• Title/Summary/Keyword: Cannulation

Search Result 115, Processing Time 0.029 seconds

Control of Femoral Cannulation with a ProGlide Pre-Closure Device during Cardiac Surgery: Is It Reliable?

  • Kim, Chang Hun;Ju, Min Ho;Lim, Mi Hee;Lee, Chee-Hoon;Je, Hyung Gon
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.179-185
    • /
    • 2021
  • Background: The use of ProGlide as a percutaneous vascular closure device in cardiac surgery remains inconclusive. This study investigated the clinical outcomes of using ProGlide in the percutaneous cannulation of femoral vessels in adult cardiac surgery. Methods: From September 2017 to July 2018, 131 consecutive patients underwent femoral vessel cannulation during cardiac surgery. The ProGlide (Abbott Vascular Inc., Santa Clara, CA, USA) with percutaneous cannulation was used in 118 patients (mean age, 55.7±15.5 years). The accessibility of femoral cannulation was evaluated through preoperative computed tomography. For cannulation, sonography was routinely used. The postoperative ankle-brachial index (ABI) was used to evaluate femoral artery stenosis. Results: Of the 118 patients, 112 (94.9%) and 6 (5.1%) underwent minimally invasive cardiac surgery and median sternotomy, respectively. Most femoral cannulations were performed on the right side (98.3%) using 15F to 19F arterial cannulas. The technical success rate of cannulation with ProGlide was 99.2%, with no delayed bleeding or cannulation site-related complications during hospitalization. During follow-up, only 1 patient showed femoral artery stenosis with claudication and was treated with interventional balloon angioplasty. The postoperative ABI revealed no significant difference in functional stenosis between the cannulation and non-cannulation sides (n=86; cannulation vs. non-cannulation, 1.2±0.1 vs. 1.1±0). Conclusion: Percutaneous femoral cannulation with ProGlide was safe and feasible in adult cardiac surgery. This technique may be a good alternative option in patients requiring femoral vessel cannulation for cardiac surgery.

Direct Axillary Arterial Cannulation Using Seldinger's Technique in Aortic Dissection

  • Do, Young-Woo;Kim, Gun-Jik;Park, Il;Cho, Joon-Yong;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.44 no.5
    • /
    • pp.338-342
    • /
    • 2011
  • Background: The axillary artery is frequently used for cardiopulmonary bypass, especially in acute aortic dissection. We have cannulated the axillary artery using a side graft or by directly using Seldinger's technique. The purpose of this study was to assess the technical problems and complications of both cannulation techniques. Materials and Methods: From January 2003 to December 2009, 53 patients underwent operations using the axillary artery for arterial cannulation. The axillary artery was cannulated with a side graft in 35 patients (side graft group) and directly using Seldinger's technique in 18 patients (direct group). Results: The results were compared between two groups, focusing on cannulation-related morbidities including neurologic morbidity. Arterial damage or dissection of the axillary artery occurred in 1 (2.9%) patient in the side graft group and in 1 (5.6%) patient in the direct group. Malperfusion and insufficient flow did not occur in either group. There were no postoperative complications related to axillary cannulation, such as brachial plexus injury, compartment syndrome, or local wound infection, in either group. Conclusion: Technical problems and complications of the axillary arterial cannulation in both techniques were rare. Direct arterial cannulation using Seldinger's technique was done safely and more simply than the previous technique. It was concluded that both axillary arterial cannulation techniques are acceptable and it remains the surgeon's preference which technique should be used.

Impact of rumen cannulation surgery on rumen microbiota composition in Hanwoo steers

  • Minseok Kim;Tansol Park;Cheolju Park;Youl-Chang Baek;Ara Cho;Han Gyu Lee;Eunju Kim;Eun-Yeong Bok;Young-Hun Jung;Tai-Young Hur;Yoon Jung Do
    • Journal of Animal Science and Technology
    • /
    • v.66 no.2
    • /
    • pp.353-365
    • /
    • 2024
  • Rumen cannulation is a surgical technique used to collect rumen contents from ruminants. However, rumen cannulation surgery may potentially impact the composition of the rumen microbiota. This study aimed to examine the longitudinal alterations in the rumen microbiota composition of Hanwoo steers after cannulation surgery. In this study, eight Hanwoo steers were used; four steers underwent rumen cannulation surgery (cannulation group), while the remaining four were left intact (control group). Rumen samples were collected from all eight steers using the stomach tubing method on the day before surgery (day 0) and on postoperative days 1, 4, 7, 10, 14, 17, 21, 24, and 28, resulting in 80 samples (10 timepoints × 8 animals). The microbiota of all 80 samples were analyzed using 16S rRNA gene amplicon sequencing with Quantitative Insights into Microbial Ecology version 2 (QIIME2). There were no significant differences (p > 0.05) in all major phyla and most major genera representing at least 0.5% of total sequences across all 80 samples between the control and cannulation groups on the preoperative and postoperative days. However, while the alpha diversity indices did not differ (p > 0.05) between the two groups on the preoperative day, they significantly differed (p < 0.05) between the two groups on the postoperative days. Further, the overall microbial distribution based on both unweighted and weighted principal coordinate analysis plots significantly differed (p < 0.05) between the two groups on both the preoperative and postoperative days. Orthogonal polynomial contrasts indicated that major genera and microbial diversity in the cannulation group decreased following surgery but returned to their initial states by postoperative day 28. In conclusion, this study demonstrates that rumen cannulation surgery affects some major taxa and microbial diversity, suggesting that the rumen cannulation method can alter the composition of rumen microbiota in Hanwoo steers.

Effects of rumen cannulation surgery on physiological parameters and rumen fluid pH in Korean native Hanwoo cattle

  • Kim, Eunju;Kim, Seong Bum;Baek, Youl Chang;Kim, Min Seok;Choe, Changyong;Yoo, Jae Gyu;Jung, Younghun;Cho, Ara;Kim, Suhee;Do, Yoon Jung
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.4
    • /
    • pp.221-228
    • /
    • 2018
  • Rumen cannulation is used for nutritional and microbiological research, clinical diagnosis, and rumen component transfaunation. However, the cannulation procedure can affect parameters such as complete blood count findings, serum chemistry, and rumen fluid pH. The objective of this study was to evaluate the health risks related to the rumen cannulation procedure over a 1-month period. We did not identify significant differences in red blood cell numbers or morphologies between pre- and postoperative timepoints. Moreover, no inflammation or infection was detected. Despite the absence of apparent clinical signs after surgery, serum chemistry results revealed changes in blood urea nitrogen levels and the activities of liver enzymes, including aspartate transaminase, lactate dehydrogenase, and creatinine kinase, from postoperative days 1 to 14. Rumen fluid pH, as measured from samples collected via an orogastric tube, was slightly increased after a preoperative fasting period and on postoperative day 1 but decreased thereafter from postoperative day 4, indicating a minor influence of cannulation surgery on ruminal fluid pH. This is the first study to evaluate hematological parameters and rumen pH before and after rumen cannulation surgery in Hanwoo cattle. Further research is required to better elucidate the potential effects of rumen cannulation surgery on animal health.

Serum and Urine Potassium Changes during, and after Extracorporeal Circulation in Open Heart Surgery (체외순환 전후의 혈청및 소변 칼륨의 변화)

  • 조창훈
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.17-22
    • /
    • 1992
  • The alterations in serum and urine potassium were studied in twenty two patients who underwent open heart surgery using extracorporeal circulation from June 1990 to August 1990 at the Department of Thoracic and Cardiovascular Surgery, School of Medicine, Kei-myung University. There were fifteen cases congenital heart disease and seven acquired heart disease. The serum and urine potassium levels were measured pre-, intra- and postoperatively until seventh postoperative day using ionic selective electrode measuring method. After general anesthesia, the serum potassium level decreased significantly but slowly increased during.cardiopulmonary bypass and returned preoperative level after operation. The urine potassium level decreased slowly from general anesthesia to cardiopulmonary bypass weaning but returned preoperative level following operation. During cardiopulmonary bypass, serum and urine potassium levels in diuretic group were lower than that of non diuretic group. There was no remarkable difference in the serum potassium level between single RA cannulation group and bicaval cannulation group preoperatively, but the serum potassium level in single RA cannulation group was much higher than that of bicaval cannulation group. There was no significant difference in the urine potassium level between single RA can-nulation group and bicaval cannulation group postoperatively.

  • PDF

Comparison of the Outcomes between Axillary and Femoral Artery Cannulation for Acute Type A Aortic Dissection

  • Lee, Hong-Kyu;Kim, Gun-Jik;Cho, Joon-Yong;Lee, Jong-Tae;Park, Il;Lee, Young-Ok
    • Journal of Chest Surgery
    • /
    • v.45 no.2
    • /
    • pp.85-90
    • /
    • 2012
  • Background: At present, many surgeons prefer axillary artery cannulation because it facilitates antegrade cerebral perfusion and may diminish the risk of cerebral embolization. However, axillary artery cannulation has not been established as a routine procedure because there is controversy about its clinical advantage. Materials and Methods: We examined 111 patients diagnosed with acute type A aortic dissection between January 2000 and December 2009. The right axillary artery was cannulated in 58 patients (group A) and the femoral artery was cannulated in 53 (group F). The postoperative outcomes were retrospectively reviewed and compared between the two groups. Results: There were 46 male and 65 female patients with a mean age of $58.9{\pm}13.1$ years (range, 26 to 84 years). The extent of aortic replacement in both groups did not differ. There were 8 early deaths (7.2%) and 2 late deaths (1.8%). The mean follow-up duration was $46.0{\pm}32.6$ months (range, 1 month to 10 years). Transient neurologic dysfunction was observed in 11 patients (19.0%) in group A and 14 patients (26.4%) in group F. A total of 11 patients (9.9%) suffered from a permanent neurologic dysfunction. Early and delayed stroke were observed in 6 patients (10.3%) and 2 patients (3.4%), respectively, in group A as well as 2 patients (3.8%) and 1 patient (1.9%), respectively, in group F. There were no statistical differences in the cannulation-related complications between both groups (3 in group A vs. 0 in group F). Conclusion: There were no differences in postoperative neurologic outcomes and cannulation-related complications according to the cannulation sites. The cannulation site in an aortic dissection should be carefully chosen on a case-by-case basis. It is important to also pay attention to the possibility of intraoperative malperfusion syndrome occurring and the subsequent need to change the cannulation site.

Simulation Study of Blood Perfusion according to Outflow Cannulation Site of Left Ventricular Assist Device (좌심실보조장치의 출구 캐뉼라의 삽관 위치에 따른 혈액관류에 대한 시뮬레이션 연구)

  • Jee, In Hyeog;Kim, Hyeong Gyun;Lim, Ki Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.135-142
    • /
    • 2015
  • Outflow cannulation site of left ventricular assist device(LVAD) chosen by considering anatomical structure of thoracic cavity and vascular system. Though outflow cannulation site influences blood perfusion at each branch, there is no standard rule or quantitative data. In this study, we computed the amount of blood perfusion at each arterial branch numerically according to outflow cannulation sites(ascending aorta, aortic arch, descending aorta). We generated computational meshes to the three-dimensionally reconstructed arterial system. Clinically measured arterial pressure were used for inlet boundary condition, porous media were applied to mimic blood flow resistance. Blood perfusion through left common carotid artery was 2.5 times higher than other cases, and that through right common carotid artery was 1.1 times higher than other branches. Although this is simulation study, will be useful reference data for the clinical study of LVAD which considers blood perfusion efficiency.

Construction of a Nomogram for Predicting Difficulty in Peripheral Intravenous Cannulation (말초 정맥주사 삽입 어려움 예측을 위한 노모그램 구축)

  • Kim, Kyeong Sug;Choi, Su Jung;Jang, Su Mi;Ahn, Hyun Ju;Na, Eun Hee;Lee, Mi Kyoung
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.30 no.1
    • /
    • pp.48-58
    • /
    • 2023
  • Purpose: The purpose of this study was to construct a nomogram for predicting difficulty in peripheral intravenous cannulation (DPIVC) for adult inpatients. Methods: This study conducted a secondary analysis of data from the intravenous cannulation cohort by intravenous specialist nurses at a tertiary hospital in Seoul. Overall, 504 patients were included; of these, 166 (32.9%) patients with failed cannulation in the first intravenous cannulation attempt were included in the case group, while the remaining 338 patients were included in the control group. The nomogram was built with the identified risk factors using a multiple logistic regression analysis. The model performance was analyzed using the Hosmer-Lemeshow test, area under the curve (AUC), and calibration plot. Results: Five factors, including vein diameter, vein visibility, chronic kidney disease, diabetes, and chemotherapy, were risk factors of DPIVC. The nomogram showed good discrimination with an AUC of 0.81 (95% confidence interval: 0.80-0.82) by the sample data and 0.79 (95% confidence interval: 0.74-0.84) by bootstrapping validation. The Hosmer-Lemeshow goodness-of-fit test showed a p-value of 0.694, and the calibration curve of the nomogram showed high coherence between the predicted and actual probabilities of DPIVC. Conclusion: This nomogram can be used in clinical practice by nurses to predict DPIVC probability. Future studies are required, including those on factors possibly affecting intravenous cannulation.

Development of Modeling System for Assessing Essential Amino Acid Requirements Using Surgically Modified Rainbow Trout (외과적 수술에 의한 송어의 혈장 아미노산 농도 측정을 이용한 아미노산 요구량 설정 모델 개발에 관한 기초연구)

  • 배승철;옥임호;박건준;김강웅;최세민
    • Journal of Aquaculture
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • A new technique combining forced-feeding and dorsal aorta cannulation was developed to monitor concentration of nutritions in the blood circulation and their metabolites in rainbow trout. To study the effect of dorsal aorta cannulation on stress, 30 rainbow trout (523$\pm$5.4 g; Mean$\pm$SD) were divided into 6 groups of 5 individuals each. A group was anesthetized and blood samples were taken at 0, 3, 6, 12, 24 or 48 h after dorsal aorta cannulation. Hematocrit peaked at 6 h and returned to 0 values by 12 h after dorsal aorta cannulation. Plasma cortisol and glucose concentrations also peaked at 6 h and returned to 0 values by 48 h after dorsal aorta cannulation. Based on the plasma cortisol and glucose concentrations, the rainbow trout recovered from the operation of dorsal aorta cannulation within 48 h. To compare the patterns of plasma free amino acid concentrations after force-feeding in the fish with dorsal aorta cannulation, 5 dorsal aorta cannulated individuals (511$\pm$6.2 g) were kept in a cage. After 48 h starvation, they were anesthetized and blood samples were taken at 0, 4, 8, 12, 24, 36 or 48 h after forced-feeding. The concentration of all plasma free amino acids, except isoleucine, leucine, phenylalanine, and tryptophan, also peaked at 4 h and returned to 0 values by 24 h after feeding. The combined technique allows forced-feeding and repeated sampling of blood in rainbow trout with minimum stress.

Studies on the Technique of Attaching Cannula after Colostomy in Chickens (닭에 있어서 결장 적출수술 후 캐뉼라를 주입시키는 인공항문 장착법에 관한 연구)

  • 손장호;남기홍
    • Korean Journal of Poultry Science
    • /
    • v.24 no.2
    • /
    • pp.91-95
    • /
    • 1997
  • This study was conducted to establish a colostomy technique using cannulation in white Leghorn male chicks. A everted rectum method was used for colostomy from 3 to 20 months old roosters. After 2 or 3 days of operation, blood clots were taken off. At this time, a cannula was also inserted into artificisal annus to keep it open. The cannula was regularly exchanged at every 7 to 10 days. Polyethylene bag and plastic beaker were used for feces and urine collection, respect-ively. The present paper describes the methods of operation, cannulation after colostomy recturn and post-operation management. This method has succeeded in colostomising chickens that survive as long as their normal counterparts.

  • PDF