• Title/Summary/Keyword: Cancer registration

Search Result 168, Processing Time 0.024 seconds

Evaluating Correlation between Geometrical Relationship and Dose Difference Caused by Respiratory Motion Using Statistical Analysis

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Cho, Min-Seok;Noh, Yu-Yoon;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.203-212
    • /
    • 2016
  • Dose differences between three-dimensional (3D) and four-dimensional (4D) doses could be varied according to the geometrical relationship between a planning target volume (PTV) and an organ at risk (OAR). The purpose of this study is to evaluate the correlation between the overlap volume histogram (OVH), which quantitatively shows the geometrical relationship between the PTV and OAR, and the dose differences. 4D computed tomography (4DCT) images were acquired for 10 liver cancer patients. Internal target volume-based treatment planning was performed. A 3D dose was calculated on a reference phase (end-exhalation). A 4D dose was accumulated using deformation vector fields between the reference and other phase images of 4DCT from deformable image registration, and dose differences between the 3D and 4D doses were calculated. An OVH between the PTV and selected OAR (duodenum) was calculated and quantified on the basis of specific overlap volumes that corresponded to 10%, 20%, 30%, 40%, and 50% of the OAR volume overlapped with the expanded PTV. Statistical analysis was performed to verify the correlation with the OVH and dose difference for the OAR. The minimum mean dose difference was 0.50 Gy from case 3, and the maximum mean dose difference was 4.96 Gy from case 2. The calculated range of the correlation coefficients between the OVH and dose difference was from -0.720 to -0.712, and the R-square range for regression analysis was from 0.506 to 0.518 (p-value <0.05). However, when the 10% overlap volume was applied in the six cases that had OVH value ${\leq}2$, the average percent mean dose differences were $34.80{\pm}12.42%$. Cases with quantified OVH values of 2 or more had mean dose differences of $29.16{\pm}11.36%$. In conclusion, no significant statistical correlation was found between the OVH and dose differences. However, it was confirmed that a higher difference between the 3D and 4D doses could occur in cases that have smaller OVH value.

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

Multicenter Analysis of Gestational Trophoblastic Neoplasia in Turkey

  • Ozalp, Sabit Sinan;Telli, Elcin;Oge, Tufan;Tulunay, Gokhan;Boran, Nurettin;Turan, Taner;Yenen, Mufit;Kurdoglu, Zehra;Ozler, Ali;Yuce, Kunter;Ulker, Volkan;Arvas, Macit;Demirkiran, Fuat;Bese, Tugan;Tokgozoglu, Nedim;Onan, Anil;Sanci, Muzaffer;Gokcu, Mehmet;Tosun, Gokhan;Dikmen, Yilmaz;Ozsaran, Aydin;Terek, Mustafa Cosan;Akman, Levent;Yetimalar, Hakan;Kilic, Derya Sakarya;Gungor, Tayfun;Ozgu, Emre;Yildiz, Yunus;Kokcu, Arif;Kefeli, Mehmet;Kuruoglu, Serkan;Yuksel, Hasan;Guvenal, Tevfik;Hasdemir, Pinar Solmaz;Ozcelik, Bulent;Serin, Serdar;Dolanbay, Mehmet;Arioz, Dagistan Tolga;Tuncer, Nadire;Bozkaya, Hasan;Guven, Suleyman;Kulaksiz, Deniz;Varol, Fusun;Ali, Yanik;Ogurlu, Gonca;Simsek, Tayyup;Toptas, Tayfun;Dogan, Selen;Camuzoglu, Hakan;Api, Murat;Guzin, Kadir;Eray, Caliskan;Doger, Emek
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3625-3628
    • /
    • 2014
  • Background: To evaluate the incidence, diagnosis and management of GTN among 28 centers in Turkey. Materials and Methods: A retrospective study was designed to include GTN patients attending 28 centers in the 10-year period between January 2003 and May 2013. Demographical characteristics of the patients, histopathological diagnosis, the International Federation of Gynecology and Obstetrics (FIGO) anatomical and prognostic scores, use of single-agent and multi-agent chemotherapy, surgical interventions and prognosis were evaluated. Results: From 2003-2013, there were 1,173,235 deliveries and 456 GTN cases at the 28 centers. The incidence was calculated to be 0.38 per 1,000 deliveries. According to the evaluated data of 364 patients, the median age at diagnosis was 31 years (range, 15-59 years). A histopathological diagnosis was present for 45.1% of the patients, and invasive mole, choriocarcinoma and PSTTs were diagnosed in 22.3% (n=81), 18.1% (n=66) and 4.7% (n=17) of the patients, respectively. Regarding final prognosis, 352 (96.7%) of the patients had remission, and 7 (1.9%) had persistence, whereas the disease was mortal for 5 (1.4%) of the patients. Conclusions: Because of the differences between countries, it is important to provide national registration systems and special clinics for the accurate diagnosis and treatment of GTN.

Clinical Application of Dose Reconstruction Based on Full-Scope Monte Carlo Calculations: Composite Dose Reconstruction on a Deformed Phantom (몬테칼로 계산을 통한 흡수선량 재구성의 임상적 응용: 변형된 팬텀에서의 총제적 선량재구성)

  • Yeo, Inhwan;Xu, Qianyi;Chen, Yan;Jung, Jae Won;Kim, Jong Oh
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.139-142
    • /
    • 2014
  • The purpose of this study was to develop a system of clinical application of reconstructed dose that includes dose reconstruction, reconstructed dose registration between fractions of treatment, and dose-volume-histogram generation and to demonstrate the system on a deformable prostate phantom. To achieve this purpose, a deformable prostate phantom was embedded into a 20 cm-deep and 40 cm-wide water phantom. The phantom was CT scanned and the anatomical models of prostate, seminal vesicles, and rectum were contoured. A coplanar 4-field intensity modulated radiation therapy (IMRT) plan was used for this study. Organ deformation was simulated by inserting a "transrectal" balloon containing 20 ml of water. A new CT scan was obtained and the deformed structures were contoured. Dose responses in phantoms and electronic portal imaging device (EPID) were calculated by using the XVMC Monte Carlo code. The IMRT plan was delivered to the two phantoms and integrated EPID images were respectively acquired. Dose reconstruction was performed on these images using the calculated responses. The deformed phantom was registered to the original phantom using an in-house developed software based on the Demons algorithm. The transfer matrix for each voxel was obtained and used to correlate the two sets of the reconstructed dose to generate a cumulative reconstructed dose on the original phantom. Forwardly calculated planning dose in the original phantom was compared to the cumulative reconstructed dose from EPID in the original phantom. The prescribed 200 cGy isodose lines showed little difference with respect to the "prostate" and "seminal vesicles", but appreciable difference (3%) was observed at the dose level greater than 210 cGy. In the rectum, the reconstructed dose showed lower volume coverage by a few percent than the plan dose in the dose range of 150 to 200 cGy. Through this study, the system of clinical application of reconstructed dose was successfully developed and demonstrated. The organ deformation simulated in this study resulted in small but observable dose changes in the target and critical structure.

A study on Hospital based Home Health Care Service and the Level of Client Satisfaction (일 대학 병원의 가정간호시범사업 서비스 내용 및 만족도에 대한 조사연구)

  • Kim Chung Nam;Kwan Young Sook;Koh Hyo Jung;Kim Myung Ae;Park Chung Ja;Shin Yeong Hee;Lee Byung Sook;Lee Kyung Hee;Seo Hanng Suk
    • Journal of Korean Public Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.246-259
    • /
    • 2000
  • The purpose of this study was to assess the provided home health care services and to evaluate the patient's satisfaction level of received home health care services. Well trained two home health care nurses interviewed with 138 respondents who received home health care by Keimyung University Hospital from January 1st to August 31st 1999. The results were summarized as follows : 1) Among 138 respondents, $55.8\%$ were mail and $44.2\%$ were female and $70.3\%$ of them were over sixty years old. Respondents main family care givers were spouse$(53.6\%)$, daughters and sons$(36.2\%)$ and parents$(7.2\%)$. 2) $60.2\%$ of cancer patients received home health care services, $23.3\%$ of cerebral­cardiovascular patients, $7.5\%$ of endocrine disorder patients, $2.3\%$ of those who have indwelling foley catheter patients, $1.5\%$ of those who have respiratory problems and others$(5.2\%)$. 3) $88.1\%$ of respondents were satisfied with the number of home visits they received. $50.5\%$ of respondents' were received 1 to 3 times of home visits by home health care nurse per month. $48.6\%$ of respondents answered they were introduced by attending doctors or nurses to home health care services. $55.8\%$ of respondents answered registration to home health care services was simple and easy. $97.4\%$ of respondents answered home health care payment system was adequate. $64.9\%$ of respondents answered the cost of home health care per visit was adequate and comfortable. 4) Health education, counselling, physical assessment was provided to most of the patients. Those who suffered with cerebral-cardiovascular disease was needed hands on direct care most of all. The least home health care service provided was medication. 5) The satisfaction measurement tool was composed with 13 items and 3 score scale. The mean score of satisfaction on provided home health care services was 2.67 out of 3. Among 13 items. 'home health care service was kind enough' was highest(2.84). 'nurse use precise word to understand and communicate'. 'nurse gave home visiting notice ahead of time and kept the home visiting promise on time' was 2.83. 'whenever I need home health care nurse I can give a call and meet the nurse' was lowest 2.41. Special Home Health care programs such as comprehensive hospice care programs for elders over sixty years old should be organized. Adequate and standardized home health care payment system should be developed as soon as possible. In korean family situation. when family members are getting sick and stay at home. family members were taking care of the patients. special program such as counselling family members are needed.

  • PDF

Evaluation on Management of Unified Health Subcenters (통합보건지소 운영 평가)

  • Kang, Pock-Soo;Lee, Kyeong-Soo;Hwang, Tae-Yoon;Kim, Chang-Yoon
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • Objectives: This study is designed to suggest the health service goals necessary for providing the more efficient services relevant to the requests of the community, through the evaluation on the operating status of the unified health subcenters. Methods: We visited total 5 unified health subcenters comprising 3 ones located in Gyeongsangbuk-do and 2 ones located in Gyeongsangnam-do from December 2000 to January 2001, and interviewed about the pre- and post-unified status related to manpower, facilities, equipment, medical service and health service quality, and the problems and improvement plans of the unified management. Results: According to the evaluation on the manpower before and after the unification of the health subcenters, the total employees increased by 2.8 persons on average from 6.8 to 9.6 persons in the investigated subjects. The numbers of doctors, dentists and nurses were almost the same as before. There were no clinical pathologic technician and radiological technician before but they were appointed to duty in 3 unified health subcenters later. The unification of the health subcenters has produced slight increases in the frequency of the medical service and dental treatment and considerable increases in that of the physical therapy and laboratory tests. In relating to the changes of the health service, the cases of visiting health care and ambulatory medical service, and the total number of health education participants were greatly increased after the unification. The number of cases undergoing the vaccination and cervical cancer screening was similar to that of the pre-unification while the patient number of the registration to hypertension or diabetes showed a tendency to increase a little. Since the unification of the health subcenters, the frequency of laboratory tests has been increased, but the quality of health service has not been improved yet. Nevertheless, the unification seems to be positive according to the result of the great improvement in visiting health care, ambulatory medical service and health education service. The problems of the unification of the health subcenters were indicated in indefiniteness of the service details between the workers; excessively large building hard to be effectively managed; insufficient medical instruments, inappropriation of working expenses, lack of professional training for the health education, etc. Conclusions: For further active functions of the unified health subcenters, the minimal allocation basis to appoint doctors, nurses and administrative workers to do the duty should be differentiated from the basis for a health subcenter, and the fundamental instruments needs to be expanded to improve the quality of the medical service and visiting health care service. Moreover, the unified health subcenter needs to have definite service details between the workers, and should improve the working efficiency through the development of service-related guidelines.

  • PDF

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF