• Title/Summary/Keyword: Calibration frame

Search Result 108, Processing Time 0.028 seconds

Statistical analysis for RMSE of 3D space calibration using the DLT (DLT를 이용한 3차원 공간검증시 RMSE에 대한 통계학적 분석)

  • Lee, Hyun-Seob;Kim, Ky-Hyeung
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study was to design the method of 3D space calibration to reduce RMSE by statistical analysis when using the DLT algorithm and control frame. Control frame for 3D space calibration was consist of $1{\times}3{\times}2m$ and 162 contort points adhere to it. For calculate of 3D coordination used two methods about 2D coordination on image frame, 2D coordinate on each image frame and mean coordination. The methods of statistical analysis used one-way ANOVA and T-test. Significant level was ${\alpha}=.05$. The compose of methods for reduce RMSE were as follow. 1. Use the control frame composed of 24-44 control points arranged equally. 2. When photographing, locate control frame to center of image plane(image frame) o. use the lens of a few distortion. 3. When calculate of 3D coordination, use mean of 2D coordinate obtainable from all image frames.

Calibration of Structured Light Vision System using Multiple Vertical Planes

  • Ha, Jong Eun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.438-444
    • /
    • 2018
  • Structured light vision system has been widely used in 3D surface profiling. Usually, it is composed of a camera and a laser which projects a line on the target. Calibration is necessary to acquire 3D information using structured light stripe vision system. Conventional calibration algorithms have found the pose of the camera and the equation of the stripe plane of the laser under the same coordinate system of the camera. Therefore, the 3D reconstruction is only possible under the camera frame. In most cases, this is sufficient to fulfill given tasks. However, they require multiple images which are acquired under different poses for calibration. In this paper, we propose a calibration algorithm that could work by using just one shot. Also, proposed algorithm could give 3D reconstruction under both the camera and laser frame. This would be done by using newly designed calibration structure which has multiple vertical planes on the ground plane. The ability to have 3D reconstruction under both the camera and laser frame would give more flexibility for its applications. Also, proposed algorithm gives an improvement in the accuracy of 3D reconstruction.

Camera calibration parameters estimation using perspective variation ratio of grid type line widths (격자형 선폭들의 투영변화비를 이용한 카메라 교정 파라메터 추정)

  • Jeong, Jun-Ik;Choi, Seong-Gu;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.30-32
    • /
    • 2004
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as lens distortion, focal length, scale factor, pose, orientations, and distance. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1, 2, 3, 4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. The average scale factor tends to fluctuate with small variation and makes distance error decrease. Compared with classical methods that use stereo camera or two or three orthogonal planes, the proposed method is easy to use and flexible. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF

Kinematic Calibration of a Cartesian Parallel Manipulator

  • Kim, Han-Sung
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.3
    • /
    • pp.453-460
    • /
    • 2005
  • In this paper, a prototype Cartesian Parallel Manipulator (CPM) is demonstrated, in which a moving platform is connected to a fixed frame by three PRRR limbs. Due to the orthogonal arrangement of the three prismatic joints, it behaves like a conventional X-Y-Z Cartesian robot. However, because all the linear actuators are mounted at the fixed frame, the manipulator may be suitable for applications requiring high speed and accuracy. Using a geometric method and the practical assumption that three revolute joint axes in each limb are parallel to one another, a simple forward kinematics for an actual model is derived, which is expressed in terms of a set of linear equations. Based on the error model, two calibration methods using full position and length measurements are developed. It is shown that for a full position measurement, the solution for the calibration can be obtained analytically. However, since a ball-bar is less expensive and sufficiently accurate for calibration, the kinematic calibration experiment on the prototype machine is performed by using a ball-bar. The effectiveness of the kinematic calibration method with a ball-bar is verified through the well­known circular test.

The Camera Calibration Parameters Estimation using The Projection Variations of Line Widths (선폭들의 투영변화율을 이용한 카메라 교정 파라메터 추정)

  • Jeong, Jun-Ik;Moon, Sung-Young;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2372-2374
    • /
    • 2003
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as focal length, scale factor, pose, orientations, and distance. But, radial lens distortion is not modeled. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1,2,3,4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF

A study on the transformation of EO parameters using Boresight calibration (Boresight calibration을 이용한 외부표정요소 산출에 관한 연구)

  • 박수영;윤여상;김준철;정주권;주영은
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.129-134
    • /
    • 2003
  • Mobile Mapping System needs system calibration of multi sensors. System calibration is defined as determination of spatial and rotational offsets between the sensors. Especially, EO parameters of GPS/INS require knowledge of the calibration to camera frame. The calibration parameters must be determined with the highest achievable accuracy in order to get 3D coordinate points in stereo CCD images. This study applies Boresight calibration for the calibration between GPS/INS and camera, and estimates the Performance of the calibration.

  • PDF

3D Reconstruction using the Key-frame Selection from Reprojection Error (카메라 재투영 오차로부터 중요영상 선택을 이용한 3차원 재구성)

  • Seo, Yung-Ho;Kim, Sang-Hoon;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.38-46
    • /
    • 2008
  • Key-frame selection algorithm is defined as the process of selecting a necessary images for 3D reconstruction from the uncalibrated images. Also, camera calibration of images is necessary for 3D reconstuction. In this paper, we propose a new method of Key-frame selection with the minimal error for camera calibration. Using the full-auto-calibration, we estimate camera parameters for all selected Key-frames. We remove the false matching using the fundamental matrix computed by algebraic deviation from the estimated camera parameters. Finally we obtain 3D reconstructed data. Our experimental results show that the proposed approach is required rather lower time costs than others, the error of reconstructed data is the smallest. The elapsed time for estimating the fundamental matrix is very fast and the error of estimated fundamental matrix is similar to others.

A development of the simple camera calibration system using the grid type frame with different line widths (다른 선폭들로 구성된 격자형 교정판을 이용한 간단한 카메라 교정 시스템의 개발)

  • 정준익;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.371-374
    • /
    • 1997
  • Recently, the development of computer achieves a system which is similar to the mechanics of human visual system. The 3-dimensional measurement using monocular vision system must be achieved a camera calibration. So far, the camera calibration technique required reference target in a scene. But, these methods are inefficient because they have many calculation procedures and difficulties in analysis. Therefore, this paper proposes a native method that without reference target in a scene. We use the grid type frame with different line widths. This method uses vanishing point concept that possess a rotation parameter of the camera and perspective ration that perspect each line widths into a image. We confirmed accuracy of calibration parameter estimation through experiment on the algorithm with a grid paper with different line widths.

  • PDF

A New Hand-eye Calibration Technique to Compensate for the Lens Distortion Effect (렌즈왜곡효과를 보상하는 새로운 Hand-eye 보정기법)

  • Chung, Hoi-Bum
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.596-601
    • /
    • 2000
  • In a robot/vision system, the vision sensor, typically a CCD array sensor, is mounted on the robot hand. The problem of determining the relationship between the camera frame and the robot hand frame is refered to as the hand-eye calibration. In the literature, various methods have been suggested to calibrate camera and for sensor registration. Recently, one-step approach which combines camera calibration and sensor registration is suggested by Horaud & Dornaika. In this approach, camera extrinsic parameters are not need to be determined at all configurations of robot. In this paper, by modifying the camera model and including the lens distortion effect in the perspective transformation matrix, a new one-step approach is proposed in the hand-eye calibration.

  • PDF

A study on the calibration parameter estimation of camera using square calibration frame (정방형 교정 frame을 이용한 카메라의 교정 파라메타 추정에 관한 연구)

  • 최성구;노도환
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.7
    • /
    • pp.127-137
    • /
    • 1996
  • The 3-dimensional measurement using stereo vision system must achieve a camera calibration. So far, the 3-dimensional calibration technique that uses two-dimensional grid papar and a non-linear least square method has been developed and tested. But, this method is inefficient because it has many calculation procedure and a non-linear analysis. Therefore, this paper proposed the projective geometric method which produced the calibration parameter by vanishing point. The vanishing point is producted by a cross ratio and a parallel line pairs. The results of the computer simulation show utility of the proposed method.

  • PDF