min/cm^2$, respectively, at a p of 30 psi.

Study of Ceramic Sub-Micron Particle Patterning by Electro-Hydrodynamic Printing (전기-수력학 프린팅을 이용한 세라믹 미세입자 패턴에 관한 연구)

  • Lee Dae-Young;Kim Sang-Yoon;Yu Tae-U;Kim Yong-Jun;Hwang Jungho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.504-511
    • /
    • 2005
  • The generation of fine relics of inorganic and metallic materials from precursor suspensions is of significant current interest as it holds the key to the fabrication of display and printed circuit board. Some novel printing methods depositing ceramic particles have been suggested in recent years. When a conducting liquid is supplied to a capillary nozzle at a low flow rate and when the interface between air and the liquid is charged to a sufficiently high electrical potential, the liquid meniscus takes the form of a stable cone, whose apex emits a microscopic jet. This is called as a cone-jet mode. In our experiments, an alumina particles flowing through a nozzle were subjected to electro-hydrodynamic printing in the cone-jet mode. The pattern of 'YONSEI' characters was tested at $10 {\mu}l/min$ of alumina ink flow rate and different applied voltages. At an applied voltage of 6 kV, feature size was in the range of $250 {\mu}m.$

A study of gingival blood flow using laser Doppler flowmetry (Laser Doppler Flowmetry를 이용한 치은혈류량에 관한 연구)

  • Kim, Hyung Soo;Lee, Zang-Hee;Song, Hyung-Geun;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.309-320
    • /
    • 1998
  • The periodontal health has been evaluated clinically by various epidemiological indices, and in researches by measurement of gingival crevicular fluid. Laser Doppler flowmetry is a reliable and objective method that allows immediate measurement of erythrocyte flux in approximately one cubic mm of the capillary bed without disturbing the tissues. The purpose of the present study was to determine whether human gingival blood flow was different according to measuring area, measuring time, and sex or not. Forty volunteers with good general and periodontal health, aged early twenties and unmarried, were selected. Laser Doppler flowmetry($floLAB^{(R)}$, Moor Instruments Ltd., England) was applied to measure the gingival blood flow of marginal gingiva, interdental papilla, attached gingiva and alveolar mucosa. The blood flow of interdental papilla was measured at 9-10 AM, 1-2 PM, and 5-6 PM. The difference of blood flow according to measuring area and measuring time was statistically analyzed by one way AOVA and Dunkan test, and the difference of blood flow between men and women was statistically analyzed by t-test. (1) Mean blood flow was significantly higher in alveolar mucosa than in the gingiva(p<0.05), and there was no significant difference in blood flow between marginal gingiva and interdental papilla(p>0.1). (2) Mean blood flow was significantly higher at 5-6 PM than at 9-10 AM and 1-2 PM(p<0.05). But there was no significant difference in gingival blood flow between 9-10 AM and 1-2 PM(p>0.1). (3) There was no significant difference in gingival blood flow between men and women(p>0.1). The above results suggest that the measurment of gingival blood flow using laser Doppler flowmetry may be clinically applicable to early determination of gingival inflammation and evaluation of healing status, but further studies are necessary to standardize and simplify the measuring procedure.

  • PDF

Performance Analysis of the Soft Ice-cream Maker Having Two Evaporators Operating at Different Temperatures (두개의 증발기가 장착된 소프트 아이스크림 제조기의 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.517-522
    • /
    • 2013
  • Small size ice-cream maker has two evaporators having different evaporating temperatures of $4^{\circ}C$ and $-8^{\circ}C$. In such case, ice-cream maker system design becomes complicated because multiple capillary tubes affects one another. In this study, performance analysis was conducted for the soft ice-cream maker having two evaporators operating at different temperatures. The compressor was analyzed using efficiency models, the capillary tube was modeled assuming one-dimensional flow, the condenser and the evaporators were modeld based on UA-LMTD method. The refrigeration cycle simulation program was developed applying the enthalpy, pressure and mass balance on each component. Comparison of the test data with the simulated results for R404A revealed that evaporator temperatures of refrigerator and freezer agreed within $3^{\circ}C$.

Numerical Investigation on Two-Dimensional Inviscid Edge Receeding of a Stationary Fluid Sheet (정지된 2차원 액체 필름 끝단의 비점성 수축특성에 관한 수치연구)

  • Ahn, Ja-Il;Song, Mu-Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.2
    • /
    • pp.107-111
    • /
    • 2007
  • A two-dimensional numerical method for inviscid two-fluid flows with evolution of density interface is developed, and an initially stationary two-dimensional fluid sheet surrounded by another fluid is studied. The interface between two fluids is modeled as a vortex sheet, and the flow field with the evolution of interface is solved by using vortex-in-cell/front-tracking method. The edge of the sheet is pulled back into the sheet due to surface tension and a blob is formed at the edge. This blob and fluid sheet are connected by a thin neck. In the inviscid limit, such process of the blob and neck formation is examined in detail and their kinematic characteristics are summarized with dimensionless parameters. The edge recedes at and the capillary wave propagating into the fluid sheet must be considered for better understanding of the edge receding.

  • PDF

Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode (Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템)

  • Yi In-Je;Kang Chi-Jung;Kim Yong-Sang;Kim Ju-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

Effects of Sagungsan on the Hemostasis, Intracranial Pressure, Blood Pressure and Cardiovascular System in Expreimental Animals (사궁산(莎芎散)이 실험동물(實驗動物)의 지혈(止血), 뇌압(腦壓), 혈압(血壓) 및 심혈관계(心血管系)에 미치는 영향(影響))

  • An, Il-Hoe;Park, Young-Soon;Kim, Seh-Gil
    • The Journal of Internal Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.80-98
    • /
    • 1994
  • According to the original documents, Sagungsan is considered as an effective drug for controlling the hypertensive epistaxis induced by tension of autonomic nerve and it's hyperfunction. The present experiment was designed to understand the effect of Sagungsan extract on the hemostatic action, intracranial pressure, blood pressure and cardiovascular system in experimental animals. And thus the bleeding time, prothrombin time, capillary dilation, blood pressure, Intracranial pressure, and enzymatic analysis of the ATPase activities were studied. The result obtained here were as followings: 1. Sagungsan water extract reduced the bleeding time in mouse, and prolonged the prothrombin time in rabbits. 2. The drug extract increased the tail volume by capillary dilation in rats. 3. The drug extract inhibited the increase of intracranial pressure and arterial blood pressure in rabbits. 4. At the early time, the increase of arterial blood pressure by the drug extract significantly inhibited by pretreated atropin and regitine in rabbits. 5. The drug extract relaxed the smooth muscle by stimulating the Mg2+-Ca2+-ATPase activities of gastric sarcoplasmic reticulum isolated from rabbit stomach. 6. The drug extract stimulated the heart contraction by inhibiting the $Mg^{2+}-Ca^{2+}-ATPase$ activities of cardiac sarcoplasmic reticulum isolated from rabbit heart. The inhibitory mechanism was reversible and noncompatitive. 7. The drug extract increased the hepatic blood volume by stimulating the hepatic total ATPase activities and hepatic metabolism. 8. The drug extract acted as a tranquilizer by inhibiting the neural Na+-K+-ATPase activity. According to the results, Sagungsan water extract dilated the capillaries, stimulated the heart beat, and thus increased the blood flow with decreasing the intracranial pressure and blood pressure. These effects stanches the epistaxis collectively.

  • PDF

Bioseparations in Lab-On-A-Chip (랩온어칩에서의 생물분리기술)

  • Chang Woo-Jin;Koo Yoon-Mo
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.197-204
    • /
    • 2005
  • Lab-on-a-chip is a miniaturized analytical device in which all of the procedures for the analysis of molecules are carried out, such as pretreatment, reaction, separation, detection, etc. Lab-on-a-chip has increasing concern as a device not only for rapid detection of molecules but also for high throughput screening and point of care, because conventional laborious and time consuming analytical procedures can be substituted. Thus, a lot of microfabrication and analytical techniques for lab-on-a-chip have been developed with microstructures smaller than a few hundreds of micrometers. Separation of the molecules is one of the most important components of lab-on-a-chip, because effective separation method can simplify the design and can provide better sensitivity. The electrokinetic separation based on capillary electrophoresis is most widely employed technique in lab-on-a-chip for the control of fluids and the separation of molecules. In this article, bioseparation techniques and its applications realized in lab-on-a-chip are reviewed.

Effect of Carbon Black Concentration and Monomer Compositional Ratio on the Flow Behavior of Copoly(styrene/butyl methacrylate) Particles (카본블랙의 농도 및 단량체 구성비에 따른 스티렌-부틸메타크릴레이트 공중합체 입자의 유동성)

  • Park, Moon-Soo;Moon, Ji-Yeon
    • Elastomers and Composites
    • /
    • v.45 no.2
    • /
    • pp.122-128
    • /
    • 2010
  • We measured shear viscosity of copoly(styrene(St)/butyl methacrylate(BMA)) (co-PSB) particles, with a capillary rheometer at $170^{\circ}C$, prepared by suspension polymerization with hydrophobic silica as a stabilizer. co-PSB particles with the weight average molecular weights of lower than 74,800 g/mol displayed a Newtonian behavior at low shear rates. With the weight average molecular weight exceeding 136,800 g/mol, co-PSB particles showed shear thinning against shear rates and the absolute value of the slopes between shear viscosity vs. shear rate increased. When the ratio between St and BMA changed from 7/3 to 5/5 to 3/7, shear viscosity and glass transition decreased despite similar molecular weights. When the ratio was 1/9, it showed a large increase in initial shear viscosity despite reduced glass transition. Shear viscosity exhibited an increase in proportion to carbon black concentration. The effect of carbon black concentration on the shear viscosity of co-PSB composites was less pronounced compared to varying molecular weights and/or compositional ratio.