• Title/Summary/Keyword: Calibration chamber system

Search Result 78, Processing Time 0.023 seconds

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs) (광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정)

  • Im, In-Chul;Yu, Yun-Sik;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • This study used the optically stimulated luminescence dosimeters (OSLDs), recently, received the revaluation of usefulness in vivo dosimetry, and the diode detecters to measure the skin dose of patient with the rectal cancer. The measurements of dose delivered were compared with the planned dose from the treatment planning system (TPS). We evaluated the clinical application of OSDs in radiotherapy. We measured the calibration factor of OSLDs and used the percent depth dose to verified, also, we created the three point of surface by ten patients of rectal cancer to measured. The calibration factors of OSLD was 1.17 for 6 MV X-ray and 1.28 for 10 MV X-ray, demonstrating the energy dependency of X-ray beams. Comparison of surface dose measurement using the OSLDs and diode detectors with the planned dose from the TPS, The skin dose of patient was increased 1.16 ~ 2.83% for diode detectors, 1.36 ~ 2.17% for OSLDs. Especially, the difference between planned dose and the delivery dose was increased in the perineum, a skin of intense flexure region, and the OSLDs as a result of close spacing of measuring a variate showed a steady dose verification than the diode detecters. Therefore, on behalf of the ionization chamber and diode detecters, OSLDs could be applied clinically in the verification of radiation dose error and in vivo dosimety. The research on the dose verification of the rectal cancer in the around perineal, a surface of intense flexure region, suggest continue to be.

A Micro-robotic Platform for Micro/nano Assembly: Development of a Compact Vision-based 3 DOF Absolute Position Sensor (마이크로/나노 핸들링을 위한 마이크로 로보틱 플랫폼: 비전 기반 3자유도 절대위치센서 개발)

  • Lee, Jae-Ha;Breguet, Jean Marc;Clavel, Reymond;Yang, Seung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.125-133
    • /
    • 2010
  • A versatile micro-robotic platform for micro/nano scale assembly has been demanded in a variety of application areas such as micro-biology and nanotechnology. In the near future, a flexible and compact platform could be effectively used in a scanning electron microscope chamber. We are developing a platform that consists of miniature mobile robots and a compact positioning stage with multi degree-of-freedom. This paper presents the design and the implementation of a low-cost and compact multi degree of freedom position sensor that is capable of measuring absolute translational and rotational displacement. The proposed sensor is implemented by using a CMOS type image sensor and a target with specific hole patterns. Experimental design based on statistics was applied to finding optimal design of the target. Efficient algorithms for image processing and absolute position decoding are discussed. Simple calibration to eliminate the influence of inaccuracy of the fabricated target on the measuring performance also presented. The developed sensor was characterized by using a laser interferometer. It can be concluded that the sensor system has submicron resolution and accuracy of ${\pm}4{\mu}m$ over full travel range. The proposed vision-based sensor is cost-effective and used as a compact feedback device for implementation of a micro robotic platform.

Determination of Failure Mechanism of Slope Calibration Chamber Tests Using Rainfall Simulation (I) (인공강우에 의한 모형토조사면의 붕괴메카니즘 결정 (I))

  • Jeong, Ji-Su;Jung, Chun-Gyo;Lee, Jong-In;Lee, Seong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.27-34
    • /
    • 2011
  • This study analyzes the determination of slope failure model due to changes in ground condition followed by heavy rainfall. With a simulated rainfall system, the movement of a slope from the rainfall penetrating the unsaturated soil is investigated with respect to various conditions of pore-water pressure, earth pressure, and moisture content, considering rainfall duration and permeability. As a result of the experiment, under the persistent precipitation of 50mm/h, pore-water pressure of weathered granite soil started increasing from the upper position of the slope, and then the pressure increased in middle and bottom portion of it in timely manner. In case of the pore-water pressure of the standard soil, the pressure increased from the middle and bottom portion, and the cause of the different order is suspected to be the difference in permeability between the standard soil and the weathered granite soil. As an outcome, though the result may vary by each foundation, there exists a danger of slope failure not only when the cumulative rainfall is more than 120 mm but also when the saturation level amounts to 60~75%.

The Distribution of Nitrogen and the Decomposition Rate of Organic Nitrogen in the Youngsan River and the Sumjin River, Korea (영산강과 섬진강 수계의 질소 분포와 유기질소 분해속도)

  • Kim, Jihye;Kim, Bomchul;Shin, Myoungsun;Kim, Jaiku;Jung, Sungmin;Lee, Yunkyoung;Park, Juhyun
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.142-150
    • /
    • 2009
  • The distribution of organic nitrogen and its decomposition rate were studied in the Youngsan River and the Sumjin River system in Korea. Samples were conducted seasonally in June, August, December of 2006, and February of 2007. Collected samples were incubated for 20 days in a dark chamber ($20{\pm}1^{\circ}C$) and analyzed the changes of nitrogen form (particulate organic nitrogen, dissolved organic nitrogen, ammonia, nitrite, and nitrate). The mean total nitrogen (TN) concentration in the Youngsan River and the Sumjin River were $2.62mgN{\cdot}L^{-1}$ and $1.53mgN{\cdot}L^{-1}$, respectively. TN comprised of 65% DIN and 35% ON. The decomposition coefficients of organic nitrogen were also determined by two different fitting models. The decomposition rates of nitrogen species (TON, LPON, LDON, ${NH_4}^+$ and ${NO_2}^-$) ranged from 0.024 to $1.043day^{-1}$ in the Youngsan River and 0.008 to $0.693day^{-1}$ in the Sumjin River, respectively. The result of this study can give a guide to the selection of parameters in the calibration processes of water quality models.

Initial Excess Pore Pressure Induced by Cone Penetration in Normally Consolidated Clays (정규압밀점토에서의 피에조 콘 관입에 의한 과잉간극수압에 대한 연구)

  • 임형덕;이우진;김대규
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.1
    • /
    • pp.151-161
    • /
    • 2003
  • In this study, an interpretation method is proposed to evaluate the stress conditions, including individual excess pore pressure components ($\Delta{u}_{oct}$/ and $\Delta{u}_{shear}$), of normally consolidated clay elements adjacent to the cone face. It is assumed that the stress path of triaxial compression is representative f3r that of the soil element and the soil is elastic-perfectly plastic material. The proposed method is applied to the results of miniature piezocone tests conducted at Louisiana State University calibration chamber system. Based on the results of interpretation, it was found that the ratio of $\Delta{u}_{oct}$/ $\Delta{u}$and $\Delta{u}_{shear}$/$\Delta{u}$ estimated by the proposed method is affected only by the pore pressure parameter. The proposed method gives consistent and reliable values of $\Delta{u}_{oct}$/ $\Delta{u}$and $\Delta{u}_{shear}$/$\Delta{u}$ compared with early works, whereas those obtained by other solutions are significantly dependent on the accuracy in estimating soil properties such as undrained shear strength and rigidity index.

Estimation of Coefficient of Consolidation Using Piezocone Dissipation Test in Normally Consolidated Clays (정규압밀점토에서의 피에조 콘 소산시험을 이용한 수평압밀계수의 산정)

  • 임형덕;이우진;김대규
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.145-154
    • /
    • 2003
  • In this study, the variation in excess pore pressure during dissipation is estimated by using successive cavity expansion theory and finite difference technique based on axisymmetric uncoupled linear consolidation theory with separate consideration of magnitude and initial distribution $\Delta{u}_{oct}$induced by changes of octahedral normal stress, and $\Delta{u}_{shear}$ induced by changes of octahedral shear stress. The coefficient of consolidation is also estimated by trial and error procedure until the predicted dissipation curve matches the measured curve at a typical degree of dissipation. The proposed method is applied to the results of miniature piezocone tests at Louisiana State University calibration chamber system. Based on the results of interpretation and the comparison with experimental measurements and those from other solutions, the prediction dissipation curves show a good match with those measured during dissipation tests and the values of coefficient of consolidation estimated by proposed method are more close to the range of laboratory measurements than those of other theories.

A Study on Numerical Technique of the Hardened Grout Formed by Grouting (약액주입 시 형성된 고결체의 수치해석 기법 연구)

  • Lee, Jong-Hwi;Chun, Byung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.6
    • /
    • pp.27-37
    • /
    • 2011
  • Recently, pressure grouting is widely being used in construction site for strength improvement of ground and water proof, reinforcement and so on. It is necessarily required to estimate an appropriate injection pressure and injection time for economical and reasonable construction in the site through the size and shape of the hardened grout measured according to ground condition. However, sampling for the hardened grout is time-consuming and needs high cost on preliminary test in the site. The system which could predict the size and shape of the hardened grout does not exist until now. Thus, numerical method based on VOF method and porous model was used for the calibration chamber injection test with injection pressure (50 kPa, 100 kPa, 150 kPa) in this study. The results indicate that the numerical technique based on VOF method and porous model among CFD analysis is expected to be a basic study for the prediction of the behavior and solidification of pressure grouting.

Fuel Concentration Measurements by Laser Rayleigh Scattering (레이저 Rayleigh 산란을 이용한 연료농도 계측시 잡음원인과 대책)

  • Kwon, Soon-Tae;Lee, Jae-Won;Park, Chan-Jun;Ohm, In-Young
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.189-197
    • /
    • 2008
  • In this study, a system to measure continuously the fuel concentration in a steady flow rig on the basis of Rayleigh scattering is presented. The system can be employed to measure both the temporal and the spatial distribution. Also, it is possible to calibrate the system for the measurement of accurate absolute concentration. Firstly, the system was tested at a calibration chamber for the determination of scattering cross section from propane, butane, acetylene, Freon-12 and Genetron 143a. After this, the system was adapted to a steady flow rig to measure the temporal and spatial fuel concentration. The rig is composed of cylinder head, intake manifold, injector, and transparent cylinder which can simulate internal combustion engine. To cope with the interference of Mie scattering, which is main obstacle of the measuring concentration with Rayleigh scattering, a hardware filter was installed for reducing the number density of particles. Furthermore a software filter was developed, which is based on the rise time and the time constant of the photomultiplier-amplifier system. In addition, background noisy was reduced by adjusting the optical array and applying the pin hall and beam trap. The results show that LRS can provide useful information about concentration field and the software filter is very effective method to remove Mie interference.

Soil CO2 Efflux Dynamics in Response to Fertilization in Pinus densiflora and Quercus variabilis Stands (소나무와 굴참나무 임분의 시비에 따른 토양 CO2 방출 동태)

  • Baek, Gyeongwon;Kim, Choonsig
    • Journal of Korean Society of Forest Science
    • /
    • v.109 no.3
    • /
    • pp.271-280
    • /
    • 2020
  • This study compared soil CO2 efflux rates after fertilization, in Pinus densiflora and Quercus variabilis stands. Compound fertilizers were applied to the forest floor in March 2016, following a one-year calibration period (from March 2015 to February 2016). In situ soil CO2 efflux rates were measured every month during the two-year study periods, using an infrared gas analyzer with a closed chamber system. Mean annual soil CO2 efflux rates were higher following fertilizer application in the P. densiflora and Q. variabilis stands (P. densiflora: 2.180 μmol m-2 s-1; Q. variabilis: 1.977 μmol m-2 s-1) as compared with the rates measured during the calibration period (P. densiflora: 1.620 μmol m-2 s-1; Q. variabilis: 1.557 μmol m-2 s-1). The mean annual soil CO2 efflux rates in the unfertilized treatments of both stands were not significantly different between the two-year study periods. The Q10 values of fertilized treatments in Q. variabilis stands were higher in the fertilization period (3.41) than in the calibration period (3.14), whereas the Q10 values in P. densiflora stands did not change between the fertilization and calibration periods. The Q10 values of unfertilized treatments in the Q. variabilis stands were lower during the 2016-2017 period (3.69), than in the 2015-2016 period (3.85), whereas the Q10 values in P. densiflora stands were higher during the 2016-2017 period (3.65), than in the 2015-2016 period (3.15). These results indicate that the increase in soil CO2 efflux rates in P. densiflora stands could be more sensitive to fertilization compared with the rates in Q. variabilis stands.