• Title/Summary/Keyword: Canal system

Search Result 364, Processing Time 0.03 seconds

A STUDY OF THE ANATOMY OF MANDIBULAT MOLAR & THE EFFECT OF VARIOUS INSTRUMENTATION ON CORONAL FLARING (하악구치 근심근의 해부학적 형태와 근관확대방법이 Coronal flaring에 미치는 영향에 관한 연구)

  • Lee, Se-Jong;An, Byoung-Doo;Choi, Gi-Woon;Yim, Mi-Keoung
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.174-181
    • /
    • 1991
  • A model system was used which enabled the same root canal system to be measured before and after coronal flaring of 51 extracted mandibular molars. The concavity of the distal surface of the mesial root was measured and the amount of reduction was compared after coronal flaring using step-back flared preparation, Gates-Glidden dirll or ultrasonic system(Quick-$\varepsilon$) at the furcation and apical 3mm from the furcation. The results were as follows: 1. The mean concavity of mesial root of manchbular molar was $0.73{\pm}0.27mm$ at the bifurcation and $0.65{\pm}0.23mm$ at the 3.0mm apical from the bifurcation. 2. The thickness of the root canal wall of the mesiobuccal canal was $1.08{\pm}0.26mm$ at the bifurcation and $1.00{\pm}0.23mm$ at the 3.0mm apical from the bifurcation. 3. The thickness of the root canal wall of the mesiolingual was $1.09{\pm}0.21mm$ at the bifurcation and $0.98{\pm}0.29mm$ at the 3.0mm apical from the bifurcation. 4. In the amount of reduction at the furcation and at the 3.0mm apical from the furcation there was no statistically significant difference between the step-back preparation and Gates-Glidden drill preparation, and ultrasonic preparation(P>0.05).

  • PDF

COMPARISON OF THE INFLUENCE OF CANAL CURVATURE ON THE SEALING ABILITY OF LATERAL CONDENSATION AND SYSTEM BTM (측방가압법과 System BTM를 이용한 근관충전시 근관만곡도에 따른 폐쇄효과의 비교)

  • Lim, Dong-Yeul;Lee, Hee-Joo;Hur, Buck
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.482-489
    • /
    • 1999
  • The purpose of this study was to compare sealing ability between lateral condensation and continuous wave of condensation in depend of root canal curvature. In this study, we divided fifty-six human molar teeth into two group in depend of Schneider method, and then subdivided them into four experimental group (each group is composed of twelve teeth) by canal curvature and obturation method, and eight teeth were served as positive and negative controls. Specimens were prepared by Quantac 2000 series file and obturated by lateral condensation or System B. Specimens were immersed in india ink for 7 days, decalcified by 10% nitric acid, dehydrated by 75, 95 and 100% alcohol in order, cleared by methyl salicylate and then measured of dye penetration with stereomicroscope(${\times}6.5$ magnification) and Image Pro plus. The data were analyzed stastically by one-way ANOVA and Scheffe test. The data were as follows: 1. The mean leakage was $0.725{\pm}1.167$ for group A, $0.813{\pm}0.921$ for group B, $0.809{\pm}0.997$ for group C, $1.111{\pm}1.147$ for group D, but no significant difference among them(p>0.05). 2. Lateral condensation had better sealing ability than continuous wave of condensation, but no significant difference among them(p>0.05). 3. There was no significant difference between root canal curvature degree and microleakage(p>0.05).

  • PDF

Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser

  • Gulsen Kiraz;Bulem Ureyen Kaya;Mert Ocak;Muhammet Bora Uzuner;Hakan Hamdi Celik
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.36.1-36.15
    • /
    • 2023
  • Objectives: This study aimed to compare the effectiveness of a single-file reciprocating system (WaveOne Gold, WOG) and a multi-file rotary system (ProTaper Universal Retreatment, PTUR) in removing canal filling from severely curved canals and to evaluate the possible adjunctive effects of XP-Endo Finisher (XPF), the Self-Adjusting File (SAF), and an erbium, chromium: yttrium, scandium, gallium garnet (Er,Cr:YSGG) laser using microcomputed tomography (µCT). Materials and Methods: Sixty-six curved mandibular molars were divided into 2 groups based on the retreatment technique and then into 3 based on the supplementary method. The residual filling volumes and root canals were evaluated with µCT before and after retreatment, and after the supplementary steps. The data were statistically analyzed with the t-test, Mann-Whitney U test, analysis of covariance, and factorial analysis of variance (p < 0.05). Results: PTUR and WOG showed no significant difference in removing filling materials (p > 0.05). The supplementary techniques were significantly more effective than reciprocating or rotary systems only (p < 0.01). The supplementary steps showed no significant differences in canal filling removal effectiveness (p > 0.05), but XPF showed less dentin reduction than the SAF and Er,Cr:YSGG laser (p < 0.01). Conclusions: The supplementary methods significantly decreased the volume of residual filling materials. XPF caused minimal changes in root canal volume and might be preferred for retreatment in curved root canals. Supplementary approaches after retreatment procedures may improve root canal cleanliness.

In-depth morphological study of mesiobuccal root canal systems in maxillary first molars: review

  • Chang, Seok-Woo;Lee, Jong-Ki;Lee, Yoon;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.2-10
    • /
    • 2013
  • A common failure in endodontic treatment of the permanent maxillary first molars is likely to be caused by an inability to locate, clean, and obturate the second mesiobuccal (MB) canals. Because of the importance of knowledge on these additional canals, there have been numerous studies which investigated the maxillary first molar MB root canal morphology using in vivo and laboratory methods. In this article, the protocols, advantages and disadvantages of various methodologies for in-depth study of maxillary first molar MB root canal morphology were discussed. Furthermore, newly identified configuration types for the establishment of new classification system were suggested based on two image reformatting techniques of micro-computed tomography, which can be useful as a further 'Gold Standard' method for in-depth morphological study of complex root canal systems.

One-D Model Prediction of Pollutant Transport at a Canal Network (수로망에서의 오염물질 확산의 1차원 예측)

  • Lee, Jung-Lyul;Hsiang Wang
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.6 no.1
    • /
    • pp.51-60
    • /
    • 1994
  • A one-dimensional numerical model has been developed through a Lagragian formulation, which is applicable to advection and diffusion of dissolved matters in storages. The study was conducted to the pollutants released into a canal network in Burnt Store Isles, Punta Gorda, Florida. USA. The hydrodynamic model was developed by using an implicit finite difference scheme. In the computational domain, the network system consists of prismatic channels and storages. The finger canals and small tributaries ale treated as storages in the simplified flow network The numerical results show relatively good agreement with field experiments.

  • PDF

Formant frequency changes of female voice /a/, /i/, /u/ in real ear (실이에서 여자 음성 /ㅏ/, /ㅣ/, /ㅜ/의 포먼트 주파수 변화)

  • Heo, Seungdeok;Kang, Huira
    • Phonetics and Speech Sciences
    • /
    • v.9 no.1
    • /
    • pp.49-53
    • /
    • 2017
  • Formant frequencies depend on the position of tongue, the shape of lips, and larynx. In the auditory system, the external ear canal is an open-end resonator, which can modify the voice characteristics. This study investigates the effect of the real ear on formant frequencies. Fifteen subjects ranging from 22 to 30 years of age participated in the study. This study employed three corner vowels: the low central vowel /a/, the high front vowel /i/, and the high back vowel /u/. For this study, the voice of a well-educated undergraduate who majored in speech-language pathology, was recorded with a high performance condenser microphone placed in the upper pinna and in the ear canal. Paired t-test showed that there were significant difference in the formant frequencies of F1, F2, F3, and F4 between the free field and the real ear. For /a/, all formant frequencies decreased significantly in the real ear. For /i/, F2 increased and F3 and F4 decreased. For /u/, F1 and F2 increased, but F3 and F4 decreased. It seems that these voice modifications in the real ear contribute to interpreting voice quality and understanding speech, timbre, and individual characteristics, which are influenced by the shape of the outer ear and external ear canal in such a way that formant frequencies become centralized in the vowel space.

Endodontic management of mandibular first premolar with C-shaped canals by using cone-beam computed tomography and dental operating microscope (CBCT와 치과용 현미경을 이용한 C형 근관을 가지는 하악 제1소구치의 근관치료)

  • Chang, Hoon-Sang;Kim, Min-Jeong;Lee, Seok-Ryun;Hong, Sung-Ok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.324-328
    • /
    • 2014
  • Aberrant anatomy of mandibular premolars is very rare in Korean, but aberration can contribute the endodontic failure as it makes difficult to remove the irritants during cleaning and shaping procedure. This case report describes the successful root canal treatment of a rare mandibular first premolar with C-shaped root canal as using a cone-beam computed tomography to understand the internal shape of root canal system and a dental operating microscope to improve the magnification and illumination.

Assessment of water quality in an artificial urban canal: A case study of Songdo City in South Korea

  • Ahn, Jungkyu;Na, Yeji;Park, Sung Won
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.582-590
    • /
    • 2019
  • Currently, the waterfront facility was constructed in New Songdo City, South Korea. It has the various water leisure areas and especially an artificial urban canal with filtered seawater by re-circulating flow system. However, due to excessive amount of nutrients from seawater combined with complicated geometry, it is highly vulnerable to deterioration of water quality. In this study, flow characteristics and pollutant transport were analyzed with comprehensive numerical models, MIKE 3 FM and ECO-lab. Based on these numerical results, notable sampling points were selected for field measurements and comparison between modeling and measured results were conducted. In addition, the integrated water quality evaluation index, Water Quality Index was applied to analyze various water quality issues. We also set up scenarios to control the two kinds of water quality factors, dissolved oxygen (DO), and total phosphorus (TP). As a result, the effect of 20% reduction of TP was less than 10% and it was almost ineffective for a year but it was reduced by up to 40% in case of scenario which DO is increased by 20%. Therefore, it was recommended to control the DO concentration, usually by applying re-aeration facility, rather than TP in artificial urban canal with seawater.

Development of controlled releasing drug (CRD) for root canal disinfection

  • Bok, Young-Bin;Lee, Chan-Young;Lee, Doug-Youn;Kum, Kee-Youn
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.553-553
    • /
    • 2003
  • I. Objectives Endodontic disease is caused primarily by bacteria that interact with periradicular host from the root canal system. Chlorhexidine gluconate is known to effective to eliminate Enterococcus faecalis which resists to other intracanal medicaments. The aim of this in vitro study was to develop a slowly releasing root canal disinfectant using using chlorhexidine gluconate and chitoic acid. II. Materials and Methods Three different group were prepared with different drug release mechanism. In group A, paper points as used core material were loaded with 20% chlorhexidine gluconate.(omitted)

  • PDF

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone (네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력)

  • Choi, Seok-Dong;Jin, Myoung-Uk;Kim, Ki-Ok;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.446-453
    • /
    • 2004
  • The aim of this study was to evaluate the shaping abilities of four different rotary nickel-titanium instruments with anticurvature motion to prepare root canal at danger zone by measuring the change of dentin thickness in order to have techniques of safe preparation of canals with nickel-titanium files. Mesiobuccal and mesiolingual canals of forty mesial roots of extracted human lower molars were instrumented using the crown-down technique with ProFile, $GT^{TM}$ Rotary file, Quantec file and $ProTaper^{TM}$. In each root, one canal was prepared with a straight up-and-down motion and the other canal was with an anticurvature motion. Canals were instrumented until apical foramens were up to size of 30 by one operator. The muffle system was used to evaluate the root canal preparation. After superimposing the pre- and post-instrumentation canal. change in root dentin thickness was measured at the inner and outer sides of the canal at 1. 3, and 5 mm levels from the furcation. Data were analyzed using two-way ANOVA. Root dentin thickness at danger zone was significantly thinner than that at safe zone at all levels (p < 0.05). There was no significant difference in the change of root dentin thickness between the straight up-and-down and the anticurvature motions at both danger and safe zones in all groups (p > 0.05). ProTaper removed significantly more dentin than other files especially at furcal 3 mm level of danger and safe zones (p < 0.05) Therefore, it was concluded that anticurvature motion with nickel-titanium rotary instruments does not seem to be effective in danger zone of lower molars.