• Title/Summary/Keyword: Calibration Interval

Search Result 97, Processing Time 0.025 seconds

ASTROMETRIC OBSERVATION OF MIRA VARIABLES WITH VERA

  • NAKAGAWA, AKIHARU;OMODAKA, TOSHIHIRO;HANDA, TOSHIHIRO;KAMEZAKI, TATSUYA;PROJECT, VERA
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.189-191
    • /
    • 2015
  • The calibration of the period luminosity relation (PLR) for Galactic Mira variables is one of the principle aims of the VERA project. We observe $H_2O$ maser emission at 22 GHz associated with Mira variables in order to determine their distances based on annual parallaxes. We conduct multi-epoch VLBI observations over 1-2 years with a typical interval of one month using VERA in order to obtain annual parallaxes with an accuracy of better than than 10%. Recently, the annnual parallax of T Lep was determined to be $3.06{\pm}0.04$ mas corresponding to a distance of $327{\pm}4pc$ (Nakagawa et al., 2014). The circumstellar distribution and kinematics of $H_2O$ masers was also revealed. With accurate distances to the sources, calibrations of K-band absolute magnitudes ($M_K$) can be improved compared to conventional studies. By compiling Mira variables whose distances were determined with astrometric VLBI, we obtained a PLR of $M_K=3.51logP+1.37{\pm}0.07$.

Preliminary Study for Image-Based Measurement Model in a Construction Site (이미지 기반 건설현장 수치 측정 모델 기초연구)

  • Yoon, Sebeen;Kang, Mingyun;Kim, Chang-Won;Lim, Hyunsu;Yoo, Wi Sung;Kim, Taehoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.287-288
    • /
    • 2023
  • The inspection work at construction sites is one of the important supervisory tasks, which involves verifying that the building is being constructed by the numerical values specified in the design drawings. The conventional measuring method for inspection involves using tools or equipment such as rulers directly by the personnel at the site, and it is usually confirmed by vision. Therefore, this study proposes an model to measure numerical values on images of the construction site. Through the case study to measure the installation interval of jack supports, the proposed algorithm was verified the effiect and validity. The results of this study suggest that it can support inspection work even in the office, which may have been overlooked by on-site inspectors, and contribute to the digitization of inspection work at construction sites.

  • PDF

A Study on Quality Improvement by Evaluation and Application of GUM-based Measurement Uncertainty (GUM 기반 측정불확도의 평가 및 적용에 의한 품질개선)

  • Insoo Choi;Sun Hur
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.3
    • /
    • pp.419-434
    • /
    • 2023
  • Purpose: Measurement results obtained under non-ideal measurement environment conditions may contain uncertain factors. As a result, the reliability of measurement results may be deteriorated. In this study, we tried to find ways to improve quality by evaluating and applying measurement uncertainty based on GUM. Methods: In the flatness measurement of semiconductor parts, uncertainty factors that could occur under actual environmental conditions of workers were derived, and measurement uncertainties were calculated, and methods for minimizing the main factors affecting the measurement results were analyzed. Results: Depending on the part and the coordinate measuring machine, it was shown that the effect of dispersion caused by repeated measurements as type A uncertainty and the effect of the calibration results of equipment as type B uncertainty have the main influence. Conclusion: Depending on the uncertainty factors of type A and type B and the influence of the total expanded uncertainty, the central value and confidence interval of the initial measurement results showed fluctuations. It is considered that analysis and measures for the main uncertainty factors are needed as quality improvement in the industrial field.

The Effects of Improvement in Clay with High Moisture Contents Using the Filter Type Vacuum Consolidation Method (필터형 진공압밀공법을 이용한 고함수비 점토지반의 개량효과)

  • Oh, Sewook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.9
    • /
    • pp.55-60
    • /
    • 2010
  • This study are carried out to an lab model tests to develop a construction method that solidifies high-water content cohesive soil by using filter type drain and vacuum pressure, and that stabilizes the ground by accelerating horizontal drain at incline or in tunnel. The calibration chamber was designed within length of 1.5m and height of 50cm, and a drainage hole for preconsolidation, a switchgear and a piezometer were installed at the bottom part of the chamber. Also, a settlement gage was installed at the top part so that it can measure the settlement by time. The calibration ground basis was made in a form of thin layer from kaolinite and bentonite in 9:1 ratio stirred at 130% water content condition. A filter type drain was installed at chamber center and a vacuum pressure of 0.8MPa was applied through a hose linked to the cap at the top part, then, the settlement was measured in every 1 hour interval. After experiment, the moisture contents were measured by position, then, verified the increase of solidity of the ground through a triaxial compression test on undisturbed profile. After 11 days from the effective date, it was observed that the settlement decreased by maximum 35mm and the water content ratio was reduced by 38% at most while the solidity of the ground increased by 5~8 times greater than before preconsolidation.

Measurement of Quality Parameters of Honey by Reflectance Spectra

  • Park, Chang-Hyun;Yang, Won-Jun;Sohn, Jae-Hyung;Kim, Jong-Hoon
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1530-1530
    • /
    • 2001
  • The objectives of this study were to develop models to predict quality parameters of Korean bee-honeys by visible and NIR spectroscopic technique. Two kinds of bee-honey fronl acacia and polyflower sources were tested in this study. The honeys were harvested in the spring of 2000 and stored in the storage facility at 20$^{\circ}C$ during experiments. Total of 394 samples of honey were analyzed. Reflectance spectra, moisture contents, ash, invert sugar, sucrose, F/G (fructose/glucose) ratio, HMF (hydroxymethyl furfural), and C12/C13 ratio of honeys were measured. The average values for the tested honeys were 19.9% of moisture contents, 0.12% of ash, 68.4% of invert sugar, 5.7% of sucrose, 1.27 of F/G(fructose/glucose) ratio, 14.4 mg/kg of HMF, and -19.1 of C12/C13 ratio. A spectrophotometer, equipped with a single-beam scanning monochromator (NIR Systems, Model 6500, USA) and a horizontal setup module, was used to collect reflectance data from honey. The reflectance spectra were measured in wavelength ranges of 400∼2,498 nm. with 2 nm of interval. Thirty-two repetitive scans were averaged, transformed to log(1/Reflectance), and then were stored in a microcomputer file, forming one spectrum per measurement. A sample cell and reflectance plate were made to hold honey samples constantly. Spectra of honey samples were divided into a calibration set and a validation set. The calibration set was used during model development, and the validation set was used to predict quality parameters from unknown spectra. The PLS(Partial Least Square) models were developed to predict the quality parameters of honeys. The first and the second derivatives of raw spectra were also used to develop the models with proper smoothing gap. The MSC (multiplicative scatter correction) and the SNV & Dtr.(standard normal variate and detranding) preprocessing were applied to all spectra to minimize sample-to-sample light scatter differences. The PLS models showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1100∼2200 nm. However, the PLS analysis was not good enough to predict HMF of honeys.

  • PDF

Determination of Barley Grain Components at Different Maturing Stages by Near Infrared Reflectance Spectroscopic Analysis (근적외선분광분석법에 의한 등숙시기별 보리종실의 성분측정)

  • Kim, Byung-Joo;Park, Eui-Ho;Suh, Hyung-Soo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.1
    • /
    • pp.13-19
    • /
    • 1996
  • This study was conducted to establish the rapid determination method for major components of maturing covered barley grains, and to improve the efficiency of selection in barley breeding. Near Infrared Reflectance Spectroscopy (NIRS) is an established, economical and nondestructive technique applied widely to the food and feed industry. 34 barley lines were sampled at 5 day-interval from 25 to 35 days after heading. A standard regression analysis for the data obtained by analytical laboratory methods and NIRS method was carried out to get a useful calibration equation. The simple significant correlation between these two methods at 25 days after heading was recognized in starch and $\beta$-glucan contents. At 30 days after heading the data obtained by two methods showed significant correlation in starch, $\beta$-glucan and protein contents. Analyzed data and that from NIRS method at 35 days after heading was significantly correlated in starch and protein contents. It was concluded that the applicability of NIRS method for the components analysis in maturing barley grains was different depending on maturing stages and components.

  • PDF

Persistence Study of Thiamethoxam and Its Metabolite in Kiwifruit for Establishment of Import Tolerance

  • Il Kyu Cho;Gyeong Hwan Lee;Woo Young Cho;Yun-Su Jeong;Danbi Kim;Kil Yong Kim;Gi-Woo Hyoung;Chul Hong Kim
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.4
    • /
    • pp.355-364
    • /
    • 2022
  • BACKGROUND: Pre-harvest interval and decline pattern of thiamethoxam were determined in kiwifruit using liquid chromatography-tandem mass spectrometry (LCMS/MS). The study was carried out to propose import tolerance using OECD maximum residue limit (MRL) calculator for the export promotion of kiwifruit to Taiwan. METHODS AND RESULTS: The thiamethoxam residue in kiwifruit was determined by using the LC-TriQ-MS/MS with the analytical process to set up the import tolerance under greenhouse conditions for Taiwan. Excellent linearity was observed for all of the analytes with a determination coefficient (R2)≥0.99. The limit of quantification was determined to be 0.01 mg/kg for both thiamethoxam and clothianidin in kiwifruit. Linearity was determined from the co-efficient of determinants (R2) obtained from the seven-point calibration curve. The standard calibration curve showed as follows; 1) Site 1 (Gimje): y = 944,406X + 1,583 (R2=0.9995), 2) Site 2 (Goheung): y = 1,356,205X + 934 (R2=0.9983), and 3) Site 3 (Jangheung): y = 1,239,937X - 3,090 (R2=0.9908). The residue of thiamethoxam in the kiwifruit for three decline trials showed the range of 0.35 to 0.56 mg/kg in site 1 (Gimje), 0.24 to 0.55 mg/kg in site 2 (Goheung), and 0.28 to 0.42 mg/kg in site 3 (Jangheung), respectively. However, clothianidin was not detected in all of the treatments. The maximum residual amounts (decline) in the samples, sprayed according to the safe-use standard for thiamethoxam 10% WG in kiwifruit (30 days before harvest, 3 sprays every 7 days) were 0.56 mg/kg in site 1, 0.55 mg/kg in site 2, and 0.42 mg/kg in site 3, respectively. CONCLUSION(S): The import tolerance (IT) of thiamethoxam for kiwifruit may be proposed to be 0.9 mg/kg by using the OECD MRL calculator.

Comparison of ISO-GUM and Monte Carlo Method for Evaluation of Measurement Uncertainty (몬테카를로 방법과 ISO-GUM 방법의 불확도 평가 결과 비교)

  • Ha, Young-Cheol;Her, Jae-Young;Lee, Seung-Jun;Lee, Kang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.647-656
    • /
    • 2014
  • To supplement the ISO-GUM method for the evaluation of measurement uncertainty, a simulation program using the Monte Carlo method (MCM) was developed, and the MCM and GUM methods were compared. The results are as follows: (1) Even under a non-normal probability distribution of the measurand, MCM provides an accurate coverage interval; (2) Even if a probability distribution that emerged from combining a few non-normal distributions looks as normal, there are cases in which the actual distribution is not normal and the non-normality can be determined by the probability distribution of the combined variance; and (3) If type-A standard uncertainties are involved in the evaluation of measurement uncertainty, GUM generally offers an under-valued coverage interval. However, this problem can be solved by the Bayesian evaluation of type-A standard uncertainty. In this case, the effective degree of freedom for the combined variance is not required in the evaluation of expanded uncertainty, and the appropriate coverage factor for 95% level of confidence was determined to be 1.96.

Study on Enhancement of TRANSGUIDE Outlier Filter Method under Unstable Traffic Flow for Reliable Travel Time Estimation -Focus on Dedicated Short Range Communications Probes- (불안정한 교통류상태에서 TRANSGUIDE 이상치 제거 기법 개선을 통한 교통 통행시간 예측 향상 연구 -DSRC 수집정보를 중심으로-)

  • Khedher, Moataz Bellah Ben;Yun, Duk Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.249-257
    • /
    • 2017
  • Filtering the data for travel time records obtained from DSRC probes is essential for a better estimation of the link travel time. This study addresses the major deficiency in the performance of TRANSGUIDE in removing anomalous data. This algorithm is unable to handle unstable traffic flow conditions for certain time intervals, where fluctuations are observed. In this regard, this study proposes an algorithm that is capable of overcoming the weaknesses of TRANSGUIDE. If TRANSGUIDE fails to validate sufficient number of observations inside one time interval, another process specifies a new validity range based on the median absolute deviation (MAD), a common statistical approach. The proposed algorithm suggests the parameters, ${\alpha}$ and ${\beta}$, to consider the maximum allowed outlier within a one-time interval to respond to certain traffic flow conditions. The parameter estimation relies on historical data because it needs to be updated frequently. To test the proposed algorithm, the DSRC probe travel time data were collected from a multilane highway road section. Calibration of the model was performed by statistical data analysis through using cumulative relative frequency. The qualitative evaluation shows satisfactory performance. The proposed model overcomes the deficiency associated with the rapid change in travel time.

Bioequivalence of Atorva Tablet® to Lipitor Tablet® (Atorvastatin 20 mg) (리피토정® (아토르바스타틴 20 mg)에 대한 아토르바정®의 생물학적동등성)

  • Lim, Hyun-Kyun;Lee, Tae-Ho;Lee, Jae-Hyun;Youm, Jeong-Rok;Song, Jin-Ho;Han, Sang-Beom
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • The present study describes the evaluation of the bioequivalence of two atorvastatin tablets, Lipitor $Tablet^{(R)}$ (Pfizer, reference drug) and Atorva $Tablet^{(R)}$ (Yuhan, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Forty-nine healthy male Korean volunteers received each medicine at the atorvastatin dose of 40 mg in a $2{\times}2$ crossover study with a two weeks washout interval. After drug administration, serial blood samples were collected at a specific time interval from 0-48 hours. The plasma atorvastatin concentrations were monitored by an high performance liquid chromatography -tandem mass spectrometer (LC-MS/MS) employing electrospray ionization technique and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.5 min and calibration curves were linear over the concentration range of 0.1-100 ng/mL for atorvastatin. The method was validated for selectivity, sensitivity, linearity, accuracy and precision. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48hr) was calculated by the linear log trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were complied trom the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Atorva $Tablet^{(R)}$ / Lipitor $Tablet^{(R)}$ were ${\log}\;0.9413{\sim}{\log}\;1.0179$ and ${\log}\;0.831{\sim}{\log}\;1.0569$, respectively. These values were within the acceptable bioequivalence intervals of ${\log}\;0.8{\sim}{\log}\;1.25$. Based on these statistical considerations, it was concluded that the test drug, Atorva $Tablet^{(R)}$ was bioequivalent to the reference drug, Lipitor $Tablet^{(R)}$.