• Title/Summary/Keyword: Capacity of use

Search Result 3,259, Processing Time 0.028 seconds

Optimization of Protocol for Injection of Iodinated Contrast Medium in Pediatric Thoracic CT Examination (소아 흉부 CT검사에서 조영제 주입에 관한 프로토콜의 최적화)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.879-887
    • /
    • 2019
  • The purpose of this study is to establish a physiological injection protocol according to body weight, in order to minimize amount of contrast medium and optimize contrast enhancement in pediatric patients performing thoracic CT examinations. The 80 pediatric patients under the age of 10 were studied. Intravenous contrast material containing 300 mgI/ml was used. The group A injected with a capacity of 1.5 times its weight, and groups B, C and D added 5 to 15 ml of normal saline with a 10% decrease in each. The physiologic model which can be calculated by weight about amount of injection of contrast medium and normal saline, flow rate and delay time were applied. To assess image quality, measured average HU value and SNR of superior vena cava, pulmonary artery, ascending and descending aorta, right and left atrium, right and left ventricle. CT numbers of subclavian vein and superior vena cava were compared to identify the effects of reducing artifacts due to normal saline. Comparing SNR according to the contrast medium injection protocol, significant differences were found in superior vena cava and pulmonary artery, descending aorta, right and left ventricle, and CT numbers showed significant differences in all organs. In particular, B group with a 10% decrease in contrast medium and an additional injection of saline showed a low degree of contrast enhancement in groups with a decrease of more than 20%. In addition, the group injected with normal saline greatly reduced contrast enhancement of subclavian vein and superior vena cava, and the beam hardening artifact by contrast medium was significantly attenuated. In conclusion, the application of physiological protocol for injection of contrast medium in pediatric thoracic CT examinations was able to reduce artifacts by contrast medium, prevent unnecessary use of contrast medium and improve the effect of contrast enhancement.

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

A Study for the Methodology of Analyzing the Operation Behavior of Thermal Energy Grids with Connecting Operation (열 에너지 그리드 연계운전의 운전 거동 특성 분석을 위한 방법론에 관한 연구)

  • Im, Yong Hoon;Lee, Jae Yong;Chung, Mo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.143-150
    • /
    • 2012
  • A simulation methodology and corresponding program based on it is to be discussed for analyzing the effects of the networking operation of existing DHC system in connection with CHP system on-site. The practical simulation for arbitrary areas with various building compositions is carried out for the analysis of operational features in both systems, and the various aspects of thermal energy grids with connecting operation are highlighted through the detailed assessment of predicted results. The intrinsic operational features of CHP prime movers, gas engine, gas turbine etc., are effectively implemented by realizing the performance data, i.e. actual operation efficiency in the full and part loads range. For the sake of simplicity, a simple mathematical correlation model is proposed for simulating various aspects of change effectively on the existing DHC system side due to the connecting operation, instead of performing cycle simulations separately. The empirical correlations are developed using the hourly based annual operation data for a branch of the Korean District Heating Corporation (KDHC) and are implicit in relation between main operation parameters such as fuel consumption by use, heat and power production. In the simulation, a variety of system configurations are able to be considered according to any combination of the probable CHP prime-movers, absorption or turbo type cooling chillers of every kind and capacity. From the analysis of the thermal network operation simulations, it is found that the newly proposed methodology of mathematical correlation for modelling of the existing DHC system functions effectively in reflecting the operational variations due to thermal energy grids with connecting operation. The effects of intrinsic features of CHP prime-movers, e.g. the different ratio of heat and power production, various combinations of different types of chillers (i.e. absorption and turbo types) on the overall system operation are discussed in detail with the consideration of operation schemes and corresponding simulation algorithms.

A study on inspection methods for waste treatment facilities(II): Derivation of problems and improvement direction in inspection methods (폐기물처리시설의 세부검사방법 마련연구(II): 세부검사방법 문제점도출 및 개선방향 설정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.85-100
    • /
    • 2023
  • In this study, in order to improve the installation periodical inspection method of waste treatment facilities, we conducted on-site surveys of waste treatment facilities classified into six fields, grasped the problems of inspection methods, and made improvements accordingly. And revised the inspection method for waste treatment facilities. As a result, in the field of incineration and incineration heat recovery, inspection methods such as total temperature measurement and one-year TMS data comparison using a thermal imaging camera were established. And for the safety of the inspected person, it was applied so that the waste can be replaced with a document without opening it. In the case of landfill facilities, the details regarding the use of video information processing equipment and the management of facilities covering the upper part of the landfill facility are presented in the law, but the items that do not have a inspection methods were applied to the inspection method. In the case of Food Waste Treatment Facility, inspection methods were put in place to ensure compliance with standards for foul-smelling fish in odor control, a major cause of complaints. As a result, 10 out of 18 improvement proposals were reflected in the incineration and sterilization grinding, cement kiln, and incineration heat recovery facilities, and 11 out of 12 improvement proposals were reflected in the landfill facility. In the case of food distribution waste treatment facilities, 10 out of 12 improvement proposals were reflected, and a total of 31 inspection methods were improved.

Effect of Halal and Conventional Slaughtering Method with CO2 and N2 Gas Stunning on Physicochemical Traits of Chicken Breast Muscle and Small Intestine (도계 중 할랄방법에 CO2와 N2 가스기절처리가 닭 가슴살과 내장의 물리화학적 특성에 미치는 영향)

  • Song, Dong-Heon;Alam, Shahbubul Muhammad;Lee, Jeong-Ah;Hoa, Van Ba;Kang, Sun Moon;Kim, Hyoun Wook;Jeon, JinJoo;Kang, Hwan Ku;Cho, Soo-Hyun;Seol, Kuk-Hwan
    • Korean Journal of Poultry Science
    • /
    • v.49 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • We investigated the effects of stunning methods and gas treatments during slaughter on the quality characteristics of chicken breast and small intestine. Broilers (Ross 308) were stunned and slaughtered using halal, CO2, or N2 gas stunning methods (for 10 birds). After slaughter, the pH, proximate composition, color, water-holding capacity, cooking loss, and shear force of chicken breast muscle and small intestine were determined. Compared with the halal treatment, CO2 treatment resulted in higher pH and lower cooking loss (P<0.05), and the pH, color, and shear force of chicken breast muscle with N2 treatment were similar to those of the halal treatment (P>0.05). Compared with the halal treatment, the gas treatments resulted in lower pH and lightness and higher redness, yellowness, thickness, and shear force of the small intestine (P<0.05). However, compared with the CO2 treatment, the N2 treatment resulted in lower pH, redness, and yellowness, and higher lightness, thickness, and shear force. Overall, compared with the halal method, our results suggest that the use of N2 gas suppresses the discoloration and deterioration of the texture of chicken meat and small intestine caused by CO2 gas treatment in the gas stunning method.

Studies on the Processing of Chestnut (Castanea pubinervis Schneid) Part 1. Trials on the Raw Material Adaptability for Processing and Colored Products Development (밤(Castanea pubinervis schneid) 가공(加工)에 관(關)한 연구(硏究) 제1보 밤의 가공(加工) 적성(適性) 및 유색(有色) 가공품(加工品) 개발(開發)을 중심(中心)으로)

  • Suh, K.S.;Han, P.J.;Lee, S.J.
    • Korean Journal of Food Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.98-108
    • /
    • 1974
  • Fourteen varieties of Korean chestnut were subjected to the test of adaptability for processing and the possibilities of colored products development. The fruit size of Korean chestnut ranged $11{\sim}18g$ and these small fruits could not be expected to be utilized for the processing of Marron glaces which requires larger size as $25{\sim}30g$. As the storge period is extended the discoloration tendency of chestnut flesh was increasingly developed, however, the fresh chestnut has shown layer-separating phenomenon and ragged surface of fruit which delivers disagreeable appearance to the finished product. The principal factors of discoloration occurred during processing were the behavior of tannin and darkening rate shown on flesh differed each other among varieties; the Chukpa and Yuma variety have exhibited the most serious discoloration and the Taab-b variety, the lightest. Taab-b variety in this connection could be expected to be available for Kanroni processing. For the industrialization of chestnut processing the flame-scorched peeling method is advisable. The capacity of this method is proportional to the square of scorching radius and highly flexible in controlling its performance. As for the processing of colored product, the sugar dehydration and coating and the sugar penetration method demand further study in basical views; however, the canned product of chestnut-redbean has shown the possibility of being utilized as a substitute for or paralleled use with the sugar-syruped canned product which so far has been considered as the only item of export to Japan.

  • PDF

Comparison of Sampling Methods for On-Farm Use Quick Test Procedure of Soil Nitrate (토양의 질산태질소 현장검정을 위한 시료 채취방법 비교)

  • Kang, Seong-Soo;Kim, Ki-In;Chung, Keun-Yook;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.1
    • /
    • pp.32-37
    • /
    • 2005
  • The procedure of soil sampling for on-farm quick test of soil nitrate is very important to improve practical application without weighing or drying soil. To improve application of test strip reflectometer as a quick on-farm analytical procedure for the estimation of soil nitrate concentration, three sampling methods such as gravimetric sampling (GS), particle density sampling (PDS) and bulk density sampling (BDS) for on-farm analytical procedure were investigated with twelve soils of 45 to $281mg\;kg^{-1}$ nitrate nitrogen concentration. The nitrate nitrogen concentrations measured from different soils were compared with two analytical methods, ion electrode method as a standard laboratory analysis (SLA) and test strip reflectometer at three moisture conditions, viz. air dried soil, 20 and 40% of maximum water holding capacity (MWHC). Nitrate nitrogen concentration measured by test strip reflectometer was significantly correlated with that of SLA, and the coefficients of variation (CV) were in the range of 3.5 to 10.9%. These CV values less than 10.9% were thought to be acceptable for the measurement of soil nitrate as an on-farm real time analytical procedure. The nitrate nitrogen concentration by BDS for test strip reflectometer as well as ion electrode method was more similar to that of SLA compared with those by GS and PDS especially in case of moist soils. This result suggests that the BDS is more useful than GS and PDS in case of on-farm analytical procedure of soil nitrate for moist soils. Further the practical measurement by BDS could be improved by substituting the bottle cap with a larger container.

Growth and Physiological Characteristics of Five Common Foliage Plant Species Grown under the Influence of Static Magnetic Field (정자기장 처리에 따른 실내 관엽식물의 생육 및 생리적 특성 변화)

  • Lee, Seong Han;Woo, Su Young;Kwak, Myung Ja
    • Horticultural Science & Technology
    • /
    • v.30 no.5
    • /
    • pp.484-492
    • /
    • 2012
  • The present study aimed to investigate the effect of static magnetic field (SMF) on the growth and physiological characteristics of common indoor plant species. Five foliage plant species, Spathiphyllum spp., Ardisia pusilla DC., Syngonium podophyllum, Peperomia pereskiifolia, and Pilea cadierei were potted into plastic pot equipped with round type anisotropic sintered NdFeB permanent magnet inside the pot. The surface magnetic flux density of each magnet was 3,500 G. After 6 months of growth period, the biomass accumulations of Spathiphyllum, A. pusilla, and P. cadierei under SMF were statistically higher than those of controls. Tissue water content also increased under the influence of SMF in most species. The photosynthetic rate of Spathiphyllum under SMF significantly increased but other species showed no significant difference compared with control. Although there was no significant increase in the photosynthetic rates of A. pusilla, and P. cadierei, they showed remarkable increase in total fresh weight under SMF. This suggests that the demand of assimilates for normal metabolism could be decreased under magnetic influence and thereby biomass accumulation could be more favored. But this is not always true for all plant species because P. pereskiifolia in this experiment, showed no changes in both photosynthetic rate and biomass accumulation. Leaf nitrogen and chlorophyll contents were enhanced significantly in most plant species under influence of SMF. Chlorophyll a/b ratio also increased by SMF. Although there might be a limitation depending on plant species, these results suggest that long-term exposure to SMF might allow plant to have an enhanced acclimation capacity against environmental fluctuations and optimal application of SMF could increase the practical use of indoor plants such as an attempt to improve indoor air quality.

The Cesium Removal Using a Polysulfone Carrier Containing Nitric Acid-treated Bamboo Charcoal (질산으로 표면처리한 대나무 활성탄을 첨가한 폴리술폰 담체의 세슘제거 효율 규명)

  • Rahayu, Ni Wayan Sukma Taraning;Kim, Seonhee;Tak, Hyunji;Kim, Kyeongtae;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.53 no.5
    • /
    • pp.529-542
    • /
    • 2020
  • The cesium (Cs) sorption characteristics of a bead-type polysulfone carrier contained HNO3-treated bamboo charcoal (3 - 5 mm in diameter) in water system were investigated and its Cs removal efficiency as an adsorbent from water was also identified by various laboratory experiments. From the results of batch sorption experiments, the bead-type polysulfone carrier with only 5% HNO3-treated bamboo charcoal (P-5NBC) represented the high Cs removal efficiency of 57.8% for 1 hour sorption time. The Cs removal efficiency of P-5NBC in water after 24 hours reaction maintained > 69% at a wide range of pH and temperature conditions, attesting to its applicability under various water systems. Batch sorption experiments were repeated for P-5NBC coated with two cultivated microorganisms (Pseudomonas fluorescens and Bacillus drentensis), which were typical indigenous species inhabited in soil and groundwater. The Cs removal efficiency for two microorganisms coated polysulfone carrier (BP-5NBC) additionally increased by 19% and 18%, respectively, compared to that of only P-5NBC without microorganisms coated. The average Cs desorption rate of P-5NBC for 24 h was lower than 16%, showing the Cs was stably attached on HNO3-treated bamboo charcoal in so much as its long-term use. The maximum Cs sorption capacity (qm) of P-5NBC calculated from the Langmuir isotherm model study was 60.9 mg/g, which was much higher than those of other adsorbents from previous studies for 1 h sorption time. The results of continuous column experiments showed that the P-5NBC coated with microorganisms packed in the column maintained > 80% of the Cs removal efficiency during 100 pore volumes flushing. It suggested that only 14.7 g of P-5NBC (only 0.75 g of HNO3 treated bamboo charcoal included) can successfully clean-up 7.2 L of Cs contaminated water (the initial Cs concentration: 1 mg/L; the effluent concentration: < 0.2 mg/L). The present results suggested that the Cs contaminated water can be successfully cleaned up by using a small amount of the polysulfone carrier with HNO3-treated bamboo charcoal.

A Study on the Mineralogical Characteristics and its Agricultural Use of Barley Stone (Diabase Porphyrite) (맥반석(麥飯石)(휘록분암)에 대(對)한 광물학적(鑛物學的) 특성(特性)과 농업적(農業的) 활용(活用) 가능성(可能性)에 관(關)한 연구(硏究))

  • Choi, Dae-Ung;Jung, Pil-Kyun;Um, Ki-Tae;Park, No-Kwon;Park, Seon-Do
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.20 no.3
    • /
    • pp.199-204
    • /
    • 1987
  • This study was conducted to verify the identity and the effects on soil improvements by the application of Barley stone which has been recently named as miraculous mineral on account of being propagandized as health stone because of several special effect of medicine, the supplement of micronutrients for agriculture, prevention against diseases and insects of plant, and the increase of nutrient holding capacity of soil. The results were summarized as follows; 1. Barley stone is considered as Diabase Porphyrite by the analysis of X-ray Diffraction, chemical composition and microspore's observation. This mineral stone called as Barley stone has been deducted because of being seen as if the feature was attatched with cooked barley and appearently scattered about feldspar's phenocryst on the dark-green stone base. 2. In chemical characteristics of barley stone, the pH 8.7 was higher but C.E.C. 9.0 me/100g was lower then those of other clay minerals such as Bentonite and Zeolite, and so barley stone material was not considered suitable for improvement of sandy loam soil. 3. Effects of Bentonite and Zeolite application on yield of paddy rice were 108-109% compare to non-treated plot, but Barley stone has not increased rice yield. Notwithstanding the increase of application of barely stone to 5 ton per 10a, the yield increase was not significantly showing only 102-103% and the effects of Peanut, hot pepper and chinese cabbage were not recognized either.

  • PDF