• 제목/요약/키워드: Calibration Procedure

검색결과 401건 처리시간 0.032초

비행시험을 통한 경비행기의 속도계 보정 (Airspeed Calibration of a Light Airplane via Flight Test)

  • 이정훈;류시융;이장호
    • 제어로봇시스템학회논문지
    • /
    • 제14권7호
    • /
    • pp.629-634
    • /
    • 2008
  • This paper presents the flight test procedure and the results for the airspeed indicator calibration of a light airplane the name of ChangGong-91, which is the first type certified aircraft from Korean Ministry of Construction and Transportation, as a part of the flight test validation to get the certification. The flight tests for airspeed position error calibrations are conducted using tower fly by method in order to calibrate swivel head testboom which is attached to the right wing tip of the airplane. Also system to system method is applied in order to calibrate the airspeed indicator of the cockpit. The flight test is conducted at the basis of the 'Korean Airworthiness Standard' which is the regulation of Korean Ministry of Construction and Transportation. The airspeed error range for the testboom and the airspeed indicator are determined to $-0.75{\sim}+0.75$ knot and to $-4.0{\sim}+2.0$ knots, respectively. The calibration results are applied to ChangGong-91 Flight Operation Manual.

지형공간정보체계에서 수치영상자료 취득의 정확도 향상을 위한 주사기의 검정 방법 (Scanner Calibration Method for Higher Accuracy at Acquisition of Digital Imagery Data in GSIS)

  • 최철순
    • 대한공간정보학회지
    • /
    • 제1권2호
    • /
    • pp.153-158
    • /
    • 1993
  • 주사기(scanner)에 의해 수치영상자료를 취득하는 과정에 있어서 기존 사진이나 도면의 좌표체계는 수치영상의 좌표체계로서 변환되므로 이들 좌표체계 간의 변환관계를 설정하는 것은 매우 중요한 일이다. 또한 주사기의 주사운동에 따라 왜곡이 발생할 수 있으므로 이를 보정하기 위한 연구도 이루어져야 한다. 본 연구에서는 항공사진을 주사기에 의해 수치화하는 과정에서의 좌표계의 변환관계를 설정하고 주사기의 왜곡을 검정하기 위한 최적검정모형식을 결정하는 과정을 수행하였다. 그 결과 본 연구에 이용된 주사기에 대한 최적검정모형식이 결정되었다. 또한, 본 연구의 수행과정은 기하학적인 해석을 통하여 검정을 수행하였으므로 타 기종의 주사기를 검정하는 데 있어서도 적용이 가능하다.

  • PDF

사례분석을 통한 ITS 장비 검·교정체계의 구축방안 연구 (Developing an ITS Device's Inspection·Calibration System Based on the Study of Similar Cases)

  • 백남철;이상협;오승훈
    • 대한토목학회논문집
    • /
    • 제26권1D호
    • /
    • pp.17-21
    • /
    • 2006
  • ITS 장비의 체계적인 성능평가는 그 장비의 성능을 일정 수준 이상으로 유지하여 수집 가공 제공 정보의 신뢰성을 확보하기 위한 단계로 매우 중요한 위치를 차지하고 있다. 우리나라에서는 2001년의 "교통체계효율화법"에 ITS 장비의 성능평가와 관련하여 법적 근거가 마련되어 있음에도 불구하고 ITS 장비에 대한 검 교정이 체계적으로 이루어지지 않고 있다. 본 연구에서는 체계적이고 효율적인 ITS 장비의 검 교정체계 구축을 위한 기반을 마련하고자 한다. 이를 위해 국내외의 유사 사례와 ITS 이외 분야의 모범사례를 분석하여 검 교정체계 현황 및 절차 등을 개관하고 정책적인 시사점을 분석하여 제시한다.

노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법 (A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image)

  • 고국원;김민영
    • 한국산학기술학회논문지
    • /
    • 제10권5호
    • /
    • pp.909-916
    • /
    • 2009
  • 본 연구는 위상천이 영사식 모아레 측정기의 기준 위상 측정단계에서 기준 위상의 검출 정확도를 높이기 위한 방안으로, 일반적인 N-bucket 방법이 아닌, 줄무늬 패턴 투사 영상의 직접적인 영상처리를 기반으로, 노이즈가 포함된 영상으로부터 기준 위상을 자동으로 검출하고 보정하는 방법을 다룬다. 일반적으로 기준위상을 정확히 구하기 위해서는 상대적으로 노이즈가 원천적으로 적은 고정밀도의 교정 시편과 이에 맞는 세분화된 교정방법이 필요하다. 하지만, 고가의 시편 제작비용 절감과 고정도 교정을 위한 교정시간의 단축을 위해, 상대적으로 일반 정밀도등급의 제작된 시편으로부터 획득된 영상을 이용하여, 효율적인 기준위상 교정 방법을 제안한다. 투사된 평행 라인 띠가 시편에서 반사되어 카메라로 입력되는 영상으로부터, 영상처리 라인마스크를 이용하여 격자 라인들의 중심점을 정밀하게 추출하고, 각 라인들에서 추출된 샘플링점 기반의 최소자승법을 이용하여, 라인 특징치인 기울기와 절편을 추출함으로써 실제 관측되는 격자 라인의 중심선을 획득하였으며, 획득된 중심선들을 이용하여 N-bucket 알고리즘에 적용할 수 있도록 위상을 추출한 후, 기준위상을 자동으로 생성하였다. 본 연구를 통하여 고가의 시편 제작 없이 빠르게 자동으로 기준위상을 추출할 수 있었다.

지상 초분광카메라 영상의 복사보정 (Vicarious Radiometric Calibration of the Ground-based Hyperspectral Camera Image)

  • 신정일;;김선화;강성진;이규성
    • 대한원격탐사학회지
    • /
    • 제24권2호
    • /
    • pp.213-222
    • /
    • 2008
  • 초분광영상의 활용 가능성은 증대하고 있으나, 연구에 필요한 초분광센서의 공급은 비교적 제한되어 있다. 초분광영상으로부터 정보 획득을 위한 처리와 분석은 대부분 영상에서 획득되는 분광반사율에 기반을 두고 있다. 본 연구의 목표는 사전 복사보정 자료가 없는 지상 초분광카메라 영상의 복사보정 과정을 개발하여 영상의 화소값을 분광반사율로 변환하고자 한다. 다양한 분광반사특성을 가진 22개 클래스로 구성된 모의지표물을 대상으로 분광측정기를 이용한 대리 복사보정 절차를 수행하였다 분광측정기로 측정된 복사량과 영상의 화소값의 관계를 이용하여 120개 밴드 초분광영상의 화소값을 센서감지 복사량(radiance)로 변환하는 보정계수를 도출하였다. 영상 촬영 및 분광측정이 대기의 영향이 거의 없는 지상 근접 촬영으로 이루어졌기 때문에, 화소값을 반사율(reflectance)로 직접 변환하는 보정계수도 산출하였다. 그러나 원거리 촬영이나 공중 촬영으로 획득된 영상의 경우 산출된 복사보정 계수는 센서감지 복사량 변환에만 유효하며, 반사율을 얻기 위해서는 추가적인 대기보정 절차가 별도로 수행되어야 한다.

사진측량기법을 이용한 엑스선영상의 3차원 모형화 (Three-dimensional Reconstruction of X-ray Imagery Using Photogrammetric Technique)

  • 김의명
    • 대한토목학회논문집
    • /
    • 제28권2D호
    • /
    • pp.277-285
    • /
    • 2008
  • 엑스선 영상은 의료분야에서 많이 활용되고 있으며 특히 인간의 골격형성 과정에서 발생할 수 있는 척추만곡의 변형을 파악하는 데 아주 효율적이다. 본 연구에서는 엑스선 영상의 사진기 검정과 엑스선 영상을 이용한 대상물의 3차원 좌표 결정에 중점을 두었다. 엑스선 사진기를 이용한 대상물의 좌표결정 과정은 엑스선 사진기 검정을 위해서 방사선이 투과되지 않게 제작된 쇠볼이 배치된 1차 검정대상물을 이용하여 엑스선 영상의 내부표정요소와 외부표정요소를 결정하고 이로 부터 엑스선에 교차하게 아크릴로 제작된 두 면을 가지고 있는 엑스선 검정장의 3차원 좌표를 결정하는 2단계 과정을 거쳤다. 사진측량기법에 의해 결정된 엑스선 검정장의 3차원 좌표값은 정밀하게 관측된 CMM과의 비교를 통하여 그 정확도를 평가하였으며 엑스선의 진행방향(X축)에 대한 오차가 Y축과 Z축에 비해 상대적으로 높게 나타났으나 Y축과 Z축에 대한 위치오차는 수 mm의 정확도를 나타내었다. 본 연구를 통해서 사진측량기법은 환자의 3차원 위치결정이나 의료용 교정기기를 제작하는데 도움을 줄 수 있을 것으로 사료된다.

Employing a fiber-based finite-length plastic hinge model for representing the cyclic and seismic behaviour of hollow steel columns

  • Farahi, Mojtaba;Erfani, Saeed
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.501-516
    • /
    • 2017
  • Numerical simulations are prevalently used to evaluate the seismic behaviour of structures. The accuracy of the simulation results depends directly on the accuracy of the modelling techniques employed to simulate the behaviour of individual structural members. An empirical modelling technique is employed in this paper to simulate the behaviour of column members under cyclic and seismic loading. Despite the common modelling techniques, this technique is capable of simulating two important aspects of the cyclic and seismic behaviour of columns simultaneously. The proposed fiber-based modelling technique captures explicitly the interaction between the bending moment and the axial force in columns, and the cyclic deterioration of the hysteretic behaviour of these members is implicitly taken into account. The fiber-based model is calibrated based on the cyclic behaviour of square hollow steel sections. The behaviour of several column archetypes is investigated under a dual cyclic loading protocol to develop a benchmark database before the calibration procedure. The dual loading protocol used in this study consists of both axial and lateral loading cycles with varying amplitudes. After the calibration procedure, a regression analysis is conducted to derive an equation for predicting a varying calibrated modelling parameter. Finally, several nonlinear time-history analyses are conducted on a 6-story steel special moment frame in order to investigate how the results of numerical simulations can be affected by employing the intended modelling technique for columns instead of other common modelling techniques.

NUMERICAL ANALYSIS PROCEDURE FOR PREDICTING TEMPERATURE FIELD IN DESIGN OF AUTOMOTIVE FRICTION CLUTCH

  • LEE B.;CHO C.
    • International Journal of Automotive Technology
    • /
    • 제7권1호
    • /
    • pp.61-68
    • /
    • 2006
  • In design of the friction clutches of automobiles, knowledge on the thermo-elasticity a priori is very informative in the initial design stage. Especially, the precise prediction technique of maximum temperature and stress should be requested in design of mechanical clutches for their durability and compactness. In this study, an efficient and reliable analysis technique for the design of the mechanical clutches by using computer modeling and numerical method was developed. A commercial software STAR-$CD^{TM}$ was used to find the convective heat-transfer coefficients. MSC/$NASTRAN^{TM}$ software was followed to predict the temperature of clutch with utilization of estimated coefficients. Some experiments were also performed with a dynamometer to verify the procedure and calibrate the thermal load. As a conclusion, a design procedure, including numerical steps and experimental techniques for calibration, was proposed.

Bayesian Hypothesis Testing for the Ratio of Two Quantiles in Exponential Distributions

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제18권3호
    • /
    • pp.833-845
    • /
    • 2007
  • When X and Y have independent exponential distributions, we develop a Bayesian testing procedure for the ratio of two quantiles under reference prior. The noninformative prior such as reference prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. So we develop a Bayesian testing procedure based on fractional Bayes factor and intrinsic Bayes factor. We show that the posterior density under the reference prior is proper and propose the Bayesian testing procedure for the ratio of two quantiles using fractional Bayes factor and intrinsic Bayes factor. Simulation study and a real data example are provided.

  • PDF

STANDARDISATION OF NIR INSTRUMENTS, INFLUENCE OF THE CALIBRATION METHODS AND THE SIZE OF THE CLONING SET

  • Dardenne, Pierre;Cowe, Ian-A.;Berzaghi, Paolo;Flinn, Peter-C.;Lagerholm, Martin;Shenk, John-S.;Westerhaus, Mark-O.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1121-1121
    • /
    • 2001
  • A previous study (Berzaghi et al., 2001) evaluated the performance of 3 calibration methods, modified partial least squares (MPLS), local PLS (LOCAL) and artificial neural networks (ANN) on the prediction of the chemical composition of forages, using a large NIR database. The study used forage samples (n=25,977) from Australia, Europe (Belgium, Germany, Italy and Sweden) and North America (Canada and U.S.A) with reference values for moisture, crude protein and neutral detergent fibre content. The spectra of the samples were collected using 10 different Foss NIR Systems instruments, only some of which had been standardized to one master instrument. The aim of the present study was to evaluate the behaviour of these different calibration methods when predicting the same samples measured on different instruments. Twenty-two sealed samples of different kind of forages were measured in duplicate on seven instruments (one master and six slaves). Three sets of near infrared spectra (1100 to 2500nm) were created. The first set consisted of the spectra in their original form (unstandardized); the second set was created using a single sample standardization (Clone1); the third was created using a multiple sample procedure (Clone6). WinISI software (Infrasoft International Inc., Port Mathilda, PA, USA) was used to perform both types of standardization, Clone1 is just a photometric offset between a “master” instrument and the “slave” instrument. Clone6 modifies both the X-axis through a wavelength adjustment and the Y-axis through a simple regression wavelength by wavelength. The Clone1 procedure used one sample spectrally close to the centre of the population. The six samples used in Clone 6 were selected to cover the range of spectral variation in the sample set. The remaining fifteen samples were used to evaluate the performances of the different models. The predicted values for dry matter, protein and neutral detergent fibre from the master Instrument were considered as “reference Y values” when computing the statistics RMSEP, SEPC, R, Bias, Slope, mean GH (global Mahalanobis distance) and mean NH (neighbourhood Mahalanobis distance) for the 6 slave instruments. From the results we conclude that i) all the calibration techniques gave satisfactory results after standardization. Without standardization the predicted data from the slaves would have required slope and bias correction to produce acceptable statistics. ii) Standardization reduced the errors for all calibration methods and parameters tested, reducing not only systematic biases but also random errors. iii) Standardization removed slope effects that were significantly different from 1.0 in most of the cases. iv) Clone1 and Clone6 gave similar results except for NDF where Clone6 gave better RMSEP values than Clone1. v) GH and NH were reduced by half even with very large data sets including unstandardized spectra.

  • PDF