• Title/Summary/Keyword: Calibration Test

Search Result 1,065, Processing Time 0.032 seconds

관성센서 출력 측정을 위한 AF 변환기 교정기법

  • Kim, Jeong-Yong;Cho, Hyun-Chul;Roh, Woong-Rae;Choi, Hyung-Don;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.117-125
    • /
    • 2005
  • Generally, the inertial navigation and guidance unit uses AF(Analog-to-Frequency) converters which convert analog signals into frequency signals to enhance a measurement accuracy of gyroscope and accelerometer outputs. The confidence level of AF converter is guaranteed by a prudential decision of calibration procedure and a performance of periodic calibration test. In this paper, we focus on the synchronous charge balance type AF converter which has a separate positive or negative current input and its calibration method is described. The calibration tests are classified into the scale factor error calibration and the bias calibration. These tests are automatically performed by the calibration program.

  • PDF

A New Online Calibration Algorithm for Array Antenna using Independent Component Analysis

  • Suk, Mi-Kyung;Lee, Jong-Hyun;Chun, Joo-Hwan;Park, Jin-Kyu;Kim, Yong-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1568-1572
    • /
    • 2004
  • This paper proposes a new online calibration algorithm for the array antenna system. As you know, the several previous calibration methods for the mutual coupling did not estimate but measure mutual coupling effect at the real or test-bed system directly. Therefore we suggest some idea to compensate the calibration errors due to mutual coupling effect and mismatch in cables and electronic modules without the off-line calibration. In this work, we can calibrate the array antenna system under the operation of the system using Independent Component Analysis(ICA). This is what is called an online calibration. As you know, the ICA method has permutation and scaling problems. However, we solve problems of the ICA method and apply it to the calibration of an array antenna. The method simultaneously estimates the DOA(Direction of Arrival) of the signals, and calibrates the array for that specific angle. The proposed algorithm is evaluated by computer simulation and its behavior is illustrated by a numerical example.

  • PDF

Determination of Nitrogen Content in Rice Tissue Using Near Infrared Spectroscopy

  • Song, Young-Ju;Cho, Seung-Hyun;Nam-Ki, O.H.;Park, Yeong-Geun
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1262-1262
    • /
    • 2001
  • The rice plant is one of the important staple crops in Korea. The high yield with low cost in rice is required the soil fertility and the development of new precise method of fertilizer application by nutritional diagnosis. Now, in Korea, the nitrogen application system for the rice plant is composed of the basal fertilization, fertilization at tillering stage and fertilization at panicle stage, which the nitrogen fertilization at panicle stage amount to about 30 percent in the total amount. Thus, this experiment carried out to the development of the system that can measure the nitrogen content in the rice plant at panicle stage rapidly with the near infrared spectroscopy, and to predict the appropriate quantity of the nitrogen fertilization at panicle stage based on calibration model for test of nitrogen content in rice plant. The samples were collected from 48 varieties in 4 regions which are mainly cultivated in the southern part of Korea. And then, it collected by classifying into the leaf, the whole plant and the stem since 7 days before the nitrogen fertilization at panicle stage. The ranges of the nitrogen contents were 1.6∼4.0%, 1.7∼3.0% and 1.4∼2.7% in the leaf, the whole plant and the stem, respectively. In the calibration models created by each part of the plant under the Multiple Linear Regression(MLR) method, the calibration model for the leaf recorded the relatively high accuracy. The mutual crossing test on unknown samples were carried out using Partial Least Square(PLS) calibration model. That is, the nitrogen content in the stem was tested by calibration model made by the leaf model and that of stem was tested by calibration model made by whole plant sample. When unknown leaf sample was tested by calibration model made by all sample that collected from each part in rice plant such as leaf, stem and whole plant, it recorded the highest accuracy. As a result, to test the nitrogen content in the rice plant at panicle stage, the nitrogen content in the leaf shall be tested by the calibration model composed of the leaf, the stem and the whole plant. In future, to estimated the amount of nitrogen fertilization at panicle stage for rice plant , it will be calculated based on regression model between rice yield and nitrogen content of leaf measured by calibration model made by mixed sample including leaf, stem and whole plant.

  • PDF

Study on the validation methods of calibration considering correlations (상관관계를 반영한 신용등급 계량화 검정기법 연구)

  • Kim, Enn-Na;Ha, Jeong-Cheol
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.3
    • /
    • pp.407-417
    • /
    • 2010
  • In Basel II compliance, internal rating systems are allowed for banks to enhance the self control and the validation of the system are getting more important. The validation methods are composed of qualitative test and quantitative test, three basic standards of which are discriminatory power, stability and calibration. The aim of this article is to review the quantitative tests for calibration and find a new method for it. These methods for discrimination between forecasted PD and observed PD include binomial test, chi square test, Brier score, traffic lights approach, normal test and extended traffic lights approach. We introduce a modified extended traffic lights approach considering asset correlations.

Calibration for the solar channel of COMS/MI using MODIS-derived BRDF parameters over desert targets

  • Sohn Byung-Ju;Chun Hyoung-wook
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.101-103
    • /
    • 2005
  • Vicarious calibration method using MODIS-derived surface reflectivity data as inputs to a radiative transfer model have been developed for the planned COMS solar channel. Pilot test was conduced over the Simpson Desert targets in Australia. Results suggested that calibration can be achieved within $5\%$ error range.

  • PDF

Level Calibration of Ultrasonic Nondestructive Testing Considering Flaw Position (불연속부의 위치를 고려한 초음파비파괴검사 등급보정)

  • Shin, Byoung-Chul;Song, Ho-San;Jeong, Hwa-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.155-160
    • /
    • 2001
  • KS-code(KS B 0896) for nondestructive ultrasonic testing classifies the quality level by relative flaw size only. But flaw position is more important than the flaw size. Test blocks having artificial holes near surface show lower yield load than the blocks having deeply located holes from the surface. So, level calibration table was proposed for classifying the quality level of welded steel structures.

  • PDF

A calibration of high current measuring sensors by comparison tests (비교 시험에 따른 대전류 측정 센서 교정 결과 분석)

  • Han, Jong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.312-313
    • /
    • 2015
  • For the traceability of high current measuring sensors of high power testing department II(HPTD II) in Korea Electrotechnology Research Institute(KERI), additional comparison tests with reference test object were performed repeatedly. The first intercomparison has been carried out between the reference shunt for Asia and high current shunt of HPTD II in 2013. This paper compares the test results of the calibration in 2014 with them in 2015. The assigned new scale factor of high current sensors will be applied to high power tests in HPTD II until the next high current intercomparison.

  • PDF

An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas (헬륨을 이용한 열유속센서 검정방법의 실험적 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF

ABSOLUTE RADIOMETRIC CALIBRATION OF 1M SATELLITE IMAGERY

  • Lee Sun-Gu;Lee Dong-han;Seo Doo-chun;Song Jeong Heon;Kim Yongseung;Paik Hongyul
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.616-619
    • /
    • 2005
  • CALNAL team of Korea Aerospace Research Institute(KARI) performed field campaigns for absolute radiometric calibration of 1m satellite image on Daejeon and the cal/val site of Goheung. The satellite image have spatial resolution of 1m in panchromatic spectral band of 450-900nm. The performed cal/val method is the reflectance-based of vicarious calibration methods. We collected ground-based and meteology data such as temperature, surface pressure and reflectance of targets, and radiosonde data used only to test in Goheung. Data collected on each field served as input to radiative transfer codes to generate a top-of-atmosphere(TOA) radiance estimate. Derived TOA is compared with DN of overpass satellite to calculate calibration coefficient of gain and offset.

  • PDF

An online Calibration Algorithm using binary spreading code for the CDMA-based Adaptive Antenna Array

  • Lee, Chong-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.32-39
    • /
    • 2006
  • In this paper, an iterative subspace-based calibration algorithm for a CDMA-based antenna array in the presence of unknown gain and phase error is presented. The algorithm does not depend on the array geometry and does not require a prior knowledge of the Directions Of Arrival (DOA) of the signals. The method requires the code sequence of a reference user only. The proposed algorithm is based on the subspace method and root finding approach, and it provides estimates of the calibration vector, the DOA and the channel impulse response, by using the code sequence of a reference user. The performance of the proposed algorithm was investigated by means of computer simulations and was verified using field data measured through a custom-built W-CDMA test-bed. The data show that experimental results match well with the theoretical calibration algorithm. Also, teh study propose an efficient algorithm using the simulated annealing technique. This algorithm overcomes the requirement of initial guessing in the subspace-based approach.