• Title/Summary/Keyword: Capillary

Search Result 1,974, Processing Time 0.035 seconds

Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System (모세유관 바닥복사 냉·난방 시스템의 성능평가)

  • Seo, Yu-jin;Kim, Taeyeon;Leigh, Seung-bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

Decrease in the Thickness of Capillary Fringe Induced by Surface Active Chemicals in the Groundwater (계면활성물질의 지하수적용에 의한 모관수대 두께의 감소)

  • Kim, Heonki;Shin, Seungyup;Yang, Haewon
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.52-58
    • /
    • 2012
  • Capillary fringe divides the groundwater and the vadose zone controlling the diffusive mass transfer of contaminants and gases. The thickness of capillary fringe is of great importance for the rate of contaminant mass transfer across the capillary fringe. Application of surface active chemicals including surfactants and alcohol-based products into the subsurface environment changes the surface tension of the aqueous phase, which in turn, affects the thickness of the capillary fringe. In this study, a bench-scale model was used to assess the quantitative relationship between the surface tension and the thickness of the capillary fringe. An anionic surfactant (Sodium dodecylbenzene sulfonate, SDBS) and an aqueous solution of ethanol were used to control the surface tension of the groundwater. It was found that the thickness of the capillary fringe is directly proportional to the surface tension. The air entry pressures measured by the Tempe Pressure Cell at different surface tensions using SDBS (200 mg/L) and ethanol (20%, v/v) solutions were in good agreement with the thicknesses of the capillary fringe measured by the model. A simple method to correct the conventional Brooks-Corey model for estimating the air entry pressure was also presented.

Case of Surgical Treatment with Free Flap on Large Size Facial Capillary Malformation (안면부 모세혈관기형에 따른 광범위 안면부 결손의 유리피판술을 이용한 치험례)

  • Kim, Do-Hoon;Pyon, Jai-Kyong;Mun, Goo-Hyun;Bang, Sa-Ik;Oh, Kap-Sung;Lim, So-Young
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.60-63
    • /
    • 2011
  • Capillary malformation is common vascular malformation. In case of facial capillary malformation, patients' cosmetic and functional deficits are quite significant. The standard treatment which has been applied so far for capillary malformation is pulsed dye laser with 585nm. But in case of advanced capillary malformation, surgical interventions are inevitable. The problem of large size facial capillary malformation is how to cover the remnant defect, which occurs after resection. In this case, authors have experienced surgical treatment of large size facial capillary malformation and covered the large facial defect with free thoracodorsal artery perforator flap. The flap was thick, so facial asymmetry remained after the first surgery. But with the secondary procedure, authors have made more symmetric figures. The patient was satisfied with the result. Using free flap to replace the defect after resection due to capillary malformation is useful for these kinds of cases.

  • PDF

Selection of Capillary Tubes for HCFC-22 Alternative Fluids (HCFC-22 대체냉매의 모세관 선정)

  • Jung, D.S.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.435-449
    • /
    • 1995
  • In this paper, pressure drop through a capillary tube is modeled to determine the length of a capillary tube for a given set of conditions. HCFC-22 and its alternatives, HFC-134a, R407B, and R410A are used as working fluids. The conditions on which the model is tested are as follows : condensing temperature; 40.0, 45.0, 50.0, $55.0^{\circ}C$, degree of subcooling;0.0, 2.5, $5.0^{\circ}C$, capillary tube exit condition;choked flow, capillary tube diameter;1.2~2.4mm, mass flow rate;5.0~50.0g/sec. The results justify the use of Stoecker's model which yields the results very close to the values in ASHRAE handbook. While McAdams' method yields much better results than Duckler's in calculating the viscosity of the fluid in 2-phase, the friction factor suggested by Stoecker seems to be the best for capillary tubes of large diameter used in residential air conditioners. For each refrigerant, 372 data with various variables are calculated by the model. The results show that capillary tube length varies very uniformly with changes in condensing temperature and degree of subcooling. Based on this fact, regression analysis is performed to determine the dependence of mass flow rate on the length and diameter of a capillary tube, condensing temperature, and degree of subcooling. Thus determined correlation yields a mean deviation of 2.36% for 1,488 data, showing an excellent agreement.

  • PDF

Capillary Bundle Model for the Estimation of Air-water Interfacial Area and the Gas-filled Pore Size Distribution in Unsaturated Soil (모세관 모델을 이용한 불포화토양의 물-가스 접촉면적 및 가스공극 크기분포의 계산 및 검증)

  • Kim, Heonki
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Air-water interfacial area is of great importance for the analysis of contaminant mass transfer processes occurring in the soil systems. Capillary bundle model has been proposed to estimate the specific air-water interfacial areas in unsaturated soils. In this study, the measured air-water interfacial areas of a soil (loam) using the gaseous interfacial tracer technique were compared to those from capillary bundle model. The measured values converged to the specific solid surface area (7.6×104 ㎠/㎤) of the soil. However, the simulated air-water interfacial areas based on the capillary bundle model deviated significantly from those measured. The simulated values were substantially over-estimated at low end of the water content range, whereas the model under-estimated the air-water interfacial area for the most of the water content range. This under-estimation is considered to be caused by the nature of the capillary bundle model that replaces the soil pores with a bundle of glass capillaries and thus no surface roughness at the inner surface of the capillaries is taken into account for the estimation of the air-water interfacial area with the capillary bundle model. Subsequently, appropriate correction is necessary for the capillary bundle model to estimate the air-water interfacial area in soils. Since the soil-moisture release curve data is the basis of the capillary bundle model, the model can be of use due to its simplicity, while the gaseous tracer technique requires complicated experimental equipment followed by moment analysis of the breakthrough curves. The size distribution profile of the pores filled with gas estimated by the water retention curve was found to be similar to that of particle size at different size range. The shifted distribution of gas-filled pores toward smaller size side compared to the particle size distribution was also found.

Characterization of Two Ricin Isoforms by Sodium Dodecyl Sulfate-Capillary Gel Electrophoresis and Capillary Isoelectric Focusing

  • Na, Dong-Hee;Park, Eun-Ji;Kim, Myung-Sun;Cho, Cheong-Kwan;Woo, Byung-Ho;Lee, Hye-Suk;Lee, Kang-Choon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4253-4257
    • /
    • 2011
  • Sodium dodecyl sulfate-capillary gel electrophoresis (SDS-CGE) and capillary isoelectric focusing (CIEF) were employed to characterize and compare ricin E purified from the small grain seeds of Ricinus communis with ricin D isoform. During the purification of ricin E using ion-exchange and size-exclusion chromatography, SDS-CGE was found to be useful for monitoring the efficiencies of purification steps. SDS-CGE showed that the molecular size of ricin E was not significantly different from that of ricin D, which was confirmed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. CIEF was useful for discriminating ricin E from ricin D based on their isoelectric points (pI). The pI values of ricin E and D were 8.6-8.8 and 7.0-7.4, respectively. This study demonstrates the usefulness of SDS-CGE and CIEF for the characterization of ricin toxins.

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size (인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구)

  • Choi, J.M.;Kim, Y.C.;Kim, J.Y.;Bae, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Preparation of Three Different Style Packed Capillary Frits

  • Ryoo, Jae-Jeong;Song, Young-Ae;Lee, Kwang-Pill;Park, Ji-Yeon;Choi, Seong-Ho;Hyun, Myung-Ho;Ohta, Kazutoku;Fujimoto, Chuzo;Jin, Ji-Ye;Takeuchi, Toyohide;Lee, Jung-Whan
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.524-528
    • /
    • 2006
  • Three different style capillary columns, a packed capillary with temporary quartz wool frit, a packed capillary with immobilized frit, and an immobilized packed-capillary, were easily prepared with a commercially available (S)-N-(3,5-dinitro-benzoyl)leucine-N-phenyl-N-alkylamide derived chiral stationary phase. Liquid chromatographic chiral separations of some racemic amino acid derivatives on these columns were performed and the results were compared to each other. The packed capillary with immobilized frit showed some merits in chiral chromatography.

Capillary Telangiectasia of the Posterior Fossa Presenting with Repeated Cerebellar Hemorrhage - A Case Report - (반복적인 소뇌 출혈로 발현한 후두와 모세혈관 확장증 - 증례보고 -)

  • Lee, Yong-Mook;Koh, Hyeon-Song;Cho, Jun-Hee;Youm, Jin-Young;Song, Shi-Hun;Kim, Youn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.211-216
    • /
    • 2001
  • Hemorrhage due to capillary telangiectasia is rare. We report a case of capillary telangiectasia presenting with repeated cerebellar hemorrhage in a 38-year-old male. To our knowledge this is the first case of repeated cerebellar hemorrhage from the capillary telangiectasia. At the first operation, we removed hematoma only, but rebleeding occurred repeatedly in the same area. Finally, we evacuated the recurrent hematoma and vascular mass of capillary telangiectasia at the second operation under surgical microscope. Based on the findings of this case and a review of the literature, we conclude that capillary telangiectasia can be the cause of the massive repeated hemorrhage.

  • PDF