• Title/Summary/Keyword: Cap Separation

Search Result 21, Processing Time 0.022 seconds

Design and Evaluation of Opening Devices of Separable Nose Cap (노즈캡 분리장치 성능 연구)

  • Kang, ChoonGil;Lee, DongMin;Park, GeunSoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.101-108
    • /
    • 2015
  • In this paper, we have proposed a separable nose cap and its opening device to protect a seeker's window from aerodynamic heating and to decrease the drag force on missile body. The nose cap should be promptly deployed to secure the view field of seeker when it is needed. This cap consists of two nose cap structures and separation devices such as pyro puller and pusher. The performance of pyro puller was fully verified through analyses and several kinds of operating tests. We can obtain a sufficient confidence level of the pyro puller through many operating tests under various environments.

Performance Characteristics Due to the Inflow Distortion near Hub in an Axial Flow Fan (축류 송풍기 허브측 불균일 유입유동 현상 및 성능 특성)

  • Jang, Choon-Man;Choi, Seung-Man;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.663-669
    • /
    • 2005
  • Performance characteristics of an axial flow fan having distorted inlet flow have been investigated using numerical analysis as well as experiment. Two kinds of hub-cap, round shape and right-angled front shape, are tested to investigate the effect of inlet flow distortion on the fan performance. In case of right-angled front shape, axisymmetric distorted inflow is induced by flow separation at the sharp edge of hub-cap, and the characteristics of the inflow depends on the distance between hub-cap and blade leading edge. Flow analysis of the blade passage is peformed by solving the three-dimensional Reynolds-averaged Navier-Stokes equations. numerical solutions are validated in comparison with experimental data measured by a five-hole probe downstream of the fan rotor. It is found from the numerical results that non-uniform axial inlet velocity profile near the hub results in the change of inlet flowangle. The changed inlet flow angle near the hub invokesa flow separation on the blade surfaces, thus deteriorating the fan efficiency. The effect of the distance between hub-cap and blade leading edge on the efficiency is also discussed.

  • PDF

Studies on the Development of Sustained Release Preparation (I) Preparation and Evaluation of CAP Microcapsules of Sodium Ascorbate (지속성 제제의 개발에 관한 연구 (I) 아스코르빈산 나트륨의 CAP 마이크로캅셀의 제조 및 평가)

  • Shin, Sang-Chul;Koh, Ik-Bae
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.4
    • /
    • pp.253-262
    • /
    • 1991
  • Microencapsulation of sodium ascorbate with cellulose acetate phthalate(CAP) by coacervation/ phase separation method were carried out. Various factors affecting microencapsulation, i.e., surfactant concentration. CAP concentration, stirring speed and treatment of spermaceti as a sealing agent were studied. Dissolution rate. particle size distribution, surface feature and stability test were investigated. CAP microcapsules prepared using 0.5% span 80 as a surfactant showed smooth and round surfaces. The release of sodium ascorbate was retarded by microencapsulation with CAP and by sealant treatment with spermaceti. When triturated with sodium bicarbonate, CAP microcapsules were more stable than unencapsulated sodium ascorbate under various RH conditions at $37^{\circ}C$.

  • PDF

Microencapsulation of Propranolol.HCl with Cellulose Acetate Phthalate (Propranolol.HCl의 Cellulose Acetate Phthalate Microencapsulation에 관한 연구)

  • Ku, Young-Soon;Kim, Jae-Youn
    • YAKHAK HOEJI
    • /
    • v.33 no.5
    • /
    • pp.312-318
    • /
    • 1989
  • Microcapsule of Propranolol HCl with Cellulose Acetate Phthalate (CAP) by coacervation-phase separation method was studied. Encapsulation was carried out in the CAP-liquid paraffin-acetone ethanol solvent system. The optimum weight ratio for microencapsulation in the CAP-liquid paraffin-solvent system was 1.32:89.18:9.50 or 1.65:89.42:8.93. The wall thickness of microcapsules increased according to increasing of CAP concentration, but dissolution rate decreased. The dissolution of propranolol-HCl in simulated gastric and intestinal fluid test solution was completed within 3 min., but T50% of propranolol HCl from 10.0% CAP-microcapsules were 390 min. and 210 min. respectively. The released amount from 12.5% CAP-microcapsules was 41.8% within 720 min. in simulatd gastric fluid test solution and T50% of those in simulated intestinal fluid test solution was 250 min.

  • PDF

Computational Investigation of Pintle Nozzle Flow (핀틀 노즐 유동장의 수치해석적 연구)

  • Kim, Joung-Keun;Lee, Ji-Hyung;Chang, Hong-Been
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.2
    • /
    • pp.35-41
    • /
    • 2009
  • Both the nozzle expansion ratio and the chamber pressure are simultaneously and continuously changed according to pintle movement, resulting in a different internal flow structure and flow separation characteristics. In this paper, the pintle position effect on nozzle flow structure and separation phenomena is analyzed by experimental-aided Computational Fluid Dynamic(CFD). Among the turbulent models for RANS(Reynold Averaged Navier Stokes) in Fluent, Spalart-Allmaras model is better agreement with the nozzle wall pressure distribution attained by cold-flow test than other models. And even if a conical nozzle is used, there is a shock structure similar to cap-shock pattern mainly occurred in contoured or shaped optimized nozzle because of internal shock generated from pintle tip flow separation.

Performance Characteristics of an Axial Flow Fan According to the Shape of a Hub Cap (허브 캡 형상에 따른 축류송풍기 성능특성)

  • Jang, Choon-Man;Choi, Seung-Man;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.6 s.39
    • /
    • pp.9-16
    • /
    • 2006
  • Performance characteristics of an axial flow fan having distorted inlet flow have been investigated using numerical analysis as well as experiment. Two kinds of hub-cap, rounded and right-angled front shape, are tested to investigate the effect of inlet flow distortion on the fan performance. Numerical solutions are validated in comparison with experimental data measured by a five-hole probe downstream of the fan rotor. It is found from the numerical results that non-uniform axial inlet velocity profile near the hub results in the change of inlet flow angle. Large recirculation flow upstream the fan rotor for the right-angled hub-cap induces a negative incidence, thus invokes separated flow on the blade surfaces and deteriorates the performance of fan rotor.

A Study on Separation Minima Determination based on Surveillance System Accuracy Performance (감시시스템 정확도 성능에 따른 항공기간 최소분리간격 설정에 관한 연구)

  • Lee, Hyo-Jin;Lee, Keum-Jin;Baik, Ho-Jong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.4
    • /
    • pp.14-20
    • /
    • 2012
  • A properly determined separation minima applied in Air Traffic Management(ATM) is critical for safe and efficient aircraft operations. The separation minima is primarily determined by the accuracy performance of surveillance system, and, due to the stringent aviation safety standard, the position accuracy of the surveillance system must be estimated with a high level of reliability. This study proposed a method for estimating the position accuracy of surveillance system with a relatively small amount of data by finding upper confidence limit instead of maximum likelihood values of unknown parameters. Through the proposed method, it is possible to determine a required separation minima with a more reliability in the face of data scarcity which often occurs when we implement a new surveillance system such as Automatic Dependent Surveillance-Broadcast (ADS-B).

Synthesis and Evaluation of Molecularly Imprinted Polymeric Microspheres for Chloramphenicol by Aqueous Suspension Polymerization as a High Performance Liquid Chromatography Stationary Phase

  • Zhang, Yan;Lei, Jiandu
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1839-1844
    • /
    • 2013
  • Molecularly imprinted microsphere for chloramphenicol (CAP) with high adsorption capacity and excellent selectivity is prepared by aqueous suspension polymerization, in which chloramphenicol is used as template molecule and ethyl acetate as porogen. The CAP-imprinted microspheres are used as high performance liquid chromatography (HPLC) stationary phase and packed into stainless steel column ($150mm{\times}4.6mm$ i.d.) for selective separation of chloramphenicol. HPLC analysis suggests that chloramphenicol can be distinguished from not only its structural analogs but also other broad-spectrum antibiotic such as erythromycin and tetracycline. In addition, the binding experiments of CAP-imprinted microspheres are carried out in ethanol/water (1:4, V:V), the results indicate that the maximum apparent static binding capacity of molecularly imprinted microspheres is up to 66.64 mg $g^{-1}$ according to scatchard model.

Separation Characteristics of Oxygen Isotopes with Hydrophobic PTFE Membranes (소수성 PTFE 막의 산소동위원소 분리특성)

  • 김재우;박상언;김택수;정도영;고광훈;박경배
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.154-161
    • /
    • 2003
  • We measured the permeation characteristics of water with the hydrophobic PTFE membranes dependent on water temperature to confirm the separation of oxygen isotopes using Air Gap Membrane Distillation (AGMD) and Vacuum Enhanced Membrane Distillation (VEMD). Isotopic concentrations of $H_2^{16}O$ and $H_2^{18}O$ of the permeated water vapor were measured by Diode Laser Absorption Spectroscopy. Concentrations of the heavy oxygen isotopes in the permeated water vapor were decreased. Isotope separation coefficients for the hydrophobic PTFE membranes were 1.004∼1.01 depending on the experimental conditions. We observed the effects of air in membrane pores on the oxygen isotope separation. Isotope separation coefficients for the hydrophobic PTFE membranes without air in pores are higher than those for the membrane with air in pores.

Correlation between pit formation and phase separation in thick InGaN film on a Si substrate

  • Woo, Hyeonseok;Jo, Yongcheol;Kim, Jongmin;Cho, Sangeun;Roh, Cheong Hyun;Lee, Jun Ho;Kim, Hyungsang;Hahn, Cheol-Koo;Im, Hyunsik
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1558-1563
    • /
    • 2018
  • We demonstrate improved surface pit and phase separation in thick InGaN grown on a GaN/Si (111) substrate, using plasma-assisted molecular beam epitaxy with an indium modulation technique. The formation of surface pit and compositional inhomogeneity in the InGaN epilayer are investigated using atomic force microscopy, scanning electron microscopy and temperature-dependent photoluminescence. Indium elemental mapping directly reveals that poor compositional homogeneity occurs near the pits. The indium-modulation epitaxy of InGaN minimizes the surface indium segregation, leading to the reduction in pit density and size. The phase separation in InGaN with a higher pit density is significantly suppressed, suggesting that the pit formation and the phase separation are correlated. We propose an indium migration model for the correlation between surface pit and phase separation in InGaN.