• Title/Summary/Keyword: Capacitor design method

Search Result 247, Processing Time 0.02 seconds

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

Resonance Device Design of Bidirectional DC-DC Converter for Active Power Decoupling of Photovoltaic AC Module (태양광 AC 모듈의 능동 디커플링을 위한 양방향 DC-DC 컨버터의 공진 소자 설계)

  • Kim, Mi-Na;Noh, Yong-Su;Kim, Jun-Gu;Lee, Tae-Won;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.103-104
    • /
    • 2012
  • In the AC module system, mismatch problem between AC power and constant input power is occurred. To solve this problem, electrolytic capacitor is utilized for diminishing power pulsation in PV side. However, it has disadvantages of low life span and weak in temperature. Decoupling method has been studied to reduce the capacitance and replaces electrolytic capacitor to film capacitor. This paper proposes design method for decoupling circuit which bidirectional DC-DC converter using soft switching. Proposed system is verified by design optimization and simulation results.

  • PDF

Identification of Torque Characteristics in Capacitor Type Electric Motors and Reduction of Its Fluctuation Components (축전기형 전동기의 토크에 대한 특성분석 및 그 변동성분의 감소를 위한 연구)

  • 고홍석;신성수;김광준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.826-834
    • /
    • 1994
  • The purpose of this study is to identify torque characteristics in capacitor type electric motors and to illustrate the effects of several design parameters on the fluctuating components of the motor torque. To do this, two revolving field theory and stationary reference frame theory were applied to derive governing equations for the torque generated by motor. For simulation studies, parameters of the motor components were measured under the conditions of no loading and locking. Based on these, effects of several design variables on the torque characteristics were analyzed and compared with the actual measurements, which were estimated indirectly by measuring the stator voltage and current. Then, some illustrative improvements in design are suggested by taking Taguchi method.

Design of Input.Output Filter of Single Multifunctional UPS (단상 다기능 UPS 입.출력 필터 설계)

  • 김제홍
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

A High Aperture Ratio TFT Design for Bottom Emission Type AMOLED

  • Chien, Yao Hong;Huang, Jack
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.711-714
    • /
    • 2004
  • A new design for improving the aperture ratio of bottom emission type AMOLED is investigated. In conventional, the TFT of AMOLED fabrication method is "Etch Stopper (7-mask)", so the aperture ratio is limited in 28${\sim}$33% by Cs(Storage Capacitor). A high aperture ratio TFT is designed by using BCE(Back Channel Etching 5-mask) fabrication way and the aperture ratio is up to 40% shown in 2.2"AMOLED display.

  • PDF

A Voltage Inverter Switch With a New Clocking Scheme and its Application to Switched Capacitor Filter Design (새로운 Clocking 방식에 의한 Voltage Inverter Switch 및 Switched Capacitor Filter 설계에의 응용)

  • 이방원;박송배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.4
    • /
    • pp.1-11
    • /
    • 1981
  • This paper proposes a method of generalizing the clocking scheme in the Switched Capacitor Filter(SCF) design using Voltage Inverter Switches (VIS's). Parallel RC and RL elements, and parallel LC resonators can be implemented by the proposed clocking schemes Applying these new elements and the generalized clocking schemes to the SCF design, the total number of required operational amplifiers and capacitors can be reduced. Experimental results of a band- stop filter and a low-pass filter using a new type grounded VIS show good agreements with t he theoretical characteristics.

  • PDF

Output LC Filter Design of Single Phase Voltage Source Inverter Used for Uninterruptible Power Supply (무정전전원장치용 단상 전압형 인버터의 출력 LC필터 설계)

  • Min, Wan-Ki;Kim, Jae-Sik;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.83-89
    • /
    • 2007
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

Output LC Filter Design of Three Phase Voltage Source Inverter Considering the Performance of Controller (제어기 응답을 고려한 삼상 전압형 인버터의 출력 LC필터 설계)

  • 최재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.748-751
    • /
    • 2000
  • in this paper the design procedure of three phase voltage source inverter output filter is described. The 'd' axis transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form the capacitor value can be calculated with the system time constant is given as the closed,. form the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load is connected.

  • PDF

Design of Three-port Flyback Inverter for Active Power Decoupling (능동 전력 디커플링을 위한 3권선 방식의 플라이백 인버터 설계)

  • Kim, Kyu-Dong;Kim, Jun-Gu;Lee, Tae-Won;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.486-487
    • /
    • 2012
  • In this paper, novel three-port active power decoupling (APD) method for applying 250[W] micro-inverter. This type using third port for active power decoupling stores the surplus energy and supplies sufficient energy to grid. Conventional decoupling circuit is applied in single phase grid connected micro-inverter especially single-stage configuration like flyback-type DC-AC inverter. In this passive power decoupling method, electrolytic capacitor with large capacitance is needed for decoupling from constant DC power and instantaneous AC power. However the decoupling capacitor is replaced with film capacitor by using APD, thus the overall system can achieve smaller size and long lifespan. Proposed three-port flyback inverter is verified by design and simulation.

  • PDF

Implementation of One-Cycle Control for Switched Capacitor Converters

  • Yang, Lei;Zhang, Xiaobin;Li, Guann-pyng
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2057-2066
    • /
    • 2016
  • An extension of the one-cycle control (OCC) method for switched-capacitor (SC) converters is proposed in this paper, featuring a fast dynamic response, wide line and load operation ranges, and simplicity in implementation. To illustrate the operation principle of this nonlinear control method and to demonstrate its simplicity in design, a dual-phase unity gain SC converter is examined. A new control loop based on the charge balance in a flying capacitor is formulated for the OCC technique and implemented with a 15W dual-phase unity gain SC converter on a circuit board for control verification. The obtained experimental results show that external disturbances can be rejected in one switching cycle by the OCC controlled SC converter with good line and load regulations. When compared to other control methods, the proposed nonlinear control loop exhibits superior dynamic performance in suppressing input and load disturbances.