• 제목/요약/키워드: Capacitor current control model

검색결과 51건 처리시간 0.028초

추가적인 센서가 필요 없는 3상 PWM 인버터의 LCL 필터 능동댐핑 (Active Damping of LCL Filter for Three-phase PWM Inverter without Additional Hardware Sensors)

  • 안병웅;신희근;김학원;조관열;한병문
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.10-17
    • /
    • 2013
  • In this paper, a new active damping method of LCL filter without capacitor voltage sensors is proposed for 3 phase PWM Inverter. Normally, L filter or LCL filter is used as an output filter of grid connected PWM inverter. An LCL filter has more excellent performance than L filter to reduce harmonic current, so the small inductance value can be used. However, the resonance problem in LCL filter is happen due to the zero impedance by the addition of LC branch. To solve the resonance problem, the various active damping method has been proposed so far. Generally, the virtual resistor active damping methods is required to additional hardware sensors for measurement of capacitor voltage and current. In this paper, the new active damping method is proposed without any capacitor voltage or current sensors. In the proposed method, the resonance component of the capacitor voltage of LCL filter can be observed by a simple MRAS(Model Reference Adaptive System) observer without additional hardware sensors, and this component is suppressed by feedforward compensation. The validity of the proposed method is proven by simulation and experiment on the 3-phase PWM inverter system.

Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) for quasi Z-Source Inverters based on a Current Observer

  • Bakeer, Abualkasim;Ismeil, Mohamed A.;Orabi, Mohamed
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.610-620
    • /
    • 2017
  • The Finite Control Set-Model Predictive Controller (FCS-MPC) for quasi Z-Source Inverters (qZSIs) is designed to reduce the number of sensors by proposing a current observer for the inductor current. Unlike the traditional FCS-MPC algorithm, the proposed model removes the inductor current sensor and observes the inductor current value based on the deposited prior optimized state as well as the capacitor voltage during this state. The proposed observer has been validated versus a typical MPC. Then, a comparative study between the proposed Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) and a linear PID controller is provided under the same operating conditions. This study demonstrates that the dynamic response of the control objectives by MFCS-MPC is faster than that of the PID. On the other hand, the PID controller has a lower Total Harmonic Distortion (THD) when compared to the MFCS-MPC at the same average switching. Experimental results validate both methods using a DSP F28335.

멀티레벨 전압형 인버터를 사용한 무효전력보상장치

  • 민완기;김병철;전형석;김형곤;신석두;장성남;이광석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.21-25
    • /
    • 1999
  • This paper proposes a novel control strategy of SVC(Static var compensator) using cascade multilevel inverter. To control the reactive power instantaneously, the dq-dynamic system model is described and analyzed. A single pulse pattern based on the SHE(Selective Harmonic Elimination) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is applied to adjust the DC capacitor voltage at the scheme level. From the simulation, it is verified that this proposed control scheme make the dynamic control response of SVC fast, the current harmonics low, and the DC capacitor voltage balanced.

  • PDF

풀 브리지 인버터 기반 단상 유도전동기의 소프트 기동 기법 (Soft Start-up Algorithm of Single-Phase Induction Motor Based on Full-bridge Inverter)

  • 김태성;강형도;황선환
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.258-265
    • /
    • 2018
  • 본 논문은 단상 유도전동기의 기동 시 발생하는 기동전류를 분석하고 이를 저감하기 위한 알고리즘을 제안한다. 일반적으로 단상 유도전동기는 구조적인 특성으로 인해 기동토크를 발생시킬 수 있는 별도의 기동장치가 요구된다. 본 논문에서 사용되고 있는 방법은 커패시터-기동/커패시터-운전 방식이며 타 방식 대비 기동토크가 크고 운전효율이 높은 특성이 있다. 하지만 초기 기동 시 약 5~6배에 해당되는 돌입전류가 발생하며 이로 인한 초저온 냉동고 기동 소자와 주변기기들의 소손 및 수명 저하의 원인이 된다. 기동 시 발생하는 돌입전류를 저감하기 위하여 가상 dq모델 기반의 전류제어 알고리즘을 적용하여 기동 전류를 제한하고, 정격운전에 도달 시 상용전원과 동일한 운전조건으로 전환하기 위한 알고리즘을 실험을 통하여 그 타당성을 검증한다.

A Study on the Torque Performance to Capacitance of a Capacitor-run type Single Phase Induction Motor

  • Kim Cherl-Jin;Choi Chul-Yong;Baek Soo-Hyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.20-26
    • /
    • 2005
  • Various kinds of practical machines using the single phase induction motor (SPIM) are utilized to control both speed and torque. In particular, the capacitor-run type SPIM has the characteristic that allows the motor torque to be altered by auxiliary capacitance variation. In this study, we manifest an equivalent model having a more simplified configuration, and clarify the relationship between torque and capacitance. Also, we design an experimental controller that is able to perform speed control with ease by the phase angle control of the AC input voltage. Validity of this study is confirmed through the simulation and experimental results obtained.

Crowbar 운전을 가지는 이중여자유도발전기 풍력발전시스템의 제어전략 (Control Strategies of Doubly Fed Induction Generator -Based Wind Turbines with Crowbar Activation)

  • 저스토 잭슨 존;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.706-707
    • /
    • 2011
  • The insertion of the crowbar system in the doubly fed induction generator rotor circuit for a short period of time during grid disturbance enables a more efficient way of limiting transient rotor current and hence protecting the rotor side converter (RSC) and the DC - link capacitor. When crowbar is activated at fault occurrence and clearance time, RSC is blocked while DC -link capacitor and the grid side converter (GSC) can be controlled to provide reactive power support at the PCC and improve the voltage which helps to comply with grid codes. In this paper, control strategies for crowbar system to limit the rotor current during fault is presented with RSC and GSC controllers are modified to control PCC voltage during disturbance to enhance DFIG wind farm to comply with some strict grid codes. Model simulated on MATLAB/Simulink verify the study through simulation results presented.

  • PDF

연산지연시간과 파라미터 변동에 강인한 UPS 인버터의 내부모델제어 (Internal Model Control of UPS Inverter with Robustness of Calculation Time Delay and Parameter Variation)

  • 박지호;계중읍;김동완;안영주;박한석;우정인
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.175-185
    • /
    • 2002
  • In this paper, a new fully digital current control method of UPS inverter, which is based on an internal model control, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The internal model controller is adopted to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. That is, the average current of filter capacitor is been exactly equal to the reference current with a time lag of two sampling intervals. Therefore, this method has an essentially overshoot free reference-to-output response with a minimum possible rise time. The effectiveness of the proposed control system has been verified by the simulation and experimental respectively. From the simulation and experimental results, the proposed system is achieved the robust characteristics to the calculation time delay and parameter variation as well as very fast dynamic performance, thus it can be effectively applied to the power supply for the critical load.

Design Methodology of a Three-Phase Dual Active Bridge Converter for Low Voltage Direct Current Applications

  • Lee, Won-Bin;Choi, Hyun-Jun;Cho, Young-Pyo;Ryu, Myung-Hyo;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.482-491
    • /
    • 2018
  • The practical design methodology of a three-phase dual active bridge (3ph-DAB) converter applied to low voltage direct current (LVDC) applications is proposed by using a mathematical model based on the steady-state operation. An analysis of the small-signal model (SSM) is important for the design of a proper controller to improve the stability and dynamics of the converter. The proposed lead-lag controller for the 3ph-DAB converter is designed with a simplified SSM analysis including an equivalent series resistor (ESR) for the output capacitor. The proposed controller can compensate the effects of the ESR zero of the output capacitor in the control-to-output voltage transfer function that can cause high-frequency noises. In addition, the performance of the power converter can be improved by using a controller designed by a SSM analysis without additional cost. The accuracy of the simplified SSM including the ESR zero of the output capacitor is verified by simulation software (PSIM). The design methodology of the 3ph-DAB converter and the performance of the proposed controller are verified by experimental results obtained with a 5-kW prototype 3ph-DAB converter.

Active Damping Method Using Grid-Side Current Feedback for Active Power Filters with LCL Filters

  • Tang, Shiying;Peng, Li;Kang, Yong
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.311-318
    • /
    • 2011
  • LCL filters installed at converter outputs offer a higher harmonic attenuation than L filters. However, as a three order resonant circuit, it is difficult to stabilize and has a risk of oscillating with the power grid. Therefore, careful design is required to damp LCL resonance. Compared to a passive damping method, an active damping method is a more attractive solution for this problem, since it avoids extra power losses. In this paper, the damping capabilities of capacitor current, capacitor voltage, and grid-side current feedback methods, are analyzed under the discrete-time state-space model. Theoretical analysis shows that the grid-side current feedback method is more suitable for use in active power filters, because it can damp LCL resonance more effectively than the other two methods when the ratio of the resonance and the control frequency is between 0.225 and 0.325. Furthermore, since there is no need for extra sensors for additional states measurements, this method provides a cost-efficient solution. To support the theoretical analysis, the proposed method is tested on a 7-kVA single-phase shunt active power filter.

Four Quadrant CMOS Current Differentiated Circuit

  • Parnklang, Jirawath;Manasaprom, Ampaul;Ukritnukul, Anek
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.948-950
    • /
    • 2003
  • In this literature, the CMOS current mode fout quadrant differentiator circuit is proposed. The implementation is base on an appropriate input stage that converts the input current into a compressed voltage at the input capacitor ($C_{gs}$) of the CMOS driver circuit. This input voltage use as the control output current which flow to the output node by passing through a MOS active load and use it as the feedback voltage to the input node. Simulation results with level 49 CMOS model of MOSIS are given to demonstrate the correct operation of the proposed configuration. But the gain of the circuit is too low so the output differentiate current also low. The proposed differentiator is expected to find several applications in analog signal processing system.

  • PDF