• Title/Summary/Keyword: Cadaver Test

Search Result 23, Processing Time 0.031 seconds

The Mechanical Properties of Trabecular Bone in Knee Joint (무릎관절 해면뼈의 기계적 물성)

  • Kwak, Dai-Soon;Oh, Taek-Yul;Han, Seung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.6
    • /
    • pp.131-135
    • /
    • 2009
  • In this study, we performed the compressive strength test of trabecular bone in knee joint for measuring the elastic modulus and ultimate strength. The main knee joint is femorotibial articulation between the lateral and medial femorotibial condyle. In the case of osteoarthritis, some patients have only medial condylar osteoarthritis. We performed the mechanical test for comparison the difference of the each condylar strength. We used diamond core-drill and linear precision saw for making the specimens. Specimens were cored from both condyle in distal femur and proximal tibia in fresh cadaver (male 10, female 12), and tested by universal test machine with temperature control saline circulation system. Results of the test in distal femoral parts, averaged elastic modulus was $360.61{\pm}159.40MPa$ for male, $150.89{\pm}70.65MPa$ for female. Averaged ultimate strength was $6.79{\pm}2.91MPa$ for male, $2.89{\pm}1.31MPa$ for female. Male was 2.4 times stronger than female. In the proximal tibial parts, averaged elastic modulus was $108.80{\pm}52.88MPa$ for male, $73.45{\pm}55.06MPa$ for female. Averaged ultimate strength was $2.59{\pm}1.39MPa$ for male, $1.75{\pm}1.16MPa$ for female. Male was 1.5 times stronger than female. In the distal femoral condyle, medial condyle had more strength than lateral condyle at middle region. But lateral condyle had more strength than medial condyle at anterior & posterior regions (p<0.02). In the proximal tibial condyle, medial condyle had more strength than lateral condyle. (p<0.01).

Establishment of a Release Test Reflecting in vitro Skin Permeation of Nicotine from Commercial Patches (니코틴 패취제로부터 니코틴의 피부투과를 반영하는 방출시험법의 설정)

  • Lee, Su-Jung;Kim, Jae-Keun;Yun, Mi-Ok;Kim, Ho-Jeong;Shim, Chang-Koo;Ze, Keum-Ryon
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.1
    • /
    • pp.27-32
    • /
    • 2000
  • Various release test methods have been applied for the evaluation of nicotine release in vitro from commercial patches. However, whether and how the release data reflect the permeation of nicotine across the skin, is not fully elucidated. To predict in vivo bioavailability from in vitro release tests, correlation between in vitro release and in vitro skin permeation was assessed in the present study. Release of nicotine from three commercial patches was measured for 24 hours under nine experimental conditions which were classified depending on the apparatus (i.e., paddle over disk, cylinder and reciprocating holder) and dissolution media (i.e., phosphate buffer pH 7.4, water and the 1 % phosphoric acid pH 1.5). In vitro permeation of nicotine from the patches across the human cadaver skin was also measured using a diffusion cell. The release of nicotine was better explained by the Higuchi's equation rather than by the first order rate equation. Correlation between the release rate and the in vitro skin permeation differed among the patches. However, in general, the cylinder method, in which water is used as a dissolution medium, showed the highest correlation among the nine release test conditions.

  • PDF

Mechanical Properties of Trabecular Bone in femoral Head & Neck (넙다리뼈 머리/목 부분 해면뼈의 기계적 물성)

  • Kwak Dai-Soon;Choi Kwang-Nam;Kim Sang-Kuk;Lee Sang-Ho;Kim Tae-Joong;Han Seung-Ho;Oh T.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.518-521
    • /
    • 2005
  • We performed the mechanical test for obtaining properties of femoral head. Tested sample was male and 35 years old. We measured bone mineral density by dual X-ray absorption method(DEXA). Results of DEXA, he has normal condition of bone density. His BMD $1.159g/cm^2$ and T-Score is 1.6. Tested femurs were harvested by surgical method from donated cadaver. We made 9 specimens in femoral head, 8 specimens in neck used by diamond core drill. Then we performed compressive test in saline solution at $38^{\circ}C$. We obtained results that elastic modulus of femoral head was 0.439GPa, neck was 0.459GPa. Compressive strength of femoral head was 7.441 MPa, neck was 7.095MPa. There was no significant difference of mechanical properties between left and right femoral head & neck. Invested local properties of femoral head have more strength superior and anterior side, femoral neck has more strength in superior and inferior side but other side except for superior has more weakness along the lateral side.

  • PDF

Biodynamic Characteristics of Korean Male in Twenties-Mass, Center of Mass and Moment of Inertia Characteristics of Body Segments (한국인 20대 청년 인체분절의 관성특성에 관한 연구)

  • 이영신;임현균;김철중
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.1952-1966
    • /
    • 1994
  • The body segment parameters of twelve young male Korean were measured to compare with the results of foreign cadaver studies. A human body was assumed to have fourteen body segments. The mass of each segment was measured with a water immersion test and the mass center of a segment was determined on the balance platform by changing postures. In the case of Korean, because of the difference in body proportion, the mass center of whole-body is located further from the distal end of head(Korean : 44.9% vs. Caucasian : 41.2%), and the mass center of each segment also located in different proportional locations. The existing regression equations, which can estimate segment mass based upon the anthropometric dimensions, estimates segment mass (the mass of shank) for Korean with 13% error. Therefore, it is not recommended to estimate the mass, and the moment of inertia of body segment of Korean based on the existing equations. However, the density information of body constituents was similar enough to apply it to Korean density. It was validated by the comparison between the results of the direct immersion method and 3-dimensional volume reconstruction of segment form the cross sectional images of CT-scan. The average body density measured form twelve subjects was $1.035{\;}kg/m^3$ and showed deceasing trendency.

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

Comparison of Three Different Techniques in Cervical Transpedicular Screw Insertion

  • Seo, Young-Jun;Song, Geun-Sung;Cho, Won-Ho;Choi, Byung-Kwan;Cha, Seung-Heon;Baek, Sun-Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.5
    • /
    • pp.360-365
    • /
    • 2006
  • Objective : This is a cadaver study to assess the accuracy of three cervical screw insertion techniques; the blind technique [Group I], the laminotomy technique [Group II], and the funnel technique [Group III]. Methods : Ten human cadavers embalmed with formaldehyde were prepared. After exposing the spinous processes, the laminas and the lateral masses, titanium alloy transpedicular screws were inserted from C3 to C7. A total of 100 pedicles were ramdomly assigned to one of three techniques [the blind technique : 31 screws, the laminotomy technique : 51 screws, the funnel technique: 18 screws]. Axial computed tomography with 1-mm slices, and sagittal and coronal reformation were performed to identify the accuracy of the screw insertion and the anatomic relationships. Results : In Group I, 9 screws [29%] were either contained within or penetrated less than 1mm, which were rated as successful. In Group II, 24 screws [47%] were successful. In Group III, 16 screws [89%] were successful. In the multiple comparison, there was a statistically significant difference between Groups I and III and between Groups II and III [$X^2$ test and Bonfenoni test]. Conclusion : The funnel technique can help a surgeon's understanding about the cervical pedicle more precisely than the other two techniques. The funnel technique is less dependent on lateral soft tissue retraction state.

Stability Test of Artificial Joint for Hip Joint (고관절용 인공관절 시스템의 안정성 평가)

  • Seok, Sung-Fie;Park, Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1033-1039
    • /
    • 2012
  • Artificial joints are used when joints lose their function because of either the destruction or damage of the composing bones of the joints. To evaluate the primary stability of a femur-implant system, the relative displacement caused by a repeated load is measured immediately after the insertion of the artificial joint. For more accurate stability evaluation, the accurate measurement of the penetration displacement of the artificial joint to the bone and the rotation angle of the artificial joint is essential. In this study, to evaluate the primary stability of the femur-implant system, we propose a new relative displacement measurement method. By using this new method, we comparatively evaluate the primary stability for various surgical methods and the varying stiffness of the cadaver femur-implant itself.

Experimental Verification of Implantable Middle Ear System using the Differential Electromagnetic Type Transducer (차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 실험적 검증)

  • 송병섭;이기찬;원철호;박세광;이상흔;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The implantable middle ear(IME) system, which has good sound quality. superior sound intelligibility and wide frequency characteristics. can resolve the sound distortion and ringing effect by sound feedback at high gain operation those are the major problems of conventional hearing aid. In this paper, we have manufactured the IME system using differential electromagnetic transducer(DET) and verified the performance of the system by carrying out vibration and animal implanting experiment. The DET was manufactured using micro-machining technology and vibration experiment of the transducer was performed to inspect whether the transducer could vibrate in accordance with the applied sound signal or not. And the result of the loaded experiment using temporal bone sampled from cadaver showed that the transducer can drive the middle ear bone and transmit the signal to inner ear After the internal unit of IME system was implanted in a dog. the auditory brainstem response (ABR) test was carried out. The result of the test indicated the Proper behavior of the IME system in the living body From the results of the experiments, it is verified that the manufactured system ewll work well when it is applied to human and a basis of clinical experiment of IME system to real human hearing impaired was be arranged.

Video Assisted Thoracoscopic Sympathetic Ramus Clipping in Essential Hyperhidrosis -Cadaver Fitting Test and Clinical Application (다한증 환자에서 클립을 이용한 교감신경 교통가지 차단술 -사체 연구 및 임상적용-)

  • Lee, Sung-Ho;Cho, Seong-Joon;Jung, Jae-Seung;Kim, Tae-Sik;Son, Ho-Sung;Sun, Kyung;Kim, Kwang-Taik;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.595-601
    • /
    • 2003
  • Background: It has been known that the most effective treatment method of hyperhidrosis is video-assisted thoracoscopic sympathetic nerve block. Postoperative compensatory hyperhidrosis and anhidrosis are major factors that decrease the postoperative satisfaction. Although sympathetic rami have been selectively blocked to decrease the complications, technical difficulties and excessive bleeding have prevented the universal application. Material and Method: Three pre-fixative cadavers were dissected before clinical application. Bilateral sympathetic chains were exposed in supine position after the whole anterior chest wall was removed. Second and third sympathetic rami were blocked using clips. After the sympathetic chains including ganglia were removed, we evaluated the extents of rami block. Twenty-five patients were subjected to the clinical application. Surgeries were performed in semi-fowlers position under general anesthesia and bilateral ventilation. 2 mm thoracoscopy and 5 mm trocar were intro-duced through third and fourth intercostal space, respectively. Second and third sympathetic rami were blocked using thoracoscopic clips. The postoperative complications, satisfaction, and compensatory hyperhidrosis rate were evaluated retrospectively. Result: Sympathetic rami were completely blocked in cadaver dissection study Hyper-hidrosis symptom was improved in all patients without operative complication. Operative time was shorter than that of traditional ramicotomy. All patients, except four, were satisfied with postoperative palmar hyperhidrosis. Com-pensatory hyperhidrosis was more severely happened in fifteen patients (60%). The remaining six patients had no complaint. Two patients had a minimal degree of gustatory hyperhidrosis. Conclusion: This operative method had shorter operative time and less complication rate, compared with traditional ramicotomy Operative success rate was similar to the traditional syrnpathicotorny; lower extent and occurrence rate of compensatory hyperhidrosis. The thoracic sympathetic rami clipping was suggested as an alternative method for treatment of palmar hyperhidrosis.