Performance Characteristics Due to the Inflow Distortion near Hub in an Axial Flow Fan

축류 송풍기 허브측 불균일 유입유동 현상 및 성능 특성

  • 장춘만 (한국건설기술연구원 화재 및 설비연구부) ;
  • 최승만 ((주)케피코 시스템 응용팀) ;
  • 김광용 (인하대학교 기계공학과)
  • Published : 2005.12.01

Abstract

Performance characteristics of an axial flow fan having distorted inlet flow have been investigated using numerical analysis as well as experiment. Two kinds of hub-cap, round shape and right-angled front shape, are tested to investigate the effect of inlet flow distortion on the fan performance. In case of right-angled front shape, axisymmetric distorted inflow is induced by flow separation at the sharp edge of hub-cap, and the characteristics of the inflow depends on the distance between hub-cap and blade leading edge. Flow analysis of the blade passage is peformed by solving the three-dimensional Reynolds-averaged Navier-Stokes equations. numerical solutions are validated in comparison with experimental data measured by a five-hole probe downstream of the fan rotor. It is found from the numerical results that non-uniform axial inlet velocity profile near the hub results in the change of inlet flowangle. The changed inlet flow angle near the hub invokesa flow separation on the blade surfaces, thus deteriorating the fan efficiency. The effect of the distance between hub-cap and blade leading edge on the efficiency is also discussed.

Keywords