• Title/Summary/Keyword: Calculated AC/A

Search Result 267, Processing Time 0.026 seconds

Economic Analysis by Cost Estimation and Externality Classification to Agricultural Water Supply (논 농업용수의 외부효과 구분과 비용산정에 따른 경제성 분석)

  • Kim, Hae-Do;Hur, Seung-Oh;Jo, Jin-Hun;Na, Min-Chul
    • KCID journal
    • /
    • v.17 no.2
    • /
    • pp.3-16
    • /
    • 2010
  • The subject of externality of agricultural water supply has been discussed in the OECD AC ( Organization for Economic Cooperation and Development Agriculture Committee) while argued between monsoon Asian developing countries and the agricultural product export nations (Australia, EU, etc). It argued that a 'positive' approach to multifunctionality views agriculture as an economic activity with multiple, interconnected outputs or effects, and a 'normative' approach interprets multifunctionality in terms of the multiple roles assigned to agriculture. and the agricultural product export nations insisted 'negative' approach to externality of agricultural water supply like causing water pollution. So, in this study, define the externalities (positive, negative and economic, environmental) in terms of the agricultural water supply and calculate benefit and cost each the externalities by cost estimation. As results, BC is calculated to 1.28 which means that it is more economical to agricultural water supply and shows that although the negative exernalities comes out while supply the agricultural water, it still more valuable to supply the agricultural water.

  • PDF

A Study on the Experimental Relation between Parameters for Determining Dry Film Thickness in the Application of Anti Corrosive Paint using Hydraulic Plural Component (이액형 도장기기를 이용한 방식 도장 시 건도막두께 결정인자들에 대한 실험적 상관관계 연구)

  • Yun, Won-Jun;Choi, Min-Gu;Lee, Sung-Goun;Lee, Yun-Sig;Heo, Byung-Dong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.5
    • /
    • pp.433-439
    • /
    • 2012
  • Anticorrosive paint is the most widely used in shipbuilding and the dry film thickness is very important in terms of productivity and assurance of anticorrosive performance. However, it is difficult to achieve the recommended target film thickness because the dry film thickness depends on labor's skill in practice and is affected by a number of parameters, such as spray pressure, paint flow rate, tip size, spray distance, SVR(Solid Volume Ratio), etc. Present paper derives an empirical equation through the correlation analysis of parameters selected by spray experiments of anti corrosive painting in order to predict the coated status. Comparing the calculated results with practical data, we show that the empirical equation can successfully expect DFT(Dry Film Thickness).

The caloric expenditure of 1,000 Kcal per week can be a meaningful intervention for controlling coronary artery disease risk factors in older female adults

  • Joo, Kee-Chan
    • Korean Journal of Health Education and Promotion
    • /
    • v.32 no.5
    • /
    • pp.73-81
    • /
    • 2015
  • Objectives: We tried to confirm physical activity of 1,000 Kcal per week was a meaningful point in controlling coronary artery disease risks in female older adults. Methods: Participants were 66 female older adults recruited from senior welfare center. Participants were provided with accelerometer (e-step, Kenz, Japan) for measuring daily energy expenditure. Graded exercise test was done for measuring aerobic fitness. Blood glucose and lipid were analyzed. Framingham risk score was calculated based on blood glucose, blood lipid, and smoking. These variables were compared between the group expended more than 1,000 Kcal/week and the group with energy expenditure below 1,000 Kcal/week. Results: The group expended over 1,000kcal/week showed to be superior to the counterpart group in following variables; AC(Abdominal Circumference), %BF, $HR_{rest}$(resting heart rate), $VO_{2peak}$, FBG, LDL-C, TG, BDI-II, QOL, AR(Absolute Risk), RR(Relative Risk). Conclusions: The group expended over 1,000 Kcal/week was likely to have less probability in CAD than group expended less than 1,000 Kcal/week. The result of this study suggests the important role of active daily life that can be replaced with that of regular exercise especially for those who are not available to do structured exercise.

Analysis on DC Glow Discharge Properties of Ar Gas at the Atmosphere Pressure (대기압 Ar 가스의 직류 글로우 방전 특성분석)

  • So, Soon-Youl
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.417-422
    • /
    • 2010
  • Atmosphere Plasma of Gas Discharge (APGD) has been used in plasma sources for material processing such as etching, deposition, surface modification and so on due to having no thermal damages. The APGD researches on AC source with high frequency have been mainly processed. However, DC APGD studies have been not. In order to understand APGD further, it is necessary to study on fundamental properties of DC APGD. In this paper, we developed a one-dimensional fluid simulation model with capacitively coupled plasma chamber at the atmosphere pressure (760 [Torr]). Nine kinds of Ar discharge particles such as electron (e), positive ions ($Ar^+$, $Ar_2^+$) and neutral particles ($Ar_m^*$, $Ar_r^*$, $Ar_h^*$, $Ar_2^*$(1), $Ar_2^*$(3) and Ar gas) are considered in the computation. The simulation was worked at the current range of 1~15 [mA]. The characteristics of voltage-current were calculated and the structure of Joule heating were discussed. The spatial distributions of Ar DC APGD and the mechanism of power consumption were also investigated.

A Watermarking Method Based on the Trellis Code with Multi-layer (다층구조를 갖는 trellis부호를 이용한 워터마킹)

  • Lee, Jeong Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.949-952
    • /
    • 2009
  • In this paper, a watermarking method based on the trellis code with multi-layer is proposed. An image is divided $8{\times}8$ block with no overlapping, and compute the discrete cosine transform(DCT) of each block, and the 12 medium-frequency AC terms from each block are extracted. Next it is compared with gaussian random vectors with zero mean and unit variance. As these processing, the embedding vectors with minimum linear correlation can be obtained by Viterbi algorithm at each layer of trellis coding. To evaluate the performance of proposed method, the average bit error rate of watermark message is calculated from different several images.

  • PDF

Numerical Analysis of Transport Current Losses in Stacked HTS Conductors (적층 형태의 고온 초전도선재에서의 통전손실 수치 해석)

  • 최세용;나완수;김정호;주진호;류경우
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • We have studied alternating transport current losses in the vertically stacked high temperature superconducting tapes(HTS) using numerical techniques. In the case of stacked conductors, HTS tapes are exposed to self-field generated by transport current itself and also experienced external magnetic field around adjacent tapes. It is well known that magnetic interactions between neighbored tapes have significant effect on their properties of superconducting tapes such as current distribution, AC loss, and critical current. In this paper, we investigated the transport current losses in stacked conductors consisting of a few of the HTS tapes using numerical analysis. Current distributions are calculated in HTS tape cross-section taking account of magnetic field dependencies, which are represented superconducting nonlinear properties. Dissipated losses in tape and stacked conductors were integrated with current distribution and electric field intensity in the whole conductor region. Finally estimated results were discussed and verified through the analytical theory.

  • PDF

The Analysis of Short Current on Actual System through Power Analysis of AT Feeder System for Electric Railway (전기철도 AT급전계통 전력해석을 통한 실계통의 단락전류 분석)

  • Jung, No-Geon;Jung, Ho-Sung;Koo, Kyung-Wan;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1582-1587
    • /
    • 2014
  • In this paper, we perform a modeling for the AT Feeder system in AC electric railway and we utilize the power EMTDC program to implement about AT feeder system modeling. In addition, we study the impedance characteristics of the AT feeder system and calculated fault current and impedance according to the distance due to fault accident. Based on it's result, fault current are compared between calculating the value and simulation value in EMTDC modeling. Impedance of power system is Largest at the middle point of the system and is smallest near autotransformer, and then showed that the fault current is inversely proportional to impedance characteristics.

Research for Measurement and Modeling on Blocked Force of Electroactive Paper (생체 모방 종이 작동기 힘의 측정 및 모델링에 관한 연구)

  • Kang, Yu-Keun;Kim, Jae-Hwan;Jung, Woo-Chul;Song, Chun-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.731-734
    • /
    • 2005
  • Generally, characteristics of electromechanical actuators are coupled with the mechanical and the electrical properties. Important mechanical parameters of these actuators are the achievable force and displacement in the presence of electric field. These mechanical parameters are related to the stress and strain of the materials and the actuator geometry. This paper presents how to measure the blocked force by using the micro-balance. The blocked force is defined as the force produced by the transducer under an applied voltage when the tip is constrained to zero motion. Also, a theoretical force by using the cantilever beam model is calculated under elastic domain. From the sample of 4 cm $\times$ 1 cm $\times$ 20 $\mu$m, the blocked farce measured from the equipment is 20.3 $\mu$N at 8 V$_{DC}$. By comparing it with the theoretical value, 24.9 $\mu$N, the blocked force measurement is acceptable. The furce measurement is also investigated with different AC electric fields and the frequency.

  • PDF

Air Density Measurement in a Narrow Test Section Using a Laser Absorption Spectroscopy (레이저 흡수 분광법을 사용한 좁은 시험 구간 내 공기 밀도 측정)

  • Shim, Hanseul;Jung, Sion;Kim, Gyeongrok;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.11
    • /
    • pp.893-900
    • /
    • 2021
  • In this study, air density in a narrow test section is measured using a laser absorption spectroscopy system that detects oxygen absorption lines. An absorption line pair at 13156.28 and 13156.62 cm-1 are detected. A gas chamber with a height of 40 mm is used as a narrow test section. A triangular spiral-shaped laser path is applied in the gas chamber to amplify absorption strength by extending laser beam path length. A well-known logarithm amplifier and a secondary amplifier are used to electrically amplify absorption signal. An AC-coupling is applied after the logarithm amplifier for signal saturation prevention and noise suppression. Procedure of calculating spectral absorbance from output signal is introduced considering the logarithm amplifier circuit configuration. Air density is determined by fitting the theoretically calculated spectral absorbance to the measured spectral absorbance. Test conditions with room temperature and a pressure range of 10~100 kPa are made in a gas chamber using a Bourdon pressure gauge. It is confirmed that air density in a narrow test section can be measured within a 16 % error through absorption signal amplification using a triangular spiral-shaped beam path and a logarithm amplifier.

Evaluation of Pheromone Lure of Grapholita molesta (Lpidoptera: Torticidae) and Forecasting Its Phenological Events in Suwon (복숭아순나방 성페로몬 미끼 평가 및 수원지역에서 주요 발생시기 예찰)

  • Kim Dong Soon;Boo Kyung Saeng;Jeon Heung Yong
    • Korean journal of applied entomology
    • /
    • v.43 no.4 s.137
    • /
    • pp.281-289
    • /
    • 2004
  • The sex pheromone blend (28-12AC : E8-12AC : Z8-12OH = 95 : 5 : 1) of oriental fruit moth, Grapholita molesta (Busck), was evaluated with reference to its male attractivity at different dosage and lure longevity of 1.0 mg in a field condition. Also, degree-days (DD) were calculated up to major phenological events of G. molesta using seasonal adult flights monitored by pheromone traps and egg population densities in early season in Suwon peach orchards. In the range of 0.1-4.0 mg dosage examined, G. molesta males caught in pheromone trap decreased with increasing total pheromone doses. The highest number of G. molesta males were attracted in traps baited with 0.1 mg-lure, and there were no significantly differences among 0.5 to 4.0 mg-lure. In longevity test with a 1.0 mg-lure, there was no difference in mean numbers of G. molesta males caught between traps with fresh-baited lures every 20d and field-lasted lures up to ${\approx}50d$ after trap installation, but thereafter more G. molesta males were attracted in the field-lasted lures than in the fresh-baited lures. Accumulated degree-days (DD) from January 1 to the first adult emergence (biofix) were 39DD at a lower threshold temperature $8.1^{\circ}C$. Degree-days from the biofix up to the 1st adult peak through 4th peak were 98DD, 620DD, 1233DD, and 1916DD, respectively. Required degree-days from the 1st adult peak to the 1st egg peak were 130DD, while the 2nd egg peak timing was simultaneous with the 2nd adult peak. Further, management strategies of G. molesta were discussed in peach orchards.