DOI QR코드

DOI QR Code

Rotatable sphincterotome as a rescue device for endoscopic retrograde cholangiopancreatography cannulation: a single-center experience

  • Takeshi Okamoto (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Takashi Sasaki (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Tsuyoshi Takeda (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Takafumi Mie (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Chinatsu Mori (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Takaaki Furukawa (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Yuto Yamada (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Akiyoshi Kasuga (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Masato Matsuyama (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Masato Ozaka (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research) ;
  • Naoki Sasahira (Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research)
  • Received : 2022.09.02
  • Accepted : 2023.01.02
  • Published : 2024.01.30

Abstract

Background/Aims: Selective bile duct or pancreatic duct cannulation remains a significant initial hurdle in endoscopic retrograde cholangiopancreatography (ERCP) despite advances in endoscopy and accessories. This study evaluated our experience with a rotatable sphincterotome in cases of difficult cannulation. Methods: We retrospectively reviewed ERCP cases using TRUEtome, a rotatable sphincterotome, as a rescue device for cannulation at a cancer institute in Japan from October 2014 to December 2021. Results: TRUEtome was used in 88 patients. Duodenoscopes were used for 51 patients, while single-balloon enteroscopes (SBE) were used for 37 patients. TRUEtome was used for biliary and pancreatic duct cannulation (84.1%), intrahepatic bile duct selection (12.5%), and strictures of the afferent limb (3.4%). Cannulation success rates were similar in the duodenoscope and SBE groups (86.3% vs. 75.7%, p=0.213). TRUEtome was more commonly used in cases with steep cannulation angles in the duodenoscope group and in cases requiring cannulation in different directions in the SBE group. There were no significant differences in adverse events between the two groups. Conclusions: The cannulation sphincterotome was useful for difficult cannulations in both unaltered and surgically altered anatomies. It may be an option to consider before high-risk procedures such as precut and endoscopic ultrasound-guided rendezvous techniques.

Keywords

References

  1. Bailey AA, Bourke MJ, Williams SJ, et al. A prospective randomized trial of cannulation technique in ERCP: effects on technical success and post-ERCP pancreatitis. Endoscopy 2008;40:296-301. https://doi.org/10.1055/s-2007-995566
  2. Varadarajulu S, Kilgore ML, Wilcox CM, et al. Relationship among hospital ERCP volume, length of stay, and technical outcomes. Gastrointest Endosc 2006;64:338-347. https://doi.org/10.1016/j.gie.2005.05.016
  3. Williams EJ, Taylor S, Fairclough P, et al. Are we meeting the standards set for endoscopy?: results of a large-scale prospective survey of endoscopic retrograde cholangio-pancreatograph practice. Gut 2007;56:821-829. https://doi.org/10.1136/gut.2006.097543
  4. Freeman ML, DiSario JA, Nelson DB, et al. Risk factors for post-ERCP pancreatitis: a prospective, multicenter study. Gastrointest Endosc 2001;54:425-434. https://doi.org/10.1067/mge.2001.117550
  5. Testoni PA, Mariani A, Giussani A, et al. Risk factors for post-ERCP pancreatitis in high- and low-volume centers and among expert and non-expert operators: a prospective multicenter study. Am J Gastroenterol 2010;105:1753-1761. https://doi.org/10.1038/ajg.2010.136
  6. Op den Winkel M, Schirra J, et al. Biliary cannulation in endoscopic retrograde cholangiography: how to tackle the difficult papilla. Dig Dis 2022;40:85-96. https://doi.org/10.1159/000515692
  7. Tse F, Yuan Y, Moayyedi P, et al. Double-guidewire technique in difficult biliary cannulation for the prevention of post-ERCP pancreatitis: a systematic review and meta-analysis. Endoscopy 2017;49:15-26.
  8. Facciorusso A, Ramai D, Gkolfakis P, et al. Comparative efficacy of different methods for difficult biliary cannulation in ERCP: systematic review and network meta-analysis. Gastrointest Endosc 2022;95:60-71. https://doi.org/10.1016/j.gie.2021.09.010
  9. Testoni PA, Mariani A, Aabakken L, et al. Papillary cannulation and sphincterotomy techniques at ERCP: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline. Endoscopy 2016;48:657-683. https://doi.org/10.1055/s-0042-108641
  10. Ryozawa S, Itoi T, Katanuma A, et al. Japan Gastroenterological Endoscopy Society guidelines for endoscopic sphincterotomy. Dig Endosc 2018;30:149-173. https://doi.org/10.1111/den.13001
  11. Harewood GC, Baron TH. An assessment of the learning curve for precut biliary sphincterotomy. Am J Gastroenterol 2002;97:1708-1712. https://doi.org/10.1111/j.1572-0241.2002.05829.x
  12. Akaraviputh T, Lohsiriwat V, Swangsri J, et al. The learning curve for safety and success of precut sphincterotomy for therapeutic ERCP: a single endoscopist's experience. Endoscopy 2008;40:513-516. https://doi.org/10.1055/s-2007-995652
  13. Rossos PG, Kortan P, Haber G. Selective common bile duct cannulation can be simplified by the use of a standard papillotome. Gastrointest Endosc 1993;39:67-69. https://doi.org/10.1016/S0016-5107(93)70015-2
  14. Cortas GA, Mehta SN, Abraham NS, et al. Selective cannulation of the common bile duct: a prospective randomized trial comparing standard catheters with sphincterotomes. Gastrointest Endosc 1999;50:775-779. https://doi.org/10.1016/S0016-5107(99)70157-4
  15. Schwacha H, Allgaier HP, Deibert P, et al. A sphincterotome-based technique for selective transpapillary common bile duct cannulation. Gastrointest Endosc 2000;52:387-391. https://doi.org/10.1067/mge.2000.107909
  16. Laasch HU, Tringali A, Wilbraham L, et al. Comparison of standard and steerable catheters for bile duct cannulation in ERCP. Endoscopy 2003;35:669-674. https://doi.org/10.1055/s-2003-41515
  17. Kurita A, Kudo Y, Yoshimura K, et al. Comparison between a rotatable sphincterotome and a conventional sphincterotome for selective bile duct cannulation. Endoscopy 2019;51:852-857. https://doi.org/10.1055/a-0835-5900
  18. Zhu F, Guan Y, Wang J. Efficacy and safety of the rotatable sphincterotome during ERCP in patients with prior Billroth II gastrectomy (with videos). Surg Endosc 2021;35:4849-4856. https://doi.org/10.1007/s00464-021-08417-x
  19. Maluf-Filho F, Kumar A, Ferreria de Souza T, et al. Rotatable sphincterotome facilitates bile duct cannulation in patients with altered ampullary anatomy. Gastroenterol Hepatol (N Y) 2008;4:59-62.
  20. Boston Scientific Corporation. TRUEtome product brochure [Internet]. Marlborough: Boston Scientific; 2022 [cited 2022 Feb 16]. Available from: https://www.bostonscientific.com/en-US/products/sphincterotomes/truetome-cannulating-sphincterotome.html.
  21. Cotton PB, Eisen GM, Aabakken L, et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010;71:446-454. https://doi.org/10.1016/j.gie.2009.10.027
  22. Okamoto T, Nakamura K, Yabuta M, et al. Retrograde endosonography-guided hepaticojejunostomy after failed rendezvous in a patient with Child's resection. Endoscopy 2022;54:E131-E132. https://doi.org/10.1055/a-1443-4244
  23. Yoshida A, Minaga K, Takeda O, et al. Successful biliary cannulation using a novel rotatable sphincterotome in a patient with situs inversus totalis. Endoscopy 2020;52:E333-E334. https://doi.org/10.1055/a-1122-8416
  24. Matsubara S, Oka M, Nagoshi S. Rotatable sphincterotome as a salvage for guidewire manipulation in endoscopic ultrasound-guided hepaticogastrostomy. Dig Endosc 2021;33:e119-e120. https://doi.org/10.1111/den.14012
  25. Takenaka M, Minaga K, Kamata K, et al. Efficacy of a modified double-guidewire technique using an uneven double lumen cannula (uneven method) in patients with surgically altered gastrointestinal anatomy (with video). Surg Endosc 2020;34:1432-1441. https://doi.org/10.1007/s00464-019-07228-5
  26. Moxon DR, Hong K, Brown RD, et al. Selective intrahepatic ductal cannulation during ERCP with a sphincterotome. Gastrointest Endosc 2003;57:738-743. https://doi.org/10.1067/mge.2003.173