• Title/Summary/Keyword: Caliper System

Search Result 72, Processing Time 0.033 seconds

Fusion of Blockchain-IoT network to improve supply chain traceability using Ethermint Smart chain: A Review

  • George, Geethu Mary;Jayashree, LS
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.11
    • /
    • pp.3694-3722
    • /
    • 2022
  • In today's globalized world, there is no transparency in exchanging data and information between producers and consumers. However, these tasks experience many challenges, such as administrative barriers, confidential data leakage, and extensive time delays. To overcome these challenges, we propose a decentralized, secured, and verified smart chain framework using Ethereum Smart Contract which employs Inter Planetary File Systems (IPFS) and MongoDB as storage systems to automate the process and exchange information into blocks using the Tendermint algorithm. The proposed work promotes complete traceability of the product, ensures data integrity and transparency in addition to providing security to their personal information using the Lelantos mode of shipping. The Tendermint algorithm helps to speed up the process of validating and authenticating the transaction quickly. More so in this time of pandemic, it is easier to meet the needs of customers through the Ethermint Smart Chain, which increases customer satisfaction, thus boosting their confidence. Moreover, Smart contracts help to exploit more international transaction services and provide an instant block time finality of around 5 sec using Ethermint. The paper concludes with a description of product storage and distribution adopting the Ethermint technique. The proposed system was executed based on the Ethereum-Tendermint Smart chain. Experiments were conducted on variable block sizes and the number of transactions. The experimental results indicate that the proposed system seems to perform better than existing blockchain-based systems. Two configuration files were used, the first one was to describe the storage part, including its topology. The second one was a modified file to include the test rounds that Caliper should execute, including the running time and the workload content. Our findings indicate this is a promising technology for food supply chain storage and distribution.

High Resolution Borehole Acoustic Scanner (Televiewer) (고분해능 텔레뷰어 검층기법의 기능)

  • ;Schepers,R
    • The Journal of Engineering Geology
    • /
    • v.5 no.3
    • /
    • pp.277-288
    • /
    • 1995
  • Fracture detection has always been very attractive to the log, because it is important in many of our prospecting activities, e.g. in understanding the underground rock formation and also the fluid flow as a high permeability path. This paper demonstrates the use of high resolution borehole acoustic scanner for the detection of fractures. The tool, known as Televiewer, is the first acoustic borehole imaging system to use a focussed beam. The acoustic beams generated by a single transducer are sent toward the borehole wall, scanning the wall in a tight helix as the tool moves along the borehole. The amplitudes and travel times of the reflected signals are then measured, which produces the corresponding images. The highly resolved amplitude image allows to recognize various size of fractures and in addition to derive the rock strength from the image. Meanwhile, the travel time image itself can be directly converted to a precise caliper image, providing detailed information of deviations of the borehole shape. It also allows correction of and explanations for amplitude variations. Field measurements were carried Out at the Cheongyang study sites in Korea to illustrate the efficiency of the televiewer log.

  • PDF

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

A STUDY ON THE ANALYSIS OF OCCLUSAL CURVE OF THE NORMAL SUBJECTS (정상인의 교합 만곡 분석에 관한 연구)

  • Choi, Myung-Sik;Kay, Kee-Sung;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.95-122
    • /
    • 1990
  • This study was done to analyze the occlusal curve as one of the factors to be considered for maintenance of occlusal stability in the orthodontic and prosthodontic treatments. Sixty gnathological casts we.e obtained from 43 subjects with normal occlusion and 17 subjects with some of temporomandibular disorders. The occlusal surfaces of gnathologic casts were duplicated by using a Color kit SK-700 and tile reference points of X, Y coordinates were digitized by using the Summagraphic digitizer and 18AT computer system. The Z coordinates of cusp height were measured by 0.01mm measurable caliper. The mathematical computer program of least square method was used to analyze the occlusal curve arranged by three dimensional coordinates of X, Y, Z. The following results were obtained : 1. The occlusal curve of buccal and lingual cusp tips was fitted to the ellipse, and the occlusal curve of anterior teeth was fitted to a part of the circle in the analysis of conic sections. 2. The radius of Spee's curve showed individual differences, but was average 98.7mm in male subjects and 93.7mm in female subjects. 3. The radius fo Spee's curve according to the half of canine width showed the least coefficient of variation. 4. The radius of Spee's curve was not significantly relative to the lateral occlusal contacts on laterotrusion and the absence or presence of temporomandibular disorders. 5. The radius of Wilson's curve showed individual difference and the size of radius was followed by the order of 1st premolar, 2nd premolar, 2nd molar and 1st molar.

  • PDF

Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system (동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로)

  • Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

Fatigue Analysis for Electro-Mechanical Brake Caliper based on Eccentric Rotating Shaft (편심회전축 기반의 전기기계식 제동장치의 피로수명 해석)

  • Oh, Hyuck Keun;Beak, Seung-Koo;Jeon, Chang-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.596-603
    • /
    • 2020
  • 'Electro-Mechanical Brake (EMB) is a novel braking system for automobiles and railway vehicles, and research in this area is actively underway. The current braking system for railway vehicles generates a braking force using a pneumatic cylinder, but the EMB system generates the force through a combination of an electric motor and gears. In this study, the design of an EMB system that meets the domestic standards was conducted through the finite element modeling and fatigue analysis of an eccentric rotating shaft-based EMB system capable of generating a high clamping force. At this time, to improve the accuracy of fatigue analysis, three types of fatigue test specimens, which were subjected to the same heat treatment as the materials used in the prototype, were produced, and the fatigue tests were performed for each material. The fatigue properties (S-N curves) were obtained from the fatigue test results for each material and reflected in the analysis model. The results of fatigue analysis confirmed that the design of the EMB prototype could satisfy the maximum commercial braking/relaxation of 530,000 times, which was the endurance life condition for domestic railway vehicles. In addition, based on this design, a prototype will be manufactured, and endurance testing will be completed to demonstrate the durability characteristics of the developed prototype.

Accuracy and Precision of Three-dimensional Imaging System of Children's Facial Soft Tissue (소아 얼굴 연조직의 3차원 입체영상의 정확성 및 재현성 평가)

  • Choi, Kyunghwa;Kim, Misun;Lee, Koeun;Nam, Okhyung;Lee, Hyo-seol;Choi, Sungchul;Kim, Kwangchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.17-24
    • /
    • 2020
  • The purpose of this study was to evaluate the accuracy and precision of the three-dimensional (3D) imaging system of children's facial soft tissue by comparing linear measurements. The subjects of the study were 15 children between the ages of 7 and 12. Twenty-three landmarks were pointed on the face of each subject and 16 linear measurements were directly obtained 2 times using an electronic caliper. Two sets of 3D facial images were made by the 3D scanner. The same 16 measurements were obtained on each 3D image. In the accuracy test, the total average difference was 0.9 mm. The precision of 3D photogrammetry was almost equivalent to that of direct measurement. Thus, 3D photogrammetry by the 3D scanner in children had sufficient accuracy and precision to be used in clinical setting. However, the 3D imaging system requires the subject's compliance for exact images. If the clinicians provide specific instructions to children while obtaining 3D images, the 3D device is useful for investigating children's facial growth and development. Also the device can be a valuable tool for evaluating the results of orthodontic and orthopedic treatments.

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

A Design Method of Three-phase IPMSM and Clamping Force Control of EMB for High-speed Train (고속철도차량의 EMB 적용을 위한 3상 IPMSM의 설계 및 제동압부력 제어)

  • Baek, Seung-Koo;Oh, Hyuck-Keun;Kwak, Min-ho;Kim, Seog-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.578-585
    • /
    • 2018
  • This paper proposes a design method for a 3-phase interior permanent magnet synchronous motor (IPMSM) and clamping force control method for an electro-mechanical brake (EMB) using co-simulation for a high-speed train (HST). A traditional pneumatic brake system needs much space for the compressor, brake reservoir, and air pipe. However, an EMB system uses up to 50% less space due to the use of a motor and electric wires for controlling the brake caliper. In addition, it can reduce the latency time for brake control because of the fast response and precise control. A train that has many brakes is advantageous for safety because of the control by sharing the braking force. In this paper, a driving method for a cam-shaft-type EMB is modeled. It is different from the ball-screw-type brakes that are widely used in automobiles. In addition, a co-simulation method is proposed using JMAG and Matlab/Simulink. The IPMSM was designed and analyzed with the JMAG tool, and the control system was simulated using Matlab/Simulink. The effectiveness of the co-simulation results of the mechanical clamping force and braking force was verified by comparison with the clamping force specifications of a HEMU-430X HST.

Analysis of the Effect of Pavement Crack Depth of the Cavity Management Grade (포장 균열 깊이가 공동 관리 등급에 미치는 영향 분석)

  • Park, Jeong Jun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.449-457
    • /
    • 2020
  • Purpose: The Seoul Metropolitan Government classifies the cavity risks into emergency, priority, general, and observation grades in consideration of the cavity size, asphalt pavement thickness, and pavement depth based on the cavity management grade criteria of Seoul. In this study, the depth of cracking was measured at 17 cracks identified by checking the pavement condition of the cavity at 265 cavities found in the 2019 cavity investigation service. Method: In the first phase, crack width and depth were measured using a vernier caliper, taper gauge, and depth gauge to check the cracks of the identified cavities. In the second phase, the location of the largest crack in the upper road surface was confirmed, and A.C. was drilled to further measure the crack depth. Results: As a result, the cavity management level was raised in nine of the 17 test cavity identified. Therefore, in case of emergency and priority recovery, the grade should be adjusted according to the depth of pavement crack and the thickness of residual A.C. pavement. Conclusion: In the case of cracks in the upper part of the cavity, the crack progression must be determined through the perforation and the remaining asphalt concrete thickness must be determined to determine the cavity grade.