• Title/Summary/Keyword: Cancer treatments

Search Result 783, Processing Time 0.033 seconds

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

Effect of a Needle Aspiration in Patients with Lymphedema (암 수술 후 발생한 림프부종 환자의 바늘 흡인술 효과)

  • Yang, Gu-Hwan;Kwak, Sung-Wook;Kim, Sun-Hyn;Shin, Young-Tae;Hwang, Hee-Jin;Park, No-Hyeok;Yeom, Chang-Hwan
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2009
  • Purpose: Lymphedemas are tissue fluid swellings, usually on the arms or legs, and occur as a result of impaired lymphatic drainage. Presently, the most effective treatment available is complete decongestive physiotherapy (CDP). However, this therapy is ineffective in some patients and surgery may be indicated. Herein, we examined the efficacy of minimally invasive needle aspiration of the most enlarged areas in hypodermic adipose tissues, of patients who had failed CDP. Methods: We included 21 patients who were diagnosed with lymphedema stage II-III in the upper or lower extremities and visited the lymphedema clinic at a university hospital from September 1, 2003 to February 28, 2004. All patients had been treated with CDP at least once, but had failed to respond to the therapy for more than one year. Nine patients had breast cancer and 12 had cervical cancer. We identified the area with the most severe edema by using MRI and performed a 16-gauge angio-needle aspiration on the area. The patients were followed up for 3 months. Effectiveness of the treatment was evaluated by comparing the volume of edema before and after the treatment using Wilcoxon signed rank-test. Results: The mean reduction ratio of the volume of edema comparison normal volume was 41.1${\pm}$35.3% (P=0.001). There were no major or minor operative complications except localized hemorrhage. Conclusion: We conclude that a needle aspiration prior to other surgical treatments is relatively safe and effective for those patients who are unresponsive to CDP.

  • PDF

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

Polyamines Modulate Growth factor-Induced Membrane Protein Phosphorylation in MCF-7 Human Breast Cancer Cells (MCF-7 유방암세포에 있어서 growth factor에 의해 유도된 막 단백질의 인산화에 대한 폴리아민의 조절)

  • Lee, Ji-Young;Kim, Ji-Hyun;Lee, Kyeong-Hee;Kim, Byeong-Gee
    • Journal of Life Science
    • /
    • v.12 no.2
    • /
    • pp.164-172
    • /
    • 2002
  • Breast cancer cell lines display a wide variety of growth factor receptors, and considerable evidences implicate the importance of signalings from those receptors. A useful prognostic indicator would be the level of activity of a second messenger protein used in common by these receptors. Our studies were designed to obtain preliminary information on the possible role of polyamine as a mediator of the membrane-associated protein phosphorylation and as a regulator of second messenger in mitogenic signal of estrogen or growth factors in MCF-7 human breast lancer cells. DFMO significantly inhibited the phosphorylation induced by $E_2$, TGF-$\alpha$ and EGF in membrane-associated proteins (154, 134, 116, and 104 kDa). Exogenous polyamines abolished the inhibitory effect of DFMO. Tyrosine phosphorylations of membrane-associated proteins were not increased by $E_2$ or growth factor treatments and not affected DFMO treatment. Polyamine administration markedly enhanced the tyrosine phosphorylation of membrane-associated proteins (154, 134, and 116 kDa). In the present study, $E_2$ and TGF-$\alpha$ and EGF enhanced protein phosphorylation in the almost same levels. These data indicate that $E_2$ and growth factor signaling pathway may cross-talk through various protein kinase which phosphorylated many substrate proteins (154, 134, 116 and 104 kDa). Polyamines may be involved in growth signaling pathway of $E_2$ and TGF-$\alpha$ or EGF for the cross-talk through regulation of the protein phosphorylation such as 154, 134, 116 and 104 kDa. Polyamine may also selectively interfere with several different protein kinases, and the specific steps in signal transduction system were effected by polyamines.

Current Situation on Signing Advance Medical Directives and Actual Life-sustaining Treatment Given at a University Hospital (일개 대학병원의 연명치료 선택 및 사전의료의향서 작성 현황)

  • Yoon, Ho-Min;Choi, Youn-Seon;Hyun, Jong-Jin
    • Journal of Hospice and Palliative Care
    • /
    • v.14 no.2
    • /
    • pp.91-100
    • /
    • 2011
  • Purpose: This study was performed to investigate patients' preferences on receiving life-sustaining treatments (LST) and to analyze the relationship between patients' characteristics and LST selection. We also examined any discrepancy between LST patients' choices regarding medical intervention and actual medical intervention given/not given within 48 hours before death. Methods: This cross-sectional study was performed from March 1, 2008 to August 31, 2008 in the Palliative Care Unit of Korea University Hospital. Electric medical records (EMR) of 102 hospice cancer patients were reviewed, and 74 patients with Glasgow coma scale (GCS) ${\geq}$10 at the time of signing the advance medical directives (AMD) were selected for the first analysis. Then, patients alive at the end of this study, transferred to other hospitals or dead within 48 hours were excluded, and the remaining 42 patients were selected for the second analysis. Results: Preferred LST included antibiotics, total parenteral nutrition, tube feeding, transfusion, and laboratory and imaging studies. The relationship between patients' characteristics and LST could not be analyzed due to skewed preferences. LST chosen at the time of signing the AMD and actual medical intervention given/not given in the last 48 hours showed discrepancy in most cases. Conclusion: When making AMD in hospice cancer patients, it is important to consider the time and possibility of changing the choices. Above all, patients must fully understand the AMD. Thus, LST should always be provided with careful consideration of all possibilities, because legal and social aspects of AMD have not been established yet.

Treatments Results and Prognostic Factors in Locally Advanced Hypopharyngeal Cancer (국소 진행된 하인두암의 치료 결과와 예후 인자 분석)

  • Yoon, Mee-Sun;Ahn, Sung-Ja;Nam, Taek-Keun;Song, Ju-Young;Nah, Byung-Sik;Lim, Sang-Cheol;Lee, Joon-Kyoo;Chung, Woong-Ki
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.151-159
    • /
    • 2007
  • Purpose: The purpose of this study is to present the treatment results and to identify possible prognostic indicators in patients with locally advanced hypopharyngeal carcinoma. Materials and Methods: Between October 1985 to December 2000, 90 patients who had locally advanced stage IV hypopharyngeal carcinoma were studied retrospectively. Twelve patients were treated with radiotherapy alone, 65 patients were treated with a combination of chemotherapy and radiotherapy, and 13 patients were treated with surgery and postoperative radiotherapy with or without neoadjuvant chemotherapy. Total radiation dose ranged from 59.0 to 88.2 Gy (median 70 Gy) for radiotherpay alone. Most patients had ciplatin and 5-fluorouracil, and others had cisplatin and pepleomycin or vincristin. Median follow-up period was 15 months. Kaplan-Meier method was used for survival rate and Cox proportional hazard model for multivariate analysis of prognostic factors. Results: Overall 3-and 5-year survival rates were 27% and 17%, respectively. The 2-year locoregional control rates were 33% for radiotherapy alone, 32% for combined chemotherapy and radiotherapy, and 81 % for combined surgery and radiotherapy (p=0.006). The prognostic factors affecting overall survival were T stage, concurrent chemoradiation and treatment response. Overall 3-and 5-year laryngeal preservation rates in combined chemotherapy and radiotherapy were 26% and 22%, respectively. Of these, the 5-year laryngeal preservation rates were 52% for concurrent chemoradiation group (n=11), and 16% for neoadjuvant chemotherapy and radiotherapy (n=54, p=0.012). Conclusion: Surgery and postoperative radiotherapy showed better results than radiotherapy alone or with chemotherapy. Radiotherapy combined with concurrent chemotherapy is an effective modality to achieve organ preservation in locally advanced hypopharyngeal cancer. Further prospective randomized studies will be required.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.