• 제목/요약/키워드: Cancer imaging

검색결과 1,199건 처리시간 0.027초

Characterizations of Two-step Matrix Application Procedures for Imaging Mass Spectrometry

  • Shimma, Shuichi
    • Mass Spectrometry Letters
    • /
    • 제6권1호
    • /
    • pp.21-25
    • /
    • 2015
  • In this paper, I describe the importance of matrix spraying conditions in imaging mass spectrometry (IMS) to obtain successful imaging results. My developed matrix application methodology, which is a "two-step matrix application" sequentially combined with matrix sublimation and spraying matrix solution can provide high reproducibility and high ion yield compared with a conventional direct spraying method. However, insufficient IMS results were obtained occasionally despite the two-step method. Therefore, I wanted to characterize the methodology to continuously provide high quality data. According to my results, the sublimation time was not a strict parameter, and the most important step was the first spraying condition. This means that the extraction conditions from the tissue section and co-crystallization of the matrix were the most important factors.

MR Imaging of Radiation-Induced Lumbosacral Plexopathy, as a Rare Complication of Concomitant Chemo-Radiation for Cervical Cancer

  • Hwang, Eun Taeg;Son, Hye Min;Kim, Jin Young;Moon, Sung Min;Lee, Ho Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권1호
    • /
    • pp.46-50
    • /
    • 2020
  • Radiation-induced lumbosacral plexopathy (RILSP) is an uncommon complication of pelvic radiotherapy that can result in different degrees of sensory and motor deficits. An age 59 female with cervical cancer, who had received combined chemotherapy and radiation therapy two years before, presented with bilaterally symmetric lower-extremity weakness and tingling sensation. The magnetic resonance imaging showed diffuse T2 bright signal intensity and mild enhancement along the bilateral lumbosacral plexus with no space-occupying masses. RILSP was diagnosed after the exclusion of malignant and inflammatory plexopathies.

Radiomics in Breast Imaging from Techniques to Clinical Applications: A Review

  • Seung-Hak Lee;Hyunjin Park;Eun Sook Ko
    • Korean Journal of Radiology
    • /
    • 제21권7호
    • /
    • pp.779-792
    • /
    • 2020
  • Recent advances in computer technology have generated a new area of research known as radiomics. Radiomics is defined as the high throughput extraction and analysis of quantitative features from imaging data. Radiomic features provide information on the gray-scale patterns, inter-pixel relationships, as well as shape and spectral properties of radiological images. Moreover, these features can be used to develop computational models that may serve as a tool for personalized diagnosis and treatment guidance. Although radiomics is becoming popular and widely used in oncology, many problems such as overfitting and reproducibility issues remain unresolved. In this review, we will outline the steps of radiomics used for oncology, specifically addressing applications for breast cancer patients and focusing on technical issues.

Detection of Recurrence in a Surveillance Program for Epithelial Ovarian Cancer

  • Suprasert, Prapaporn;Chalapati, Wadwilai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7193-7196
    • /
    • 2013
  • Ovarian cancer patients need a surveillance program for the detection of tumor progression after completion of treatment. The methods generally consist of history taking, physical examination, tumor marker monitoring and imaging. However, the details of recurrence detection with each method are not well defined. To clarify this issue, ovarian cancer patients who achieved complete or partial responses and developed tumor progression at the follow up time between January 2004 and December 2010 in University Hospital Chiang Mai, Thailand, were reviewed. Clinical data, CA 125 level and imaging results at the tumor progression time were recorded and analyzed. There were 144 ovarian cancer patients meeting the inclusion criteria with the mean age of 51 years and 62.5% of them were in an advanced stage. Complete response was achieved in 89 patients (61.8%) after primary treatment. The median progression free survival and overall survival were 15.5 months and 37.5 months, respectively. Abnormal symptoms presented in 49.3% of the studied patients and 59.7% developed physical examination abnormalities. In addition, CA 125 was elevated in 89.6% while in 74.3% of tumor progression was identified by CT-scan. Short treatment time period and a high level of CA 125 were significant independent prognostic factors in these patients. In conclusion, careful history taking, physical examination and monitoring of CA 125 levels are important methods for tumor progression detection in a surveillance program for epithelial ovarian cancer patients.

The development of a fully automated homemade system for [11C] acetate synthesis using an open source PLC

  • Kang, Se Hun;Hong, Sung Tack;Park, Kwangseo;Kim, Seok-ki
    • 대한방사성의약품학회지
    • /
    • 제2권2호
    • /
    • pp.103-107
    • /
    • 2016
  • Solid phase extraction (SPE) purification method is the efficient and well-known tool for automated [$^{11}C$]acetate synthesis. A fully automated homemade module adopting the SPE method and 'pinch' valves was developed very economically with a universal interface board, a relay card and an open source programmable logic controller. The radiochemical yield of the optimized [$^{11}C$]acetate synthesis by this system was $58.8{\pm}2.1%$ (n=10, decay-corrected) from $15.5{\pm}0.19GBq$ of $[^{11}C]CO_2$ as starting activity, and total synthetic time was 15 minutes. HPLC analysis showed its high radiochemical purity as $97.4{\pm}1.1%$ without possible by-products.

인두암과 식도암의 새로운 진단내시경 (New Diagnostic Techniques in Cancer of the Pharynx and Esophagus)

  • 조주영;조원영
    • 대한기관식도과학회지
    • /
    • 제17권1호
    • /
    • pp.14-18
    • /
    • 2011
  • The diagnosis and treatment of early gastrointestinal cancers is the gastroenterologists' mission because of national cancer screening program in South Korea. The detection of early cancers is emphasized, because these were previously treated with surgical treatment can be currently cured with endoscopic treatment. Gastroenterologists who achieved at least on some level can make an exact diagnosis regardless of what type of endoscopy, but generally, there are some required conditions for an optimal diagnosis. First, clinically important lesions have to be detected easily. Second, the border and morphology of lesions have to be characterized easily. Third, lesions have to be diagnosed exactly. Precancers and early cancers are often subtle and can pose a challenge to gastroenterologists to visualize using standard white light endoscopy. The use of dye solutions aids the diagnosis of early gastrointestinal cancers, however, it is a quite cumbersome to use dye solutions all the time and the solution often bothers the exact observation by pooling into the depression or ulceration of the lesion. To overcome this weakness, newer endoscopes are now developed so called "image enhanced endoscopy" using optical and/or electronic methods such as narrow band imaging (NBI), autofluorescence imaging (AFI), i-scan, flexible spectral imaging color enhancement (FICE) and confocal endomicroscopy (CLE).

  • PDF

FAP Inhibitors as Novel Small Molecules for Cancer Imaging using Radionuclide

  • Anvar Mirzaei;Jung-Joon Min;Dong-Yeon Kim
    • 대한방사성의약품학회지
    • /
    • 제9권1호
    • /
    • pp.49-55
    • /
    • 2023
  • Tumors are encircled by various non-cancerous cell types in the extracellular matrix, including fibroblasts, endothelial cells, immune cells, and cytokines. Fibroblasts are the most critical cells in the tumor stroma and play an important role in tumor development, which has been highlighted in some epithelial cancers. Many studies have shown a tight connection between cancerous cells and fibroblasts in the last decade. Regulatory factors secreted into the tumor environment by special fibroblast cells, cancer-associated fibroblasts (CAFs), play an important role in tumor and vessel development, metastasis, and therapy resistance. This review addresses the development of FAP inhibitors, emphasizing the first, second, and latest generations. First-generation inhibitors exhibit low selectivity and chemical stability, encouraging researchers to develop new scaffolds based on preclinical and clinical data. Second-generation enzymes such as UAMC-1110 demonstrated enhanced FAP binding and better selectivity. Targeted treatment and diagnostic imaging have become possible by further developing radionuclide-labeled fibroblast activation protein inhibitors (FAPIs). Although all three FAPIs (01, 02, and 04) showed excellent preclinical and clinical findings. The final optimization of these FAPI scaffolds resulted in FAPI-46 with the highest tumor-to-background ratio and better binding affinity.

Pancreatic Arteriovenous Malformation as an Unusual Cause of Chronic Gastrointestinal Bleeding in a Patient with Early Gastric Cancer: Multimodality Imaging Spectrum with Pathologic Correlation

  • Lee, Borahm;Lee, Jeong Eun;Cho, June Sik;Shin, Kyung Sook;You, Sun Kyoung;Cheon, Kwang Sik;Song, In Sang;Kim, Kyung Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권4호
    • /
    • pp.241-247
    • /
    • 2015
  • Arteriovenous malformation (AVM) of the pancreas is extremely rare, although it may be increasingly diagnosed due to the widespread use of cross-sectional imaging of the abdomen. Early diagnosis of this disease is important to prevent delay of treatment and resulting fatal complications. We report a rare case of pancreatic AVM in a 48-year-old man who presented with severe chronic anemia and early gastric cancer, which made diagnosis challenging. Imaging findings, including ultrasound, computed tomography, and magnetic resonance imaging, are shown, as well as the pathologic features.

Upgrade of gamma electron vertex imaging system for high-performance range verification in pencil beam scanning proton therapy

  • Kim, Sung Hun;Jeong, Jong Hwi;Ku, Youngmo;Jung, Jaerin;Cho, Sungkoo;Jo, Kwanghyun;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1016-1023
    • /
    • 2022
  • In proton therapy, a highly conformal proton dose can be delivered to the tumor by means of the steep distal dose penumbra at the end of the beam range. The proton beam range, however, is highly sensitive to range uncertainty, which makes accurately locating the proton range in the patient difficult. In-vivo range verification is a method to manage range uncertainty, one of the promising techniques being prompt gamma imaging (PGI). In earlier studies, we proposed gamma electron vertex imaging (GEVI), and constructed a proof-of-principle system. The system successfully demonstrated the GEVI imaging principle for therapeutic proton pencil beams without scanning, but showed some limitations under clinical conditions, particularly for pencil beam scanning proton therapy. In the present study, we upgraded the GEVI system in several aspects and tested the performance improvements such as for range-shift verification in the context of line scanning proton treatment. Specifically, the system showed better performance in obtaining accurate prompt gamma (PG) distributions in the clinical environment. Furthermore, high shift-detection sensitivity and accuracy were shown under various range-shift conditions using line scanning proton beams.

Comparison Analysis of Donor Liver Volumes Estimated with 3D Magnetic Resonance and 3D Computed Tomography Image Data

  • Kim, Myeong-Seong;Park, Kyeong-Seok;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.261-265
    • /
    • 2014
  • Three-dimensional computed tomography is an effective tool to estimate the liver volume of living donors for the live liver transplantation. When additional operation is required, magnetic resonance imaging is conducted to determine the safety of the donor. This study compared the accuracy of magnetic resonance imaging and computed tomography in estimating 3D liver volume of 23 male and 7 female donors who underwent both magnetic resonance imaging and computed tomography tests before the transplantation. The analysis was conducted to see whether the liver's estimated total volumes and the left lobe volumes obtained from 3D-magnetic resonance imaging and 3D-computed tomography were identical. Volumes of the right lobe estimated with 3D-magnetic resonance imaging and 3D-computed tomography were compared with the actual volume of the right lobe harvested in the operating room because the volume of the right lobe is an important determinant in the safety of the donor. The total volume of the liver estimated from 3D-magnetic resonance imaging and 3D-computed tomography differed (1238.1904 units and 1402.364 units respectively). The left lobe volume of the liver estimated with 3D-magnetic resonance imaging and 3D-computed tomography also differed (450.530 units and 554.490 units, respectively). The right lobe volume of the liver estimated with 3D-magnetic resonance imaging and 3D-computed tomography were 787.660 units and 847.545 units, respectively, while the actual average right lobe volume of the harvested liver was 678.636 units. 3D-computed tomography has been widely used to estimate the right lobe volume of the donors' liver. However, 3D-magnetic resonance imaging was also very effective in estimating the volume of the liver. Thus, 3D-magnetic resonance imaging is also expected to become an important tool in determining the safety of the donors before transplantation.