• 제목/요약/키워드: Capacitance monitoring

검색결과 76건 처리시간 0.031초

Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발 (A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication)

  • 김동준;손진근;전희종
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

Zigbee통신을 이용한 전력변환기기의 DC Bus 커패시터의 온라인 원격 고장진단 시스템 (On-line Remote Diagnosis System for DC Bus Capacitor of Power Converters Using Zigbee Communication)

  • 정완섭;손진근
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.29-34
    • /
    • 2015
  • DC bus electrolytic capacitors are used in variety of equipments as smoothing element of the power converters because it has high capacitance for its size and low price. It is responsible for frequent breakdowns of many static converters and inverter drive systems. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure of power converter. In this paper, the on-line remote diagnosis monitoring system for DC BUS electrolytic capacitors of power converter using low-cost type Zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using AC coupling method of DC link ripple voltage/current. The Zigbee communication-based experimental results show that the proposed remote DC capacitor diagnosis monitoring system can be applied to DC/DC converter and UPS successfully.

윤활유 물성 측정을 위한 유전상수 센서 개발 (Development of Dielectric Constant Sensor for Measurementof Lubricant Properties)

  • 홍성호;강문식
    • Tribology and Lubricants
    • /
    • 제37권6호
    • /
    • pp.203-207
    • /
    • 2021
  • This study presents the development of dielectric constant sensors to measure lubricant properties. The lubricant oil sensor is used to measure oil properties and machine conditions. Various condition monitoring methods are applied to diagnose machine conditions. Machine condition monitoring using oil sensors has advantage over other machine condition monitoring methods. The fault conditions can be noticed at the early stages by the detection of wear particles using oil sensors. Therefore, it provides an early warning in the failure procedure. A variety of oil sensors are applied to check the machine condition. Among all oil sensors, only one sensor can measure the tendency of several properties such as acidity and water content. A dielectric constant sensor is also used to measure various oil properties; therefore, it is very useful. The dielectric constant is the ratio of the capacitance of a capacitor using that material as a dielectric to that of a similar capacitor using vacuum as its dielectric. The dielectric constant has an effect on water content, contaminants, base oil, additive, and so forth. In this study, the dielectric constant sensor is fabricated using MEMS process. In the fabrication process, the shape, gap of the electrode array, and thickness of the insulation material are considered to improve the sensitivity of the sensor.

Flexible wireless pressure sensor module

  • Shin Kyu-Ho;Moon Chang-Ryoul;Lee Tae-Hee;Lim Chang-Hyun;Kim Young-Jun
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2004년도 추계 기술심포지움 초록집
    • /
    • pp.3-4
    • /
    • 2004
  • A flexible Packaging scheme, which embedded chip packaging, has been developed using a thinned silicon chip. Mechanical characteristics of thinned silicon chips are examined by bending test and finite element analysis. Thinned silicon chips ($t<50{\mu}m$) are fabricated by chemical etching process to avoid possible surface damages on them. These technologies can be use for a real-time monitoring of blood pressure. Our research targets are implantable blood pressure sensor and its telemetric measurement. By winding round the coronary arteries, we can measure the blood pressure by capacitance variation of blood vessel.

  • PDF

시간 영역 반사법에 의한 암반 변위의 계측 기술 분석 (Analysis of the Time Domain Reflectometry for the Monitoring of Rock Displacement)

  • 정소걸
    • 터널과지하공간
    • /
    • 제5권1호
    • /
    • pp.70-76
    • /
    • 1995
  • Two types of deformations can occur on the cable during the monitoring of the rock displacement by the time domain reflectometry. One is the impedance model for tensile deformation, and the other is the capacitance model for the shear deformation. The former gives a response signal with a gradual change in the amplitude of the reflected voltage, meanwhile the latter produces a signal with a blunted spike. The resolution of the TDR can be improved to 0.125% using calibration crimps on the cable of 60 meters long. It is recommended that the diameter of the cable should be 18 mm at least in order to induce a better reflected pulse without any open-circuit. The actual TDR technique cannot characterize the type and the magnitude of rock displacement quantitatively. Systematic investigation of the TDR parameters, such as the exact of cable diameter, cable length, number of crimps, combination of shearing and extension, and environment of the TDR equipment, will be able to improve the resolution to 0.01 mm.

  • PDF

TPMS 적용을 위한 가변 정전 용량형 압력센서 개발 (The development of a variable capacitive pressure sensor for TPMS(tire pressure monitoring system))

  • 최범규;김도형;오재근
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.265-271
    • /
    • 2005
  • In this study, a variable capacitive pressure sensor is fabricated for TPMS (Tire Pressure Monitoring System). This study is for developing sensors which consecutively measure the tire pressure given as 30 psi from the industrial standard. For improving non-linearity of the prior capacitive pressure sensors, it is suggested that touch mode capacitive pressure sensor be applied. In addition, initial capacitance is designed as small as possible for the conformity to the wireless sensor. ANSYS, commercial FEA package, is used for designing and simulating the sensor. The device is progressed by MEMS (Micro Electro Mechanical Systems) fabrication and packaged with PDMS. The result is obtained sensitivity, 1 pF/psi, through a pressure test. The simulation result is discrepant from experiment one. Wafer's uniformity is presumed as the main reason of discrepancy.

전기용량 센서를 이용한 가속 열 열화 변압기의 온라인 상태진단 (On-line Condition Monitoring of Thermal Accelerating Aged Transformer by Capacitive Sensor)

  • 김주한;한상옥;이세현;김한준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.82-84
    • /
    • 2005
  • In a transformer, thermal stress is the most influential parameter affecting the aging behavior of insulation system. The aging behavior of insulation system in transformer is determined mainly by the thermal conditions inside the transformer. The thermal stress on the insulation system may occur from operation in a high temperature caused by overloading or local overheating. Thus, this paper investigated the condition monitoring of insulation condition in thermally accelerated aged transformer oils by in-situ sensor. The condition of aged samples was investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. Results from the experiments are presented in this paper.

  • PDF

A critical comparison of reflectometry methods for location of wiring faults

  • Furse, Cynthia;Chung, You Chung;Lo, Chet;Pendayala, Praveen
    • Smart Structures and Systems
    • /
    • 제2권1호
    • /
    • pp.25-46
    • /
    • 2006
  • Aging wiring in buildings, aircraft and transportation systems, consumer products, industrial machinery, etc. is among the most significant potential causes of catastrophic failure and maintenance cost in these structures. Smart wire health monitoring can therefore have a substantial impact on the overall health monitoring of the system. Reflectometry is commonly used for locating faults on wire and cables. This paper compares Time domain reflectometry (TDR), frequency domain reflectometry (FDR), mixed signal reflectometry (MSR), sequence time domain reflectometry (STDR), spread spectrum time domain reflectometry (SSTDR) and capacitance sensors in terms of their accuracy, convenience, cost, size, and ease of use. Advantages and limitations of each method are outlined and evaluated for several types of aircraft cables. The results in this paper can be extrapolated to other types of wire and cable systems.

FEA 시뮬레이션을 이용한 혈관 상태 측정용 커패시티브 센서 설계; 체내 동맥 혈관 변화 모니터링이 가능한 이식형 텔레메트리 시스템 개발을 위한 (Design of Capacitive Sensors for Blood Vessel Condition Using FEA Simulation; For Developing of an Implantable Telemetry System to Monitoring the Arterial Change)

  • 강소명;이재호;웨이췬
    • 한국멀티미디어학회논문지
    • /
    • 제22권11호
    • /
    • pp.1280-1287
    • /
    • 2019
  • For developing a wireless implantable device to monitoring the artery variation in real-time. The concept of a special vessel variation measurement capacitive sensor is presented in this paper. The sensor consists of two part; main sensor to measuring the arterial variation, and reference sensor is used to improve the accuracy of the capacitance value variation. Before sensor manufacture, a model of the sensor attached on the artery was designed in 3D to conduct in the FEA simulation to validate the validity and feasibility of the idea. The artery model was designed as layered structures and made of collagenous soft tissues with intima inside, followed by the media and the adventitia. Also, a grease layer was designed in the inner of the arterial wall to imitate the clogged arteries. The simulation was divided into two parts; sensor performance test by changing the diameter of the grease layer, and arterial wall tension test by changing the blood pressure. As the simulation results, the capacitance value measured by the proposed sensor is decreased follow the diameter of the grease increased. Also, large elastic deformation of the arterial wall since changing the blood pressure has been observed.

동축 케이블을 이용한 시간영역 반사법의 암반변위 계측에의 적용 (Application of Time Domain Reflectometry to the Monitoring or Rock Mass Deformation with Coaxial Cable)

  • 정슬람;정소걸;정현기;박철환;박철환;이희근
    • 터널과지하공간
    • /
    • 제6권4호
    • /
    • pp.306-315
    • /
    • 1996
  • This paper presents an application of the TDR(Time Domain Reflectometry) to the monitoring of the deformation of rock mass with grouted coaxial cables through laboratory tests. The grouted cable can easily deform together with the rock mass movements, and the deformed cable loses its original capacitance and the reflected waveform produced along the deformed cable consequently represents a change of voltage pulse. Therefore, it is possible to monitor the deformation of rock mass by measuring the changes in these reflection signatures. Shear test of the cemented mortar containing a specimen of coaxial cable showed that the shear deformation correlated linearly with the reflection coefficient, so the TDR was effective to monitor the displacement of the rock mass. Bending test were carried out in order to determine the influence of the crooked cables on the monitoring of rock mass movements. Controlled cirmping and shearing test upon a cable of 50 m long, 12.7 mm diameter showed not only the fact that the reflection amplitudes decreased as the cable length increased but also the proper crimping depth, width and interval between two adjacent crimps. Two coaxial cables-one 100 m long and other 175m long-were installed and grouted into the separate boreholes drilled in a sedimentary formation. The behavior of the cable was monitored with metallic TDR cable tester to measure rock mass deformation based on the interpretative techniques developed through laboratory tests.

  • PDF