Browse > Article
http://dx.doi.org/10.5090/kjtcs.2011.44.5.338

Direct Axillary Arterial Cannulation Using Seldinger's Technique in Aortic Dissection  

Do, Young-Woo (Department of Thoracic and Cardiovascular Surgery, Kyungpook University Hospital)
Kim, Gun-Jik (Department of Thoracic and Cardiovascular Surgery, Kyungpook University Hospital)
Park, Il (Department of Thoracic and Cardiovascular Surgery, Kyungpook University Hospital)
Cho, Joon-Yong (Department of Thoracic and Cardiovascular Surgery, Kyungpook University Hospital)
Lee, Jong-Tae (Department of Thoracic and Cardiovascular Surgery, Kyungpook University Hospital)
Publication Information
Journal of Chest Surgery / v.44, no.5, 2011 , pp. 338-342 More about this Journal
Abstract
Background: The axillary artery is frequently used for cardiopulmonary bypass, especially in acute aortic dissection. We have cannulated the axillary artery using a side graft or by directly using Seldinger's technique. The purpose of this study was to assess the technical problems and complications of both cannulation techniques. Materials and Methods: From January 2003 to December 2009, 53 patients underwent operations using the axillary artery for arterial cannulation. The axillary artery was cannulated with a side graft in 35 patients (side graft group) and directly using Seldinger's technique in 18 patients (direct group). Results: The results were compared between two groups, focusing on cannulation-related morbidities including neurologic morbidity. Arterial damage or dissection of the axillary artery occurred in 1 (2.9%) patient in the side graft group and in 1 (5.6%) patient in the direct group. Malperfusion and insufficient flow did not occur in either group. There were no postoperative complications related to axillary cannulation, such as brachial plexus injury, compartment syndrome, or local wound infection, in either group. Conclusion: Technical problems and complications of the axillary arterial cannulation in both techniques were rare. Direct arterial cannulation using Seldinger's technique was done safely and more simply than the previous technique. It was concluded that both axillary arterial cannulation techniques are acceptable and it remains the surgeon's preference which technique should be used.
Keywords
Aortic dissection; Axillary artery; Cannulation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Mazzola A, Gregorini R, Villani C, Di Eusanio M. Antergrade cerebral perfusion by axillary artery and Left carotid artery inflow at moderate hypothermia. Eur J Cardiothorc Surg 2002;21:930-1.   DOI   ScienceOn
2 Mitumasa H, Mitsunori S, Akira S, et al. Outcome of less invasive proximal arch replacement with moderate hypothermic circulatory arrest followed by aggressive rapid re-warming in emergency surgery for type A acute aortic dissection. Circ J 2009;73:69-72.   DOI   ScienceOn
3 Sinclair MC, Singer RL, Manley NJ, Montesano RM. Cannulation of the axillary artery for cardiopulmonary bypss: safeguards and pitfalls. Ann Thorac Surg 2003;75:931-4.   DOI   ScienceOn
4 Sabik JF, Nemeh H, Lytle BW, et al. Cannulation of the axillary artery with a side graft reduces morbidity. Ann Thorac Surg 2004;77:1315-20.   DOI   ScienceOn
5 Yilik L, Emrecan B, Kestelli M, et al. Direct versus side-graft cannulation of the right axillary artery for antegrade cerebral perfusion. Tex Heart Inst J 2006;33:310-5.
6 Ergin MA, Uysal S, Reich DL, et al. Temporary neurological dysfunction after deep hypothermic circulatory arrest: A clinical marker of long-term functional deficit. Ann Thorac Surg 1999;67:1887-90.   DOI   ScienceOn
7 Whitlark JD, Goldman SM, Sutter FP. Axillary artery cannulation in acute ascending aortic dissection. Ann Thorac Surg 2000;69:1127-9.   DOI   ScienceOn
8 Schachner T, Nagiller J, Zimmer A, Laufer G, Bonatti J. Technical problems and complications of axillary artery cannulation. Eur J Cardiothorc Surg 2005;27:634-7.   DOI   ScienceOn
9 Yuiichi T, Koichi A, Satoshi K, et al. Coexistent true aortic aneurysm as a cause of acute aortic dissection. Circ J 2009; 73:822-5.   DOI   ScienceOn
10 Bortst HG. Axillary artery for extracorporeal circulation. J Thorac Cardiovasc Surg 1995;110:1775.
11 Bortst HG. Surgical tactics and techniques. In: Borst HG, Heinermann MK, Stone CD. Surgical treatment of aortic dissection. New York: Churchill Livingstone. 1996;255-68.
12 Sabik JF, Lytle BW, McCarthy PM, Cosgrove DM. Axillary artery: an alternative site of arterial cannulation for patients with extensive aortic and peripheral vascular disease. J Thorac Cardiovasc Surg 1995;109:885-91.   DOI   ScienceOn
13 Neri E, Massetti M, Capannini G, et al. Axillary artery cannulation in type A aortic dissection operation. J Thorac Cardiovasc Surg 1999;118:324-9.   DOI   ScienceOn
14 Yavuz S, Goncu MT, Turk T. Axillary artery cannulation for arterial inflow in patients with acute dissection of the ascending aorta. Eur J Cardiothorc Surg 2002;22:313-5.   DOI   ScienceOn