• Title/Summary/Keyword: Capillary Blood Glucose

Search Result 21, Processing Time 0.026 seconds

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

Screening for diabetes mellitus using gingival crevicular blood with the help of a self-monitoring device

  • Gaikwad, Subodh;Jadhav, Varsha;Gurav, Abhijit;Shete, Abhijeet R.;Dearda, Hitesh M.
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.1
    • /
    • pp.37-40
    • /
    • 2013
  • Purpose: The purpose of study was to compare blood glucose in capillary finger-prick blood and gingival crevice blood using a self-monitoring blood glucose device among patients with gingivitis or periodontitis. Methods: Thirty patients with gingivitis or periodontitis and bleeding on probing (BOP) were chosen. The following clinical periodontal parameters were noted: probing depth, BOP, gingival bleeding index, and periodontal disease index. Blood samples were collected from gingival crevicular blood (GCB) and capillary finger-prick blood (CFB). These samples were analyzed using a glucose self-monitoring device. Results: Descriptive statistical analysis has been carried out in the present study. Data were analyzed using a Pearson's correlation coefficient and Student's t-test. A r-value of 0.97 shows very strong correlation between CFB and GCB, which was statistically highly significant (P<0.0001). Conclusions: The authors conclude that GCB may serve as potential source of screening blood glucose during routine periodontal examination in populations with an unknown history of diabetes mellitus.

Analytical Evaluation of PPG Blood Glucose Monitoring System - researcher clinical trial (PPG 혈당 모니터링 시스템의 분석적 평가 - 연구자 임상)

  • Cheol-Gu Park;Sang-Ki Choi;Seong-Geun Jo;Kwon-Min Kim
    • Journal of Digital Convergence
    • /
    • v.21 no.3
    • /
    • pp.33-39
    • /
    • 2023
  • This study is a performance evaluation of a blood sugar monitoring system that combines a PPG sensor, which is an evaluation device for blood glucose monitoring, and a DNN algorithm when monitoring capillary blood glucose. The study is a researcher-led clinical trial conducted on participants from September 2023 to November 2023. PPG-BGMS compared predicted blood sugar levels for evaluation using 1-minute heart rate and heart rate variability information and the DNN prediction algorithm with capillary blood glucose levels measured with a blood glucose meter of the standard personal blood sugar management system. Of the 100 participants, 50 had type 2 diabetes (T2DM), and the average age was 67 years (range, 28 to 89 years). It was found that 100% of the predicted blood sugar level of PPG-BGMS was distributed in the A+B area of the Clarke error grid and Parker(Consensus) error grid. The MARD value of PPG-BGMS predicted blood glucose is 5.3 ± 4.0%. Consequentially, the non-blood-based PPG-BGMS was found to be non-inferior to the instantaneous blood sugar level of the clinical standard blood-based personal blood glucose measurement system.

Effects of Bisphosphonates on Glucose Transport in a Conditionally Immortalized Rat Retinal Capillary Endothelial Cell Line (TR-iBRB Cells)

  • Lee, Na-Young;Park, Hyun-Joo;Kang, Young-Sook
    • Biomolecules & Therapeutics
    • /
    • v.24 no.1
    • /
    • pp.94-98
    • /
    • 2016
  • The objective of the present study was to elucidate the effect of bisphosphonates, anti-osteoporosis agents, on glucose uptake in retinal capillary endothelial cells under normal and high glucose conditions. The change of glucose uptake by pre-treatment of bisphosphonates at the inner blood-retinal barrier (iBRB) was determined by measuring cellular uptake of $[^3H]3$-O-methyl glucose (3-OMG) using a conditionally immortalized rat retinal capillary endothelial cell line (TR-iBRB cells) under normal and high glucose conditions. $[^3H]3$-OMG uptake was inhibited by simultaneous treatment of unlabeled D-glucose and 3-OMG as well as glucose transport inhibitor, cytochalasin B. On the other hand, simultaneous treatment of alendronate or pamidronate had no significant inhibitory effect on $[^3H]3$-OMG uptake by TR-iBRB cells. Under high glucose condition of TR-iBRB cells, $[^3H]3$-OMG uptake was increased at 48 h. However, $[^3H]3$-OMG uptake was decreased significantly by pre-treatment of alendronate or pamidronate compared with the values for normal and high glucose conditions. Moreover, geranylgeraniol (GGOH), a mevalonate pathway intermediate, increased the uptake of $[^3H]3$-OMG reduced by bisphosphonates pre-treatment. But, pre-treatment of histamine did not show significant inhibition of $[^3H]3$-OMG uptake. The glucose uptake may be down regulated by inhibiting the mevalonate pathway with pre-treatment of bisphosphonates in TR-iBRB cells at high glucose condition.

Effects of endurance exercise under hypoxia on acid-base and ion balance in healthy males

  • Nam, Sang-Seok;Park, Hun-Young
    • Korean Journal of Exercise Nutrition
    • /
    • v.24 no.3
    • /
    • pp.7-12
    • /
    • 2020
  • [Purpose] This study was performed to investigate the acid-base and ion balance at rest and after exercise in healthy males under normoxia, moderate hypoxia, and severe hypoxia. [Methods] Ten healthy Korean males completed three different trials on different days, comprising exercise under normoxia (FiO2 = 20.9%, N trial), moderate hypoxia (FiO2 = 16.5%, MH trial), and severe hypoxia (FiO2 = 12.8%, SH trial). They undertook endurance exercise for 30 min on a cycle ergometer at the same relative exercise intensity equivalent to 80% maximal heart rate under all conditions. Capillary blood samples were obtained to determine acid-base and ion balance at rest and after exercise. [Results] Exercise-induced blood lactate elevations were significantly increased as hypoxic conditions became more severe; SH > MH > N trials (P = 0.003). After exercise, blood glucose levels were significantly higher in the SH trial than in the N and MH trials (P = 0.001). Capillary oxygen saturation (SCO2) levels were significantly lowered as hypoxic conditions became more severe; SH > MH > N trials (P < 0.001). The pH levels were significantly lower in the MH trial than that in the N trial (P = 0.010). Moreover, HCO3- levels were significantly lower in the SH trial than in the N trial, with significant interaction (P = 0.003). There were no significant differences in blood Na+, K+, and Ca2+ levels between the trials. [Conclusion] MH and SH trials induced greater differences in glucose, lactate, SCO2, pH, and HCO3- levels in capillary blood compared to the N trial. Additionally, lactate, SCO2, and HCO3- levels showed greater changes in the SH trial than in the MH trial. However, there were no significant differences in Na+, K+, and Ca2+ levels in MH and SH trials compared to the N trial.

Measurement Accuracy of Blood Glucose Test on the Forearm (전완 부위 혈당검사의 정확도 분석)

  • Park, Kyung-Soon;Song, Yeon-Yi;Park, Mi-Sook;Kim, Kyoung-Oak;Choi, Seong-Su;Kim, Kyung-Ah;Ryu, Jae-Duck;Cha, Eun-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2451-2459
    • /
    • 2009
  • The present study aimed to evaluate the accuracy of the blood glucose test with almost painless vacuum assisted auto-lancing technique. The blood glucose concentration measurements in the capillary blood sampled from the alternative (forearm) site were compared with the standard venous or finger sampling techniques. Capillary blood was sampled from both the left index finger and the forearm, followed by the venous blood sampling in 531 patients who visited the C University Hospital. Blood sugar test was performed for each blood samples for comparative analysis. Mean blood glucose concentration measured on the forearm was closer to the venous glucose level than that of the finger, but the difference was approximately 10 mg/dL small enough to ignore from the clinical point of view. The correlation coefficients of the measured blood glucose levels between finger and vein and between forearm and vein were 0.94 and 0.92, respectively (p<0.001). The blood glucose measurement on the forearm also well correlated with the finger, showing a correlation coefficient of 0.94, and both data were very much close to each other. Therefore, the blood sugar test on the alternative capillary blood sampling site such as forearm was accurate enough for clinical practice. The vacuum assisted auto-lancing technique on the alternative site would be of particular interest for the disease management of the chronic diabetes, since it induces almost no pain when sampling blood from the capillaries.

A Clinical Report of Yagwanchunghyul-tang's Effect on a Metabolic Syndrome Patient (야관청혈탕(夜關淸血湯) 투여 후 증상 호전된 대사증후군 환자 1례 보고)

  • Jung, Ho-Young;Cho, Chung-Sik;Kim, Chul-Jung
    • Journal of Haehwa Medicine
    • /
    • v.19 no.2
    • /
    • pp.173-177
    • /
    • 2011
  • We treated a 45 year-old male patient. He had Hypertension, Diabetes, Hyperlipidemia and Obesity. The main symptoms were Low-back pain, General body weakness, Abdominal discomfort. We diagnosed him as metabolic syndrome and prescribe Yagwanchunghyul-tang three times a day. We observed clinical symptoms Blood pressure, Capillary blood glucose, BMI, Body weight. Cholesterol, Triglyceride. After the treatment, The main symptom, blood pressure, capillary blood glucose(PP2hr), Hypercholesterol, Hypertriglyceride were improved. and BMI levels fell. This case shows that Yagwanchunghyul-tang has an effect on Metabolic syndrome like a Hypertension, Diabetes, Hyperlipidermia, Hypertriglyceride.

A Study of the Chaotic Analysis of Flow of Capillary Blood Vessel by glucose index (Rabbit의 당수치에 따른 모세혈관 혈류의 카오스적 분석에 대한 연구)

  • Choi, J.Y.;Cho, C.Y.;Kim, D.H.;Im, J.D.;Im, J.J.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.258-262
    • /
    • 1996
  • The physiological systems have nonlinear complex phenomena. Expecially, the flow of capillary blood vessel has a nonlinear dynamic system. Thus, this study analyzes nonlinear characteristics of the flow of capillary blood vessel in physiological systems using chaotic tools(phase space reconstruction, correlation dimension, largest lyapunov exponent). Experimental data have been acquired from examining 10 rabbits. The results of chaotic analysis showed a decreasing largest lyapunov exponent and correlation dimension according to increasement glocose index. And we also know the chaotic behavior.

  • PDF

Accuracy Evaluation of the Alternative Site Blood Glucose Test Using Error Grid (에러그리드를 사용한 대체부위 혈당검사의 유용성 검증)

  • Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • Blood glucose information is important for self regulation in daily life, but the frequency of self test remains to be only 17%(9 tests/month) in Korea, mainly due to pain during blood sampling. The present study tried to validate the clinical efficacy of the forearm as an alternative sampling site with minimized pain. Capillary blood was sampled both on the index finger($G_F$) and the forearm($G_A$), immediately followed by glucose measurements in 531 subjects, 25 who visited the Health Enhancement Center of C University Hospital, then venous blood($G_V$) was sampled for glucose test. The blood glucose concentration measured on the forearm was closer to the venous glucose than on the finger. The mean difference between $G_V$and $G_F$ was only 10 mg/dL well within the internationally accepted error limit. Error grid analyses of $G_F-G_V$, $G_A-G_V$ and $G_A-G_F$ revealed that the number of data points in regions A and B took 100%, 99.8%, and 97.9%, respectively. These results demonstrate the forearm blood glucose test is not only accurate but also clinically valid. Therefore, the forearm blood glucose test can be a useful way of self managing the chronic diabetes with minimized sampling pain.

Effect of Wheat Flour Noodles with Bombyx mori Powder on Glycemic Response in Healthy Subjects

  • Suk, Wanhee;Kim, JiEun;Kim, Do-Yeon;Lim, Hyunjung;Choue, Ryowon
    • Preventive Nutrition and Food Science
    • /
    • v.21 no.3
    • /
    • pp.165-170
    • /
    • 2016
  • Recent trial results suggest that the consumption of a low glycemic index (GI) diet is beneficial in the prevention of high blood glucose levels. Identifying active hypoglycemic substances in ordinary foods could be a significant benefit to the management of blood glucose. It has been hypothesized that noodles with Bombyx mori powder are a low GI food. We evaluated GI and changes in postprandial glucose levels following consumption of those noodles and compared them with those following consumption of plain wheat flour noodles (control) and glucose (reference) in healthy subjects. Thirteen males (age: $34.2{\pm}4.5years$, body mass index: $23.2{\pm}1.1kg/m^2$) consumed 75 g carbohydrate portions of glucose and the 2 kinds of noodle after an overnight fast. Capillary blood was measured at time 0 (fasting), 15, 30, 45, 60, 90, 120, and 180 min from the start of each food intake. The GI values were calculated by taking the ratio of the incremental area under the blood glucose response curve (IAUC) for the noodles and glucose. There was a significant difference in postprandial glucose concentrations at 30 and 45 min between the control noodles and the noodles with Bombyx mori powder: the IAUC and GI for the noodles with Bombyx mori powder were significantly lower than those for glucose and plain wheat flour noodles. The wheat flour noodles with Bombyx mori powder could help prevent an increase in postprandial glucose response and possibly provide an alternative to other carbohydrate staple foods for glycemic management.