Outflow cannulation site of left ventricular assist device(LVAD) chosen by considering anatomical structure of thoracic cavity and vascular system. Though outflow cannulation site influences blood perfusion at each branch, there is no standard rule or quantitative data. In this study, we computed the amount of blood perfusion at each arterial branch numerically according to outflow cannulation sites(ascending aorta, aortic arch, descending aorta). We generated computational meshes to the three-dimensionally reconstructed arterial system. Clinically measured arterial pressure were used for inlet boundary condition, porous media were applied to mimic blood flow resistance. Blood perfusion through left common carotid artery was 2.5 times higher than other cases, and that through right common carotid artery was 1.1 times higher than other branches. Although this is simulation study, will be useful reference data for the clinical study of LVAD which considers blood perfusion efficiency.
Keywords
Left Ventricular Assist Device; Cannulation Site; Porous Media;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 김은혜, 임기무, "심실의 부하감소 측면에서 좌심실 보조장치의 최적 치료시기 예측을 위한 시뮬레이션 연구", 한국기계가공학회지, vol. 12, no. 4, pp. 22-28, 2013.
2 Casarotto D., Bottio, T., Gambino, A., Testolin, L., and Gerosa, G., "The last to die is hope: prolonged mechanical circulatory support with a Novacor left ventricular assist device as a bridge to transplantation", J Thorac Cardiovasc Surg, vol. 125, no. 2, pp. 417-418, 2003.   DOI   ScienceOn
3 Goldstein D.J., "Worldwide experience with the MicroMed DeBakey Ventricular Assist Device as a bridge to transplantation", Circulation, vol. 108 Suppl 1, no. pp. II272-277, 2003.
4 Timms D., Gregory, S., Hsu, P.L., Thomson, B., Pearcy, M., McNeil, K., Fraser, J., and Steinseifer, U., "Atrial versus ventricular cannulation for a rotary ventricular assist device", Artif Organs, vol. 34, no. 9, pp. 714-720, 2010.   DOI
5 Lim K.M., Lee, J.S., Song, J.H., Youn, C.H., Choi, J.S., and Shim, E.B., "Theoretical estimation of cannulation methods for left ventricular assist device support as a bridge to recovery", J Korean Med Sci, vol. 26, no. 12, pp. 1591-1598, 2011.   DOI   ScienceOn
6 Lim K.M., Kim, I.S., Choi, S.W., Min, B.G., Won, Y.S., Kim, H.Y., and Shim, E.B., "Computational analysis of the effect of the type of LVAD flow on coronary perfusion and ventricular afterload", J Physiol Sci, vol. 59, no. 4, pp. 307-316, 2009.   DOI
7 Park J.Y., Park C.Y., Hwang C.M., Sun, K., and Min B.G., "Pseudo-organ boundary conditions applied to a computational fluid dynamics model of the human aorta", Comput Biol Med, vol. 37, no. 8, pp. 1063-1072, 2007.   DOI
8 Biswajit Kar, Reynolds M. Delgado, O. H. Frazier, Igor D. Gregoric, Matthew T. Harting, Yasmin Wadia, Timothy J. Myers, Robert D. Moser, and Jonathan Freund, "The Effect of LVAD Aortic Outflow-Graft Placement on Hemodynamics and Flow Implantation Technique and Computer Flow Modeling", Tex Heart Inst J. vol. 32 no. 3, pp. 294-298, 2005.
9 George, Stephanie M. "Computational Analyses of an In-Vitro Aneurysm Model Based on Three-Dimensional Angiography With Comparison to Phase Contrast Magnetic Resonance Imaging and Dye Injection Studies." In:ASME 2010 Summer Bioengineering Conference. American Society of Mechanical Engineers, p. 163-164, 2010.
10 Nichols W.W. and O'Rourke M.F., "McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles.", 4th ed. 1998, London, UK: Edward Arnold.
11 Torii Ryo, Marie Oshima, Toshio Kobayashi, Kiyoshi Takagi, Tayfun E. Tezduyar. "Numerical investigation of the effect of hypertensive blood pressure on cerebral aneurysm dependence of the effect on the aneurysm shape". International Journal for Numerical Methods in Fluids, 54.68: 995-1009, 2007.   DOI