• 제목/요약/키워드: Capacitor Bank

검색결과 117건 처리시간 0.025초

진공 스위치를 이용한 Crowbar 시스템의 개발 (Development of the Crowbar System Using a Vacuum Switch)

  • 이태호;허창수;이홍식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권12호
    • /
    • pp.584-590
    • /
    • 2002
  • Crowbar system is usually applied to a pulsed power system in which a capacitor bank is discharged into a load. This provides a free wheeling path for the load current and prevents the capacitor from recharging due to a reverse voltage. Usually diodes have been used as a crowbar switch, but it is not a practical system because the cost of the diodes goes up enormously with increasing the system voltage and current. This paper presents a novel protection scheme of a charging and discharging system of a 300 kJ capacitor bank using a low-cost crowbar system which consists of a crowbar switch and resistors. Triggered vacuum switch(TVS) was used for a crowbar switch, and Rogowski coil was used to determine a trigger time of TVS. When this crowbar system is applied to our pulsed power system which consists of capacitor bank($123muF$), inductor() for forming a pulse, load resistor$(100 m\Omega)$, and a closing switch, instantaneous reversal voltage of capacitor bank could be limited less than 1.8 ㎸ until capacitor bank was charred to 17 ㎸.

하이브리드 타입 커패시터 뱅크를 이용한 공급신뢰도 및 전력품질 개선 방안 연구 (A Study on the Service Reliability and Power Quality Improvement Using Hybrid Type Capacitor Bank)

  • 이한상;윤동희
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.313-319
    • /
    • 2014
  • 전력계통운영의 목표는 전력시스템의 안정성과 신뢰성을 유지하여 원활한 전력을 공급하는 것이다. 안정적인 전력 공급을 위하여 무효전력과 모선 전압에 대한 고려를 해야 하는데, 모선의 전압을 일정 범위 이내로 유지하기 위하여 커패시터 뱅크를 비롯한 다양한 방안이 사용되고 있다. 본 논문에서는 계통 안정도와 전력공급 신뢰도를 상시키기 위한 하이브리드 타입의 커패시터 뱅크 설계 과정에 대하여 기술하였다. 설계 과정에는 커패시터 뱅크의 용량 산정, 리액터 타입 결정 및 리액터 용량 산정과정이 포함된다. 기존의 커패시터 뱅크의 설계과정과 같이 정상상태 Q-V 해석이나 상정사고 분석과 같은 방법을 통하여 무효전력 마진을 계산하여 저전압이 발생하는 모선에 무효전력 보상량을 산정한다. 그리고 고조파 실측을 통해 산출된 개별 고조파의 성분 크기를 기반으로 직렬 리액터의 크기를 산정하는 방식으로 설계과정을 제안하였다. 논문에서는 제안된 방법을 통하여 고조파의 크기가 감소함을 증명하였으며, 특히 5차와 7차 고조파의 저감에 효율적임을 보여주었다.

하이브리드 방식에 의한 미시적 부하모델링 (Component-Based Load Modeling Updated by Hybrid Technique)

  • 지평식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.179-182
    • /
    • 2003
  • Component-based method for load model not only should include the performances of the load components, but also should take into consideration the core losses of transformers, the line losses and the capacitor banks. Especially, capacitor bank affects the accuracy of reactive load model in load modeling. But it is difficult to identify actual reactive powers of capacitor banks in power system for load modeling. This research improves the component-based modeling method including uncertain capacitor bank. The proposed method is hybrid technique, which adds the measurement-based method to the existing component-based method for reliable information of capacitor band. The results of case studies were presented to verify the validity of the proposed method.

전계해석을 이용한 고전압 커패시터 뱅크의 쉴드 설계 (Design of Shield for Capacitor Bank Using Electric Field Analysis)

  • 정진교;이우영;박경엽;윤자홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1115-1117
    • /
    • 2004
  • When high voltage capacitor bank is constructed, Many problems occur because of corona. So, To decrease a effect of electric field is usually installed a shield. This paper shows the results of design of shield for high voltage capacitor bank.

  • PDF

진상소전류시험용 Capacitor Load Bank 설계 (Design of Capacitor Load Bank for Capacitive Current Switching Tests)

  • 노창일;나대열;김선구;정흥수;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.106-108
    • /
    • 2002
  • Capacitive current switching test for circuit breaker and load breaker switch requires special attention because, after current interruption, the capacitive load contains an electrical charge and can cause dielectric restrike and re-ignition of the switching devices. therefore dielectric strength of capacitor load bank shall be able to withstand 4Vt (Vt : test voltage) and charging voltage discharged within 1 min. In this paper presents both characteristic of capacitive current switching tests and design of capacitor load bank.

  • PDF

커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로 (Low-cost crowbar system and protection scheme in capacitor bank module)

  • 임근희;조주현;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

PRT 차량의 전력 공급시스템 개발 (A Development of the Electric Power Supply System for PRT Vehicle)

  • 김백현;정락교;정상기;강석원
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.196-200
    • /
    • 2013
  • In this paper, the design of PRT vehicle power supply system is discussed. Since there is no power feeding line facilities in PRT system under development, the PRT vehicle must have its own energy storage device on board. For the energy storage device, ultra-capacitor bank is applied due to its fast charging capability and long life time. Charging the Ultra-capacitor bank is performed by wireless inductive power transfer system. The capacitor bank is charged up in less than 10 seconds when the vehicle is traveling by passenger stations. In this paper the design of the ultra-capacitor bank and the wireless inductive power transfer system for the PRT vehicle are discussed. Tests are conducted for the both system and the result shows the efficiency of the wireless inductive power transfer system is higher than 80%.

대전력 시험소의 부하시험용 콘덴서 뱅크의 최적 설계 및 EMTP 해석 (Optimized Capacitor Bank Design for Capacitive Current Test for High Power Laboratory and Analysis with EMTP Simulation)

  • 안상호;이희철;함길호;김환기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1220-1223
    • /
    • 1998
  • High Power Laboratory is the facility for building to simulate the various phenomena generated from electric systems of the real world and to test making and breaking capability, switching capability and durability of circuit breaker, switchgear and other electric utilities, moreover, load equipments which contain capacitor bank is installed for studying the diverse effects originated from the constituent of load through entire systems or receiving end. Such factors, abnormal voltage or current, can be serious in electrical systems, especially, in the case caused by capacitive components such as overvoltage or inrushcurrent, the problems may be more fatal to the systems. In this paper, the optimal design of capacitor bank which will be equipped in High Power Laboratory, which is for simulating as closely as the practical phenomena resulted from the capacitive currents, and the verification aided by computer simulations are presented. For this, analysis of the circuit characteristics according to the standards which can be criteria of the capacitive current tests and the test circuit configuration in accordance with the analysis are proposed in prelude. In the body of the paper the optimal design of capacitor bank has been obtained on the basis of all conditions mentioned above and the test circuit configuration with LGIS test requirements. furthermore, analysis and verification for the design are derived by EMTP. finally, evaluation for the capacitor bank design and further study plan are concluded.

  • PDF

N개 모듈로 구성된 커패시터 뱅크의 써지전압 발생 원인 분석 및 억제 대책 (Analysis on Surge generated in N Module Paralleled Capacitor Bank and Countermeasure for Suppression)

  • 김진성;최영호;정재원;추증호;성기열;진윤식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1597-1599
    • /
    • 2001
  • In this paper, two types of surge voltage generated in the only operation of capacitor bank composed of paralleled multi-modules are analyzed and also studied to suppress those. The surge voltage can give malfuction to the operation of capacitor bank and destroy the expensive components at the worst. The conditions and causes of surge voltage generation and the countermeasure for suppression are presented.

  • PDF

분산전원을 포함한 배전계통에서 설치비용과 유지보수 비용을 고려한 병렬 캐패시터-리액터 Bank의 최적 설치 위치 선정 (Optimal Allocation of Shunt Capacitor-Reactor Bank in Distribution System with Dispersed Generators Considering Installation and Maintenance Cost)

  • 허재행;류재근;이우리;박종영;박종근
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1511-1519
    • /
    • 2013
  • This paper proposes the allocation method for capacitor-reactor banks in a distribution system with dispersed generators to reduce the installation costs, the maintenance costs and minimize the loss of electrical energy. The expected lifetime and maintenance period of devices with moving parts depends on the total number of operations, which affects the replacement and maintenance period for aging equipment under a limited budget. In this paper, the expected device lifetimes and the maintenance period are included in the formulation, and the optimal operation status of the devices is determined using a genetic algorithm. The optimal numbers and locations for capacitor-reactor banks are determined based on the optimal operation status. Simulation results in a 69-bus distribution system with the dispersed generator show that the proposed technique performs better than conventional methods.