• 제목/요약/키워드: Caliper System

검색결과 72건 처리시간 0.032초

Fusion of Blockchain-IoT network to improve supply chain traceability using Ethermint Smart chain: A Review

  • George, Geethu Mary;Jayashree, LS
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권11호
    • /
    • pp.3694-3722
    • /
    • 2022
  • In today's globalized world, there is no transparency in exchanging data and information between producers and consumers. However, these tasks experience many challenges, such as administrative barriers, confidential data leakage, and extensive time delays. To overcome these challenges, we propose a decentralized, secured, and verified smart chain framework using Ethereum Smart Contract which employs Inter Planetary File Systems (IPFS) and MongoDB as storage systems to automate the process and exchange information into blocks using the Tendermint algorithm. The proposed work promotes complete traceability of the product, ensures data integrity and transparency in addition to providing security to their personal information using the Lelantos mode of shipping. The Tendermint algorithm helps to speed up the process of validating and authenticating the transaction quickly. More so in this time of pandemic, it is easier to meet the needs of customers through the Ethermint Smart Chain, which increases customer satisfaction, thus boosting their confidence. Moreover, Smart contracts help to exploit more international transaction services and provide an instant block time finality of around 5 sec using Ethermint. The paper concludes with a description of product storage and distribution adopting the Ethermint technique. The proposed system was executed based on the Ethereum-Tendermint Smart chain. Experiments were conducted on variable block sizes and the number of transactions. The experimental results indicate that the proposed system seems to perform better than existing blockchain-based systems. Two configuration files were used, the first one was to describe the storage part, including its topology. The second one was a modified file to include the test rounds that Caliper should execute, including the running time and the workload content. Our findings indicate this is a promising technology for food supply chain storage and distribution.

고분해능 텔레뷰어 검층기법의 기능 (High Resolution Borehole Acoustic Scanner (Televiewer))

  • 김증열
    • 지질공학
    • /
    • 제5권3호
    • /
    • pp.277-288
    • /
    • 1995
  • 최근, 암반내에 형성된 절리 및 단층에 대한 정확한 규명은 무엇보다 암반분류 내지 암반내 용질유동연구에어 대단히 중요한 과제로 되고 있다. 본 연구에서 소개된 텔레뷰어 검층장치는 주사되는 초음파를 초점화함으로서 절리상태를 고분해능으로 파악할 수 있는 기능을 갖고 있다. 즉, 초음파 발생원이 시추공 축상에서 선회하는 동안 시추공내벽으로 조밀하게 초음파빔을 주사하고 그로 인해 반사되는 초음파의 $\circled1$ 진폭변화는 바로 절리 및 단층의 크기, 경사, 및 방향은 물론 상대적인 암석강도변화도 정확하게 추출하게 하며, $\circled2$ 주시변화는 바로 고분해능 공경검층기능을 대변하게 되어 시추공 내벽상태 내지 암석의 응력장 분포도 쉽게 판단하게 하는 것이다. 본 논문은 국내 청양군 실험시추공에서 얻게 된 텔러뷰어 현장탐사결과를 예시함으로써 텔레뷰어의 다양한 응용성을 입증하고 있다.

  • PDF

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

정상인의 교합 만곡 분석에 관한 연구 (A STUDY ON THE ANALYSIS OF OCCLUSAL CURVE OF THE NORMAL SUBJECTS)

  • 최명식;계기성;강동완
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.95-122
    • /
    • 1990
  • This study was done to analyze the occlusal curve as one of the factors to be considered for maintenance of occlusal stability in the orthodontic and prosthodontic treatments. Sixty gnathological casts we.e obtained from 43 subjects with normal occlusion and 17 subjects with some of temporomandibular disorders. The occlusal surfaces of gnathologic casts were duplicated by using a Color kit SK-700 and tile reference points of X, Y coordinates were digitized by using the Summagraphic digitizer and 18AT computer system. The Z coordinates of cusp height were measured by 0.01mm measurable caliper. The mathematical computer program of least square method was used to analyze the occlusal curve arranged by three dimensional coordinates of X, Y, Z. The following results were obtained : 1. The occlusal curve of buccal and lingual cusp tips was fitted to the ellipse, and the occlusal curve of anterior teeth was fitted to a part of the circle in the analysis of conic sections. 2. The radius of Spee's curve showed individual differences, but was average 98.7mm in male subjects and 93.7mm in female subjects. 3. The radius fo Spee's curve according to the half of canine width showed the least coefficient of variation. 4. The radius of Spee's curve was not significantly relative to the lateral occlusal contacts on laterotrusion and the absence or presence of temporomandibular disorders. 5. The radius of Wilson's curve showed individual difference and the size of radius was followed by the order of 1st premolar, 2nd premolar, 2nd molar and 1st molar.

  • PDF

동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로 (Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

편심회전축 기반의 전기기계식 제동장치의 피로수명 해석 (Fatigue Analysis for Electro-Mechanical Brake Caliper based on Eccentric Rotating Shaft)

  • 오혁근;백승구;전창성
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.596-603
    • /
    • 2020
  • 전기기계식 제동장치(EMB : Electro-Mechanical Brake)는 자동차 및 철도차량의 차세대 제동장치로서 현재 연구가 활발히 진행되고 있다. 현재의 철도차량용 제동장치는 공압 실린더를 이용하여 제동 압부력을 발생시키나 전기기계식 제동장치 (EMB)에서는 전기 모터 및 기어와의 조합을 통하여 압부력을 발생시킨다. 본 연구에서는 고압부력 발생이 가능한 편심회전축 기반의 전기기계식 제동장치에 대한 유한요소 모델링 및 내구 수명해석을 통하여 국내 기준에 부합하는 전기기계식 제동장치의 설계를 진행하였다. 이때 내구수명해석의 정확도를 향상하기 위하여 시제품에 사용되는 소재와 동일한 열처리 등을 거친 피로시험 시편을 3종을 제작하여 소재별로 피로시험을 진행하였다. 각각의 소재에 대한 피로시험 결과로부터 피로물성치(응력-수명 선도)를 획득하여 해석모델에 반영하였다. 피로해석 결과로부터 EMB 시제품의 설계가 국내 철도차량용 내구수명 조건인 상용최대 제동/완해 53 만회를 만족할 수 있음을 확인하였다. 또한, 이 설계를 바탕으로 시제품을 제작하고 내구시험을 완료하여 개발된 시제품의 내구성 특성을 입증할 계획이다.

소아 얼굴 연조직의 3차원 입체영상의 정확성 및 재현성 평가 (Accuracy and Precision of Three-dimensional Imaging System of Children's Facial Soft Tissue)

  • 최경화;김미선;이고은;남옥형;이효설;최성철;김광철
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.17-24
    • /
    • 2020
  • 이 연구의 목적은 소아 얼굴 연조직의 선형 길이를 비교하여 삼차원 입체영상의 정확성과 재현성을 평가하는 것이다. 연구는 7 - 12세 아동 15명을 대상으로 하였다. 환자의 안모에 23개의 계측 점을 표시하고, 전자 캘리퍼를 이용하여 16 개의 선형길이를 직접 2번 계측하였다. 3차원(3D) 스캐너를 이용하여 2개의3D 얼굴 영상을 만들었으며, 직접계측과 동일한 16개의 선형 길이를 계측하였다. 연구결과 정확성 평가에서 전체 평균 차이 값은 0.9 mm였다. 3D 영상의 재현성은 직접계측의 재현성과 거의 유사한 정도로 나타났다. 이에 따라 이 3D 영상장비는 소아에서 임상적으로 충분한 정확성과 재현성을 가지고 있었다. 3D 영상 시스템은 정확한 이미지를 위하여 대상의 협조가 필요하다. 소아의 정확한 3D영상을 얻기 위한 구체적인 지시사항을 바탕으로 촬영을 한다면, 이 3D 영상 장비는 향후 소아의 성장과 발달을 조사하고, 소아교정치료에서 결과를 평가하는데 유용하게 사용될 수 있을 것이다.

호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구 (A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE)

  • 조수미;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

고속철도차량의 EMB 적용을 위한 3상 IPMSM의 설계 및 제동압부력 제어 (A Design Method of Three-phase IPMSM and Clamping Force Control of EMB for High-speed Train)

  • 백승구;오혁근;곽민호;김석원
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.578-585
    • /
    • 2018
  • 본 논문은 고속철도차량에 전기기계제동장치(EMB : Electric Mechanical Brake)를 적용하기 위한 주요 구성품인 3상 매입형영구자석동기전동기(IPMSM : Interior Permanent Magnet Synchronous Motor)의 설계방법과 이를 이용한 인버터 제어시스템의 압부력제어 시뮬레이션 방법을 제안한다. 최근 자동차에서 주로 사용하는 유압식 제동장치는 유압을 발생시키기 위해 필요한 오일류와 유압 라인의 관리, 유지보수성 및 유압펌프의 동작으로 인한 효율성 등이 문제로 제기되면서 EMB에 대한 관심이 높아지고 있으나 비용증가 및 안전측면의 보완이 지속적으로 요구되고 있다. 공압식 제동장치를 주로 사용하는 철도차량은 EMB 시스템을 적용할 경우 차량 하부에 큰 공간을 차지하는 공기압축기, 제동공기통 및 연결 배관 등의 부품이 필요하지 않으므로 50% 이상의 소형화가 가능하며 인버터를 적용한 전동기 구동방식으로 인하여 상대적으로 빠른 응답속도와 정밀제어를 통해 공주거리를 단축시킬 수 있는 장점을 갖는다. 또한, 철도차량은 다수의 제동장치가 제동력을 분담하는 구조로 설계되어 자동차와 비교하여 EMB 적용이 안전측면에서 유리하다. 본 논문에서는 JMAG을 활용하여 고속철도의 제동 캘리퍼와 제동력 출력에 적합한 모터설계 및 전자계해석을 수행하였다. 제동 압부력 제어 시뮬레이션을 위해 기계구동부는 기존 EMB 시스템에 주로 적용된 볼스크류 형태의 동작방식과는 달리 고속철도차량에 적용된 편심축 회전을 이용한 구동방식으로 모델링하였다. IPMSM 제어를 통한 제동압부력 및 제동력 출력결과는 Matlab/Simulink를 활용하여 JMAG의 IPMSM 모델과 co-simulation을 통해 보였으며 결과의 타당성은 차세대고속철도(HEMU-430X)의 제동사양과의 비교를 통해 검증하였다.

포장 균열 깊이가 공동 관리 등급에 미치는 영향 분석 (Analysis of the Effect of Pavement Crack Depth of the Cavity Management Grade)

  • 박정준
    • 한국재난정보학회 논문집
    • /
    • 제16권3호
    • /
    • pp.449-457
    • /
    • 2020
  • 연구목적:서울시는 공동관리 등급 기준에 따라 공동의 규모, 아스팔트포장 두께, 포장면의 균열깊이를 고려하여 긴급, 우선, 일반, 관찰등급으로 공동의 위험도를 분류하고 있다. 본 연구에서는 2019년 서울시 공동조사용역에서 발견된 265개소의 공동의 상부 포장상태를 확인하여 포장균열이 확인된 17개소에 대하여 균열깊이를 측정하였다. 연구방법: 1차에서는 확인된 공동의 균열 확인을 위하여 버니어 캘리퍼스, 테이퍼 게이지, 깊이 게이지를 활용하여 균열 폭 및 깊이를 측정하였다. 2차에서는 상부 노면에서 가장 크게 균열이 발생한 위치를 확인하여 아스콘을 천공 후 균열 깊이를 추가로 측정하였다. 연구결과:확인된 시험공동 17개소 중 9개소에서 공동 관리 등급이 상향 조정되었다. 따라서, 긴급복구와 우선복구의 경우에는 포장 균열 깊이와 잔여 아스팔트 콘크리트 포장 두께에 따라 등급 조정이 필요하다. 결론:공동 상부에 균열이 발생한 경우는 천공을 통하여 균열 진행 상태를 파악하고 잔여 아스팔트 콘크리트 두께를 확인하여 공동등급을 결정해야한다.